Siemens 3RT2025-1BB40 3RT2 17A 3P 400V Contactor
Siemens 3RT2025-1AP00 3RT2 17A 3P 400V Contactor
Siemens 3RT2024-2BB40 3RT2 12A 3P 400V Contactor
Siemens 3RT2024-2AP00 3RT2 12A 3P 400V Contactor
Siemens 3RT2024-1BB40 3RT2 12A 3P 400V Contactor
Siemens 3RT2024-1AP00 3RT2 12A 3P 400V Contactor
Siemens 3RT2023-2BB40 3RT2 9A 3P 400V Contactor
Siemens 3RT2023-2AP00 3RT2 9A 3P 400V Contactor
Siemens 3RT2023-1BB40 3RT2 9A 3P 400V Contactor
Siemens 3RT2023-1AP00 3RT2 9A 3P 400V Contactor
Siemens 3RT2018-2BB42 3RT2 16A 3P 400V Contactor
Siemens 3RT2018-2BB41 3RT2 16A 3P 400V Contactor
Siemens 3RT2018-2AP02 3RT2 16A 3P 400V Contactor
Siemens 3RT2018-2AP01 3RT2 16A 3P 400V Contactor
Siemens 3RT2018-1BB42 3RT2 16A 3P 400V Contactor
Siemens 3RT2018-1BB41 3RT2 16A 3P 400V Contactor
Siemens 3RT2018-1AP02 3RT2 16A 3P 400V Contactor
Siemens 3RT2018-1AP01 3RT2 16A 3P 400V Contactor
Siemens 3RT2017-2BB42 3RT2 12A 3P 400V Contactor
Siemens 3RT2017-2BB41 3RT2 12A 3P 400V Contactor
Power contactors (AC-3) from ABB, Schneider Electric and Siemens start and stop three-phase motors and switch heavy loads. The range covers over 650 products from 6 A to 2650 A, with motor ratings from 2.2 kW to 450 kW, mostly in 3 and 4 pole versions. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- ABB AF Contactors – 3 and 4 pole AF series with wide-range AC/DC coils.
- Schneider TeSys Deca Contactors – the largest series here, from 9 A to 200 A.
- Schneider TeSys Giga Contactors – high-current frames from 115 A to 800 A.
- Schneider TeSys K Contactors – compact contactors for 6 A to 16 A.
- Schneider Easy TeSys Contactors – general-purpose contactors from 6 A to 630 A.
- Siemens SIRIUS 3RT2 Contactors and Siemens SIRIUS 3RT1 Contactors – SIRIUS frames from small to very large.
How to choose
- Motor power and current in AC-3 at your supply voltage. Do not size from the AC-1 value.
- Pole count: 3P for motors, 4P where the neutral is switched.
- Coil voltage and type, AC or DC, against the control supply.
- Short-circuit protection and overload relay matched to the contactor, following the manufacturer's coordination tables.
- Auxiliary contact needs and whether add-on blocks fit the frame.
FAQ
What does AC-3 mean on a contactor?
AC-3 is the IEC 60947-4-1 category for starting and stopping squirrel-cage motors. Ratings in AC-3 are usually lower than AC-1 for the same frame.
Can I replace a contactor with another brand?
Check rated current in AC-3, pole count, coil voltage and mounting dimensions. Auxiliary contacts and coordination with the overload relay must also match.
Do you ship contactors outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.