- Home
- All Collections
- RCD Add-on Blocks & Earth Leakage Relays
RCD Add-on Blocks & Earth Leakage Relays
RCD Add-on Blocks & Earth Leakage Relays
Siemens 5SV8900-1KK 5SV8 Residual Current Device
Siemens 5SV8706-0KK 5SV8 630A Residual Current Device
Siemens 5SV8702-0KK 5SV8 80A Residual Current Device
Siemens 5SV8001-6KK 5SV8 0.03A 230V Residual Current Device
Siemens 5SV8704-0KK 5SV8 250A Residual Current Device
Siemens 5SV8000-6KK 5SV8 0.03A 230V Residual Current Device
Siemens 5SV8705-0KK 5SV8 500A Residual Current Device
Siemens 5SV8703-0KK 5SV8 200A Residual Current Device
Schneider Electric A9R41425 iID 4P 25A 10kA 400/415V AC Earth Leakage Protection RCCB DIN Rail
Schneider Electric LV481010 Vigirex RHB Type B 30 mA-3 A 100-250 V AC/DC Residual Current Monitoring Relay
Schneider Electric LV481004 Vigirex RMH 30 mA-30 A 220-240 V AC Multiplexed Residual Current Monitoring Relay
Schneider Electric LV481003 Vigirex RHU Modbus 30 mA-30 A 220-240 V AC Residual Current Monitoring Relay
Schneider Electric LV481001 Vigirex RHUs 30 mA-30 A 0-4.5 s 220-240 V AC Residual Current Monitoring Relay
ABB 2CSJ203001R0002 RD3P 500mA 230-400V AC DIN-Rail Residual Current Monitoring Relay
ABB 2CSJ202001R0002 RD3M 1-500mA 230-400V AC DIN-Rail Residual Current Monitoring Relay
ABB 2CSJ201001R0002 RD3 Type A 500mA 230-400V AC 3.6W Residual Current Monitor
ABB 2CSM142120R1201 RD2 Type A 2000mA 230-400V AC DIN-Rail Residual Current Monitoring Relay
ABB 2CSB204001R3400 DDA204 AC-40/0.3 4P 40A 300mA Type AC Residual Current Circuit Breaker Module
ABB 2CSB204001R1630 DDA204 AC-63/0.03 4P 63A 30mA Type AC Residual Current Circuit Breaker Module
ABB 2CSB204001R1400 DDA204 AC-40/0.03 4P 40A 30mA Type AC Residual Current Circuit Breaker Module
RCD add-on blocks and earth leakage relays from ABB and Schneider Electric add residual current protection to existing MCBs or monitor leakage on a panel. The range includes ABB DDA200 blocks in 2, 3 and 4 poles from 25 A to 63 A, ABB RD2 and RD3 monitoring relays and Schneider Electric Acti9 blocks. Stoklink ships worldwide from Turkey.
What's in this range
- ABB DDA200 RCD blocks that mount on S200 series MCBs, in 2P, 3P and 4P.
- ABB RD2 and RD3 residual current monitoring relays for use with a separate toroid.
- Schneider Electric Acti9 add-on blocks.
How to choose
- Compatibility: the block must match the MCB series, pole count and rated current.
- Function: a block trips the MCB. A relay only signals or trips through a separate device.
- Type: AC or A for the load.
FAQ
Can an RCD block be fitted to any MCB?
No. Use the block specified for the MCB series and pole count. Mixing brands or series is not covered by the manufacturer.
What does a residual current monitoring relay do?
It measures leakage current through a toroid and gives an alarm or trip signal at an adjustable threshold. It does not interrupt the circuit by itself.
Do you ship these to export markets?
Yes. Stoklink ships from Turkey, EXW, and quotes project quantities on request.