- Home
- All Collections
- Power Contactors (AC-3)
Power Contactors (AC-3)
Siemens 3RT2038-1AP00 3RT2 80A 3P 400V Contactor
Siemens 3RT2037-1NB30 3RT2 65A 3P 400V Contactor
Siemens 3RT2037-1AP00 3RT2 65A 3P 400V Contactor
Siemens 3RT2036-1NB30 3RT2 51A 3P 400V Contactor
Siemens 3RT2036-1AP00 3RT2 51A 3P 400V Contactor
Siemens 3RT2035-1NB30 3RT2 41A 3P 400V Contactor
Siemens 3RT2035-1AP00 3RT2 41A 3P 400V Contactor
Siemens 3RT2028-2BB40 3RT2 38A 3P 400V Contactor
Siemens 3RT2028-2AP00 3RT2 38A 3P 400V Contactor
Siemens 3RT2028-1BB40 3RT2 38A 3P 400V Contactor
Siemens 3RT2028-1AP00 3RT2 38A 3P 400V Contactor
Siemens 3RT2027-2BB40 3RT2 32A 3P 400V Contactor
Siemens 3RT2027-2AP00 3RT2 32A 3P 400V Contactor
Siemens 3RT2027-1BB40 3RT2 32A 3P 400V Contactor
Siemens 3RT2027-1AP00 3RT2 32A 3P 400V Contactor
Siemens 3RT2026-2BB40 3RT2 25A 3P 400V Contactor
Siemens 3RT2026-2AP00 3RT2 25A 3P 400V Contactor
Siemens 3RT2026-1BB40 3RT2 25A 3P 400V Contactor
Siemens 3RT2025-2BB40 3RT2 17A 3P 400V Contactor
Siemens 3RT2025-2AP00 3RT2 17A 3P 400V Contactor
Power contactors (AC-3) from ABB, Schneider Electric and Siemens start and stop three-phase motors and switch heavy loads. The range covers over 650 products from 6 A to 2650 A, with motor ratings from 2.2 kW to 450 kW, mostly in 3 and 4 pole versions. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- ABB AF Contactors – 3 and 4 pole AF series with wide-range AC/DC coils.
- Schneider TeSys Deca Contactors – the largest series here, from 9 A to 200 A.
- Schneider TeSys Giga Contactors – high-current frames from 115 A to 800 A.
- Schneider TeSys K Contactors – compact contactors for 6 A to 16 A.
- Schneider Easy TeSys Contactors – general-purpose contactors from 6 A to 630 A.
- Siemens SIRIUS 3RT2 Contactors and Siemens SIRIUS 3RT1 Contactors – SIRIUS frames from small to very large.
How to choose
- Motor power and current in AC-3 at your supply voltage. Do not size from the AC-1 value.
- Pole count: 3P for motors, 4P where the neutral is switched.
- Coil voltage and type, AC or DC, against the control supply.
- Short-circuit protection and overload relay matched to the contactor, following the manufacturer's coordination tables.
- Auxiliary contact needs and whether add-on blocks fit the frame.
FAQ
What does AC-3 mean on a contactor?
AC-3 is the IEC 60947-4-1 category for starting and stopping squirrel-cage motors. Ratings in AC-3 are usually lower than AC-1 for the same frame.
Can I replace a contactor with another brand?
Check rated current in AC-3, pole count, coil voltage and mounting dimensions. Auxiliary contacts and coordination with the overload relay must also match.
Do you ship contactors outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.