Contactors for Data Center PDU and UPS Systems: Selection Guide
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
The ABB UA63-30-00RA 220-230V50Hz/230-240V60Hz contactor (SKU: 1SBL371024R8000) is a 3-pole power contactor from ABB's UA Series, designed for reliable motor switching and load control in industrial environments. Operating on a 220–230 V 50 Hz / 230–240 V 60 Hz control coil voltage, this contactor is well-suited for AC motor starter applications demanding robust performance and international compliance.
| Product Net Width | 70 mm |
|---|---|
| Product Net Depth / Length | 140.4 mm |
| Product Net Height | 150 mm |
| Product Net Weight | 1.35 kg |
| Number of Main Contacts NO | 3 |
|---|---|
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Standards | IEC/EN 60947-1, IEC/EN 60947-4-1 |
| Rated Operational Voltage | Main Circuit 690 V |
| Rated Frequency (f) | Control Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz |
| Rated Operational Power AC-6b (Pe) | (230 / 240 V) 40 °C, 50 / 60 Hz 30 kvar, (230 / 240 V) 55 °C, 50 / 60 Hz 27 kvar, (230 / 240 V) 70 °C, 50 / 60 Hz 23 kvar, (400 / 415 V) 40 °C, 50 / 60 Hz 50 kvar, (400 / 415 V) 70 °C, 50 / 60 Hz 39 kvar, (400 / 415 V) 55 °C, 50 / 60 Hz 45 kvar, (440 V) 40 °C, 50 / 60 Hz 55 kvar, (440 V) 55 °C, 50 / 60 Hz 48 kvar, (440 V) 70 °C, 50 / 60 Hz 42.5 kvar, (500 / 550 V), 40 °C, 50 / 60 Hz 65 kvar, (500 / 550 V) 55 °C, 50 / 60 Hz 60 kvar, (500 / 550 V) 70 °C, 50 / 60 Hz 50 kvar, (690 V) 40 °C, 50 / 60 Hz 80 kvar, (690 V) 55 °C, 50 / 60 Hz 75 kvar, (690 V) 70 °C, 50 / 60 Hz 65 kvar |
| Short-Circuit Protective Devices | gG Type Fuses 200 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 1000 V, acc. to UL/CSA 600 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Electrical Durability | Ue =< 440 V 250000 cycle, Ue = 500 ... 690 V 100000 cycle |
| Maximum Electrical Switching Frequency | 240 cycles per hour |
| Rated Control Circuit Voltage (Uc) | 50 Hz 220 ... 230 V, 60 Hz 230 ... 240 V |
| Coil Consumption | Average Holding Value 50 / 60 Hz 18 V·A, Average Holding Value 50 Hz 18 V·A, Average Holding Value 60 Hz 18 V·A, Average Pull-in Value 50 Hz 180 V·A, Average Pull-in Value 60 Hz 210 V·A |
| Operate Time | Between Coil De-energization and NO Contact Opening 4 ... 11 ms, Between Coil Energization and NO Contact Closing 8 ... 27 ms |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715, TH75-25 (75 x 25 mm Mounting Rail) acc. to IEC 60715 |
| Mounting by Screws (not supplied) | 2 x M6 Screws Placed Diagonally |
| Connecting Capacity Main Circuit | Flexible with Cable End 6 ... 10 mm², Rigid Cable 6 ... 16 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Cable End 0.75 ... 2.5 mm², Rigid Cable 1 ... 4 mm² |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 |
| Connecting Terminals (delivered in open position) Main Poles | M 6 (+,-) pozidriv 2 screws with 1x (13 x 10 mm) connector |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
| Ambient Air Temperature | Close to Contactor for Storage -60 ... +80 °C, Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C, Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C |
|---|---|
| Climatic Withstand | according to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Pollution Degree | 3 |
| Part number | 1SBL371024R8000 |
|---|---|
| Type designation | UA63-30-00RA |
| Brand | ABB |
| Condition | New, factory sealed |
| Source | ABB and its authorised distributors |
| Warranty | Manufacturer warranty |
| EAN | 3471522304803 |
| eCl@ss | 27371006 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| REACH Declaration | 2CMT2021-006202 |
|---|---|
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 52581adc-09f9-4f5b-b05b-62ca78820edf Bulgaria |
| Simplified SCIP | 0dc7f8e0-36ed-4ef0-a410-d25430c81518 Denmark, 111be1b0-4cea-4704-a7a1-c2aeb71e6c53 Norway, 25b3f4ac-71f2-4fcd-8cf8-e583954dedd1 Poland, 33960ef5-92af-4501-8f9c-4e454abcaa86 Finland, 383073d9-7aa9-40ea-838c-8fb8fe4e44bf Belgium, 40a32b38-e260-4fbb-83a8-cf13d6a8fd09 Portugal, 5d8e6ace-1d8e-4764-8b2d-dce659ec76d8 Czechia, 6e77e4f7-330c-42cc-a51b-cddd124afff2 Belgium, 72e0f640-d623-44fb-960b-7e3050615139 Poland, 74fb4c31-9f63-4bb5-874b-ffdb53988112 Germany, 91b972e0-8d5d-48bf-b7f3-f45bcd891d10 Germany, 98a81e71-2ba0-4858-8880-c19f60c7eaab Sweden, 9d8ac94e-fa9b-43b9-87e1-56563afd1468 Croatia, a12414b2-4f88-4fc0-8a4a-f54b28719834 Estonia, a96bb407-9457-4b22-99a5-255e99a48c46 Italy, b49350b5-b4cd-4325-92c0-574d6cb1f93f Hungary, b727e65d-02e3-489c-ac4c-1d8a924a8618 Germany, bf1bbf4d-c4a8-455a-a0bb-fa59d4f0b0ee France, c732d74d-9c75-4e2d-97fa-7bc1ff6e3894 Netherlands, c8ff5f53-81a4-4951-9af1-b32aca7982cb France, cbbd5111-24ae-400a-8174-7e8fff11d64a Greece, cc7f61da-6706-4921-93d4-28f6c9f05128 Hungary, d389f2a7-0104-4fb3-ad52-46c3cec78772 Sweden, ea3d85c3-bdca-4da4-ac41-150b16426e0a Spain, f305662d-a47a-446a-b580-cb8d2a36ac57 Germany, f441aef3-5b0f-47b7-80ff-68f43908e755 Poland, fa6fd1c7-c9fb-44fd-ad13-61973957e016 Germany |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ETIM 7 | EC001079 - Capacitor contactor |
|---|---|
| eClass | V11.0 : 27371006 |
| UNSPSC | 39121529 |
| Package Level 1 Units | box 1 piece |
|---|---|
| Package Level 1 Width | 160 mm |
| Package Level 1 Depth / Length | 200 mm |
| Package Level 1 Height | 85 mm |
| Package Level 1 Gross Weight | 1.35 kg |
| Package Level 1 EAN | 3471522304803 |
| Shipping weight | 1.35 kg |
| Ships from | Türkiye |
| Dispatch | 9 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe tariff (HS) code on file for UA63-30-00RA is 85364900.
The EAN (GTIN) of UA63-30-00RA is 3471522304803.
UA63-30-00RA ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
Compare AC3 rating IEC contactors versus NEMA size codes, with cross-reference tables, derating formulas, and selection tips for engineers. Shop at Stoklink.
Master AC3 rating selection with our complete contactor checklist covering load sizing, utilization categories, derating, and coordination. Shop at Stoklink.