- Home
- All Collections
- Residual Current Devices (RCD)
Residual Current Devices (RCD)
Siemens 5SU1353-1KK20 5SU1 20A 2P 230V Residual Current Breaker (RCBO)
Schneider Electric A9R61440 iID 4P 40A Residual Current Circuit Breaker (RCCB) Acti9
ABB 2CSF204001R1630 F204 AC-63/0.03 4P 63A 30mA Type AC Residual Current Circuit Breaker
ABB 2CSF202201R3630 F202 A S-63/0.3 2P 63A 300mA Type A Residual Current Circuit Breaker
ABB 2CSF202201R3400 F202 A S-40/0.3 2P 40A 300mA DIN-Rail Residual Current Circuit Breaker (RCCB)
ABB 2CSF204001R3950 F204 AC-125/0.3 4P 125A 300mA 10kA Residual Current Circuit Breaker
ABB 2CSF204001R3800 F204 AC-80/0.3 4P 80A Residual Current Circuit Breaker (RCCB) DIN Rail
ABB 2CSR255080R1324 DS201 C32 AC30 1P+N 32A 10kA RCBO Residual Current Circuit Breaker with Overcurrent Protection
ABB 2CSR255080R1254 DS201 C25 AC30 1P+N 25A 10kA RCBO Residual Current Circuit Breaker with Overcurrent Protection
Siemens 5SU1653-1KK40 5SU1 40A 2P 230V Residual Current Breaker (RCBO)
Siemens 5SU1653-1KK32 5SU1 32A 2P 230V Residual Current Breaker (RCBO)
Siemens 5SU1653-1KK25 5SU1 25A 2P 230V Residual Current Breaker (RCBO)
Siemens 5SU1653-1KK20 5SU1 20A 2P 230V Residual Current Breaker (RCBO)
Siemens 5SU1653-1KK16 5SU1 16A 2P 230V Residual Current Breaker (RCBO)
Siemens 5SU1653-1KK10 5SU1 10A 2P 230V Residual Current Breaker (RCBO)
Siemens 5SU1653-1KK06 5SU1 6A 2P 230V Residual Current Breaker (RCBO)
Siemens 5SU1646-7FP32 5SU1 32A 4P 400V Residual Current Breaker (RCBO)
Siemens 5SU1646-7FP25 5SU1 25A 4P 400V Residual Current Breaker (RCBO)
Siemens 5SU1646-7FP20 5SU1 20A 4P 400V Residual Current Breaker (RCBO)
Siemens 5SU1646-7FP16 5SU1 16A 4P 400V Residual Current Breaker (RCBO)
Residual current devices (RCD) from ABB, Siemens and Schneider Electric detect earth leakage and disconnect the circuit before it becomes a shock or fire risk. The range covers RCCBs, RCBOs and add-on blocks in 1+N, 2, 3 and 4 poles, with sensitivities from 30 mA to 300 mA. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- RCCB (Residual Current Circuit Breakers) – earth leakage protection only, used with an upstream MCB or fuse.
- RCBO (Residual Current Breakers with Overcurrent Protection) – leakage, overload and short-circuit protection in one device.
- RCD Add-on Blocks & Earth Leakage Relays – blocks that clip onto an MCB, and relays for leakage monitoring.
How to choose
- Sensitivity: 30 mA for personal protection, 100 to 300 mA for fire protection and selectivity.
- Type: AC, A or B, depending on whether the load can produce pulsating or smooth DC leakage, as with drives and inverters.
- Rated current and poles: the RCD must carry the total load of the circuits behind it. Match 2P to single-phase and 4P to three-phase with neutral.
- Standard: IEC 61008-1 for RCCBs and IEC 61009-1 for RCBOs.
- Selectivity: use a time-delayed or S-type RCD upstream of an instantaneous one.
FAQ
What is the difference between an RCCB and an RCBO?
An RCCB only detects earth leakage, so it needs a separate MCB or fuse for overload and short-circuit protection. An RCBO combines both in one module.
Which RCD type do I need for a variable frequency drive?
Drives can produce DC leakage components that Type AC and Type A devices may not detect. Type B is normally specified for three-phase drive circuits. Check the drive manual.
Do you ship RCDs outside Turkey?
Yes. Stoklink ships worldwide from Turkey, EXW. Lead time depends on distributor stock, and we quote bulk project volumes on request.