Categories
No result found for your search.
Need help? Contact us
+90 542 203 61013
info@stoklink.com
Your cart is empty
- Home
- All Collections
- ABB Basic M MCBs
Filter
ABB Basic M MCBs
ABB 2CDS631031R0104 BMS311C10 1P 10A 3kA Curve C DIN Rail Miniature Circuit Breaker
ABB 2CDS631031R0164 BMS311C16 1P 16A 3kA Curve-C Basic M BMS Miniature Circuit Breaker
ABB 2CDS654061R0404 BMS614C40 4P 40A 6kA C-Curve Miniature Circuit Breaker
ABB 2CDS654061R0324 BMS614C32 4P 32A 6kA 400V AC Miniature Circuit Breaker
ABB 2CDS654061R0204 BMS614C20 4P 20A 6kA 400V AC DIN Rail Miniature Circuit Breaker
ABB 2CDS653061R0254 BMS613C25 3P 25A 6kA 400V AC Miniature Circuit Breaker
ABB 2CDS653061R0324 BMS613C32 3P 32A 6kA 400V AC Miniature Circuit Breaker
ABB 2CDS654061R0104 BMS614C10 4P 10A 500V DC 10kA Miniature Circuit Breaker
ABB 2CDS653061R0404 BMS613C40 3P 40A 6kA 400V AC Miniature Circuit Breaker
ABB 2CDS653061R0204 BMS613C20 3P 20A 6kA 400V AC Miniature Circuit Breaker
ABB 2CDS654061R0064 BMS614C06 4P 6A 10kA 500V DC Miniature Circuit Breaker
ABB 2CDS653061R0104 BMS613C10 3P 10A 6kA C-Curve 400V Miniature Circuit Breaker
ABB 2CDS652061R0404 BMS612C40 2P 40A 6kA 400V AC C-Curve DIN Rail Miniature Circuit Breaker
ABB 2CDS653061R0064 BMS613C06 3P 6A 6kA 400V AC Miniature Circuit Breaker
ABB 2CDS651061R0324 BMS611C32 1P 32A 6kA Curve-C Miniature Circuit Breaker
ABB 2CDS651061R0254 BMS611C25 1P 25A 6kA C-Curve 230V Miniature Circuit Breaker
ABB 2CDS651061R0404 BMS611C40 1P 40A 6kA 230V Miniature Circuit Breaker
ABB 2CDS651061R0204 BMS611C20 1P 20A 6kA C-Curve DIN Rail Miniature Circuit Breaker
ABB 2CDS651061R0164 BMS611C16 1P 16A 6kA C-Curve DIN Rail Miniature Circuit Breaker
ABB 2CDS653061R0065 BMS613B06 3P 6A 10kA 480Y/277V AC 500V DC Miniature Circuit Breaker
ABB Basic M MCBs are entry-level DIN-rail miniature circuit breakers with a 3 kA breaking capacity. The range covers 6 A to 63 A in 1, 2, 3 and 4 poles, with more than 80 products. Stoklink ships worldwide from Turkey and quotes volumes on request.
What's in this range
- BMS311, BMS313 and BMS314 types for 1P, 3P and 4P circuits.
- B and C curve versions at 230 V and 400 V AC.
- For higher fault levels see ABB System pro M compact S200 MCBs.
How to choose
- 3 kA breaking capacity suits only installations with a low prospective short-circuit current. Check it first.
- Select the curve from the load: B for resistive circuits, C for general loads.
- Select the rating from the cable and the pole count from the supply system.
FAQ
Where is a 3 kA MCB acceptable?
In small installations where the calculated fault current at the board is below 3 kA. Higher fault levels need a 6 kA or 10 kA breaker.
What do the letters in BMS311C32 mean?
BMS311 is the series and pole count, C is the curve and 32 is the rated current in amperes.
Can I order Basic M breakers in bulk?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.