Filter
Brand
Product Series
Rated Current (Amphere)
Brand
Product Series
Rated Current (Amphere)

Air Circuit Breakers (ACB)

Filter
Showing 1 - 20 of 404 items

ABB 1SDA071061R1 E2.2N 2500 Ekip Dip LI 3p F HR 2500A 3P 66kA Fixed Power Circuit Breaker

Free Shipping
ABB 1SDA071061R1 E2.2N 2500 Ekip Dip LI 3p F HR
Reference No: 1SDA071061R1
Catalog No: E2.2N 2500 Ekip Dip LI 3p F HR
Rated Current (A): 2500 A
Breaking Capacity (kA): (400 V AC) 66 kA
Number of Poles: 3
158 pcs in stock
$4,234.29

ABB 1SDA071032R1 E2.2N 2000 Ekip Dip LSI 3p F HR 2000A 3P 66kA Fixed Air Circuit Breaker

Free Shipping
ABB 1SDA071032R1 E2.2N 2000 Ekip Dip LSI 3p F HR
Reference No: 1SDA071032R1
Catalog No: E2.2N 2000 Ekip Dip LSI 3p F HR
Rated Current (A): 2000 A
Breaking Capacity (kA): (400 V AC) 66 kA
Number of Poles: 3
24 pcs in stock
$3,530.53

ABB 1SDA073700R1 YU E1.2..E6.2-XT7-XT7M 220-240 VAC/DC Undervoltage Release

Reference No: 1SDA073700R1
Catalog No: YU E1.2..E6.2-XT7-XT7M 220-240 VAC/DC
515 pcs in stock
$115.30

ABB 1SDA071062R1 E2.2N 2500 Ekip Dip LSI 3p F HR 2500A 3P 66kA Fixed Power Circuit Breaker

Free Shipping
ABB 1SDA071062R1 E2.2N 2500 Ekip Dip LSI 3p F HR
Reference No: 1SDA071062R1
Catalog No: E2.2N 2500 Ekip Dip LSI 3p F HR
Rated Current (A): 2500 A
Breaking Capacity (kA): (400 V AC) 66 kA
Number of Poles: 3
32 pcs in stock
$4,366.53

ABB 1SDA073762R1 AUP 6 contacts 400Vac E1.2-XT7-XT7M Accessory for Air Circuit Breaker (Position Contacts)

Reference No: 1SDA073762R1
Catalog No: AUP 6 contacts 400Vac E1.2-XT7-XT7M
2 pcs in stock
$256.85

ABB 1SDA073911R1 E2.2 W FP Iu=2500 3p HR HR 2500A 3-Pole Withdrawable Chassis Part Power Circuit Breaker

Reference No: 1SDA073911R1
Catalog No: E2.2 W FP Iu=2500 3p HR HR
Rated Current (A): 2500 A
Number of Poles: 3
11 pcs in stock
$779.49

ABB 1SDA066150R1 AUX-C 2Q+1SY 250 Va.c/d.c. A1-A2 3p-4p Auxiliary Contact Accessory for Circuit Breaker

Reference No: 1SDA066150R1
Catalog No: AUX-C 2Q+1SY 250 Va.c/d.c. A1-A2 3p-4p
Number of Poles: 3p-4p
24 pcs in stock
$40.90

ABB 1SDA072411R1 E2.2N 2500 Ekip Dip LI 3p WMP 2500A 3P 66kA Withdrawable Power Circuit Breaker

Free Shipping
ABB 1SDA072411R1 E2.2N 2500 Ekip Dip LI 3p WMP
Reference No: 1SDA072411R1
Catalog No: E2.2N 2500 Ekip Dip LI 3p WMP
Rated Current (A): 2500 A
Breaking Capacity (kA): (400 V AC) 66 kA
Number of Poles: 3
2 pcs in stock
$4,122.75

ABB 1SDA066561R1 A3N 400 TMF 400-4000 3p F F 400A 3-Pole Fixed Air Circuit Breaker

Reference No: 1SDA066561R1
Catalog No: A3N 400 TMF 400-4000 3p F F
Rated Current (A): 400 A
Breaking Capacity (kA): (400 V AC) 36 kA
Number of Poles: 3
666 pcs in stock
$310.61

ABB 1SDA071141R1 E4.2N 3200 Ekip Dip LI 3p F HR 3200A 3P 66kA Air Circuit Breaker

Free Shipping
ABB 1SDA071141R1 E4.2N 3200 Ekip Dip LI 3p F HR
Reference No: 1SDA071141R1
Catalog No: E4.2N 3200 Ekip Dip LI 3p F HR
Rated Current (A): 3200 A
Breaking Capacity (kA): (400 V AC) 66 kA
Number of Poles: 3
42 pcs in stock
$5,040.68

ABB 1SDA066564R1 A3N 630 TMF 500-5000 3p F F 500A 3-Pole Fixed Air Circuit Breaker

Reference No: 1SDA066564R1
Catalog No: A3N 630 TMF 500-5000 3p F F
Rated Current (A): 500 A
Breaking Capacity (kA): (400 V AC) 36 kA
Number of Poles: 3
152 pcs in stock
$348.17

ABB 1SDA071262R1 E6.2H 5000 Ekip Dip LSI 3p F HR 5000A 3P 100kA Power Circuit Breaker

Free Shipping
ABB 1SDA071262R1 E6.2H 5000 Ekip Dip LSI 3p F HR
Reference No: 1SDA071262R1
Catalog No: E6.2H 5000 Ekip Dip LSI 3p F HR
Rated Current (A): 5000 A
Breaking Capacity (kA): (400 V AC) 100 kA
Number of Poles: 3
0 pcs in stock
$10,965.67

ABB 1SDA073868R1 IP54 Flange key No. 20005 E1.2-XT7M Accessory for Air Circuit Breaker

Reference No: 1SDA073868R1
Catalog No: IP54 Flange key No. 20005 E1.2-XT7M
1 pcs in stock
$219.13

ABB 1SDA066786R1 A2N 250 TMF 250-2500 3p F F 250A 3-Pole Fixed Air Circuit Breaker

Reference No: 1SDA066786R1
Catalog No: A2N 250 TMF 250-2500 3p F F
Rated Current (A): 250 A
Breaking Capacity (kA): (400 V AC) 36 kA
Number of Poles: 3
1483 pcs in stock
$146.08

ABB 1SDA066784R1 A2N 250 TMF 200-2000 3p F F 200A 3-Pole Fixed Air Circuit Breaker

Reference No: 1SDA066784R1
Catalog No: A2N 250 TMF 200-2000 3p F F
Rated Current (A): 200 A
Breaking Capacity (kA): (400 V AC) 36 kA
Number of Poles: 3
772 pcs in stock
$129.78

ABB 1SDA071021R1 E2.2B 2000 Ekip Dip LI 3p F HR 2000A 3P 42kA Fixed Air Power Circuit Breaker

Free Shipping
ABB 1SDA071021R1 E2.2B 2000 Ekip Dip LI 3p F HR
Reference No: 1SDA071021R1
Catalog No: E2.2B 2000 Ekip Dip LI 3p F HR
Rated Current (A): 2000 A
Breaking Capacity (kA): (400 V AC) 42 kA
Number of Poles: 3
38 pcs in stock
$3,287.94

ABB 1SDA073914R1 E4.2 W FP Iu=3200 4p HR HR Chassis Part Power Circuit Breaker

Reference No: 1SDA073914R1
Catalog No: E4.2 W FP Iu=3200 4p HR HR Chassis Part
Number of Poles: 4
3 pcs in stock
$848.19

ABB 1SDA072342R1 E2.2N 1600 Ekip Dip LSI 3p WMP 1600A 3P 66kA Withdrawable Power Circuit Breaker

Free Shipping
ABB 1SDA072342R1 E2.2N 1600 Ekip Dip LSI 3p WMP
Reference No: 1SDA072342R1
Catalog No: E2.2N 1600 Ekip Dip LSI 3p WMP
Rated Current (A): 1600 A
Breaking Capacity (kA): (400 V AC) 66 kA
Number of Poles: 3
2 pcs in stock
$3,005.64

ABB 1SDA066566R1 A3N 630 ELT-LI In=630 3p F F 630A 3-Pole Fixed Air Circuit Breaker

Reference No: 1SDA066566R1
Catalog No: A3N 630 ELT-LI In=630 3p F F
Rated Current (A): 630 A
Breaking Capacity (kA): (400 V AC) 36 kA
Number of Poles: 3
536 pcs in stock
$357.76

ABB 1SDA073895R1 Support F/FP Type A,B,D E2.2–E6.2 Mechanical Interlock Support Accessory for Air Circuit Breaker

Reference No: 1SDA073895R1
Catalog No: Support F/FP Type A,B,D E2.2ΓçaE6.2
3 pcs in stock
$135.95

Air Circuit Breakers (ACB): Ultimate High-Capacity Protection up to ACB 4000A

Air Circuit Breakers (ACBs) are the backbone of electrical power distribution in large commercial, industrial, and utility applications. Serving as the primary protection device in main switchboards, the Air Circuit Breaker is engineered to manage and interrupt extremely high fault currents, often ranging up to 100kA or more. Known also simply as an Air Circuit Breaker, this device utilizes air as the arc-quenching medium, offering reliable safety for systems carrying massive load currents. At Stoklink, we supply top-tier industrial ACB units from world-class manufacturers, including the robust ABB Emax ACB, the sophisticated ACB Schneider MasterPact series, and the precision-engineered Siemens 3WL ACB.

Essential Industrial ACB Breaker Technology and Features

The structural integrity and advanced tripping mechanisms of the Air Circuit Breaker distinguish it from smaller protective devices. Unlike MCCBs, ACBs are typically designed to be modular and often withdrawable, allowing for easier maintenance, testing, and replacement without extended system downtime—a non-negotiable feature in high-power industrial environments.

Selecting ACB Breakers: Superior Current Ratings and Breaking Capacity up to ACB 4000A

The core strength of the ACB breaker lies in its massive current-handling capability. While moulded Case Circuit Breakers typically cap out around 1600A, Air Circuit Breakers routinely operate at higher nominal currents, ensuring protection for main incoming feeders. Stoklink offers a complete range of high-amperage Air Circuit Breaker options, supporting massive power demands. For extremely large facilities and main distribution points, the capacity can extend up to an impressive ACB 4000A or higher. This immense capacity, combined with very high short-circuit breaking capabilities, ensures that the breaker can safely and repeatedly interrupt severe electrical faults without damage to itself or the surrounding infrastructure. Selecting an ACB with a current rating that matches or exceeds peak operational demand is vital for system stability.

ACB vs MCCB Comparison: Choosing the Right Main Distribution Breaker

Understanding the distinction between an ACB vs MCCB is crucial in electrical system design. While both are used for overcurrent protection, they serve different operational tiers based on current and breaking capacity. moulded Case Circuit Breakers (MCCBs) handle intermediate currents and provide primary protection in sub-distribution boards or for large equipment feeders. They operate using fixed enclosures and generally employ thermal-magnetic or basic electronic trip units.

Air Circuit Breakers (ACBs), however, are deployed at the highest levels of the electrical network—at the point of power entry or primary busbar distribution. They manage much higher fault currents and nominal currents (up to 4000A or 6300A). ACBs always feature advanced electronic trip units, extensive connectivity options for energy management, and often utilize a robust, withdrawable design. If your requirement involves large-scale distribution or high fault currents, an Air Circuit Breaker is the necessary technology to protect your primary system.

Leading ACB Brands: ABB Emax ACB, Schneider MasterPact, and Siemens 3WL ACB Solutions

Global leaders in power management provide the most reliable ACB technology, each with signature features for distinct industrial requirements.

  • ABB Emax ACB: The ABB Emax ACB series, such as the Emax 2, is distinguished by its digital integration. These breakers go beyond protection, acting as smart power managers that monitor energy consumption and provide local and remote control, making them a crucial component for modern, connected industrial grids.

  • ACB Schneider MasterPact: The ACB Schneider MasterPact range, including the MasterPact MTZ series, is known for its advanced connectivity and digital modularity. Features often include embedded power meters and digital modules that allow for immediate upgrades and maintenance, enhancing operational flexibility and reducing maintenance complexity.

  • Siemens 3WL ACB: The Siemens 3WL ACB product family is engineered for flexibility and standardized integration across global applications. These breakers are known for their easy retrofitting capabilities and their comprehensive range of accessories and digital functionality, ensuring high performance and a compact footprint in switchgear assemblies.

Find ACB Breaker at Stoklink 

For mission-critical applications, large industrial plants, and main distribution infrastructure, the Air Circuit Breaker provides the definitive standard for high-capacity protection. Stoklink offers a superior range of ACB breaker products, supporting crucial functions and diverse current demands, including solutions up to ACB 4000A. Our inventory is backed by the innovation of ABB Emax ACB, the connectivity of ACB Schneider MasterPact, and the reliable engineering of Siemens 3WL ACB. You can also ensure the long-term resilience and safety of your most valuable electrical assets with Air Circuit Breaker collection at Stoklink.