Motor protection circuit breakers (MPCB) from ABB, Siemens and Schneider Electric combine short-circuit and overload protection for motor feeders. The range covers 0.16 A to 500 A in 3-pole versions, from small manual starters to large thermal-magnetic breakers. Stoklink ships worldwide from Turkey and quotes project volumes on request.
GV4PE115S Schneider Electric · Schneider Electric GV4PE115S TeSys GV4 MPCB, 3P 115 A, 100 kA Icu at 400 V, electronic trip unit.
GV4PE115N Schneider Electric · Schneider Electric GV4PE115N TeSys GV4 MPCB, 3P 115 A, 50 kA Icu at 400 V, electronic trip unit.
GV4PE07N Schneider Electric · Schneider Electric GV4PE07N TeSys GV4 MPCB, 3P 7 A, 50 kA Icu at 400 V, electronic trip unit.
GV4PE02N Schneider Electric · Schneider Electric GV4PE02N TeSys GV4 MPCB, 3P 2 A, 50 kA Icu at 400 V, electronic trip unit.
GV4P80S Schneider Electric · Schneider Electric GV4P80S TeSys GV4 MPCB, 3P 80 A, 100 kA Icu at 400 V, thermal-magnetic trip unit.
GV4P80N Schneider Electric · TeSys GV4 (GV4P) motor circuit breaker, 3P, Ir 40-80 A thermal-magnetic, 690 V AC, Icu 50 kA.
GV4P80B Schneider Electric · TeSys GV4 (GV4P) motor circuit breaker, 3P, Ir 40-80 A thermal-magnetic, 690 V AC, Icu 25 kA.
GV4P50N Schneider Electric · TeSys GV4 (GV4P) motor circuit breaker, 3P, Ir 20-50 A thermal-magnetic, 690 V AC, Icu 50 kA.
GV4P50B Schneider Electric · TeSys GV4 (GV4P) motor circuit breaker, 3P, Ir 20-50 A thermal-magnetic, 690 V AC, Icu 25 kA.
GV4P25N TeSys GV4Schneider Electric · TeSys GV4 motor circuit breaker, 3P, 25 A, Icu 50 kA at 400 V, 5.5-11 kW
GV4P12N TeSys GV4Schneider Electric · TeSys GV4 motor circuit breaker, 3P, 12.5 A, Icu 50 kA at 400 V, 3-5.5 kW
GV4P115S TeSys GV4Schneider Electric · TeSys GV4 motor circuit breaker, 3P, 115 A, Icu 100 kA at 400 V, 37-55 kW
GV4P115N TeSys GV4Schneider Electric · TeSys GV4 motor circuit breaker, 3P, 115 A, Icu 50 kA at 400 V, 37-55 kW
GV4P115B TeSys GV4Schneider Electric · TeSys GV4 motor circuit breaker, 3P, 115 A, Icu 25 kA at 400 V, 37-55 kW
GV4P07N Schneider Electric · TeSys GV4 (GV4P) motor circuit breaker, 3P, Ir 2.9-7 A thermal-magnetic, 690 V AC, Icu 50 kA.
GV4P03N Schneider Electric · TeSys GV4 (GV4P) motor circuit breaker, 3P, Ir 1.4-3.5 A thermal-magnetic, 690 V AC, Icu 50 kA.
GV4LE80N Schneider Electric · TeSys GV4 (GV4L) motor circuit breaker, 3P, 80 A magnetic, 690 V AC, Icu 50 kA, toggle control.
GV4LE50N Schneider Electric · TeSys GV4 (GV4L) motor circuit breaker, 3P, 50 A magnetic, 690 V AC, Icu 50 kA, toggle control.
GV4LE25N Schneider Electric · TeSys GV4 (GV4L) motor circuit breaker, 3P, 25 A magnetic, 690 V AC, Icu 50 kA, toggle control.
GV4LE12N Schneider Electric · TeSys GV4 (GV4L) motor circuit breaker, 3P, 12.5 A magnetic, 690 V AC, Icu 50 kA, toggle control.
GV4LE07N Schneider Electric · TeSys GV4 (GV4L) motor circuit breaker, 3P, 7 A magnetic, 690 V AC, Icu 50 kA, toggle control.
GV4LE03N Schneider Electric · TeSys GV4 (GV4L) motor circuit breaker, 3P, 3.5 A magnetic, 690 V AC, Icu 50 kA, toggle control.
GV4LE02N Schneider Electric · TeSys GV4 (GV4L) motor circuit breaker, 3P, 2 A magnetic, 690 V AC, Icu 50 kA, toggle control.
GV4L80N Schneider Electric · TeSys GV4 (GV4L) motor circuit breaker, 3P, 80 A magnetic, 690 V AC, Icu 50 kA.
GV4L50N Schneider Electric · TeSys GV4 (GV4L) motor circuit breaker, 3P, 50 A magnetic, 690 V AC, Icu 50 kA.
GV4L12N Schneider Electric · TeSys GV4 (GV4L) motor circuit breaker, 3P, 12.5 A magnetic, 690 V AC, Icu 50 kA.
GV4L115N Schneider Electric · TeSys GV4 (GV4L) motor circuit breaker, 3P, 115 A magnetic, 690 V AC, Icu 50 kA.
GV4L03N Schneider Electric · TeSys GV4 (GV4L) motor circuit breaker, 3P, 3.5 A magnetic, 690 V AC, Icu 50 kA.
GV3P73 GV4LSchneider Electric · GV4L 3-Pole 62-73A TeSys Deca Motor Circuit Breaker
GV3L65 GV3LSchneider Electric · TeSys Deca GV3L manual motor circuit breaker, 65 A magnetic trip, 690 V AC, 50 kA Icu at 400/415 V, rotary handle.
GV3L50 GV3PSchneider Electric · TeSys GV3 / TeSys Deca · GV3P 3P 50A 50kA 690V TeSys Deca Manual Motor Starter Circuit Breaker
GV3L40 GV3LSchneider Electric · TeSys Deca GV3L manual motor circuit breaker, 40 A magnetic trip, 690 V AC, 50 kA Icu at 400/415 V, rotary handle.
GV2RT21 Schneider Electric · TeSys Deca (GV2RT) motor circuit breaker, 3P, 17-23 A thermal-magnetic, 690 V AC, Icu 15 kA.
GV2RT20 Schneider Electric · TeSys Deca (GV2RT) motor circuit breaker, 3P, 13-18 A thermal-magnetic, 690 V AC, Icu 15 kA.
GV2RT16 Schneider Electric · TeSys Deca (GV2RT) motor circuit breaker, 3P, 9-14 A thermal-magnetic, 690 V AC, Icu 15 kA.
GV2RT14 Schneider Electric · TeSys Deca (GV2RT) motor circuit breaker, 3P, 6-10 A thermal-magnetic, 690 V AC, Icu 100 kA.
GV2RT10 Schneider Electric · TeSys Deca (GV2RT) motor circuit breaker, 3P, 4-6.3 A thermal-magnetic, 690 V AC, Icu 100 kA.
GV2RT08 Schneider Electric · TeSys Deca (GV2RT) motor circuit breaker, 3P, 2.5-4 A thermal-magnetic, 690 V AC, Icu 100 kA.
GV2RT07 Schneider Electric · TeSys Deca (GV2RT) motor circuit breaker, 3P, 1.6-2.5 A thermal-magnetic, 690 V AC, Icu 100 kA.
GV2RT06 Schneider Electric · TeSys Deca (GV2RT) motor circuit breaker, 3P, 1-1.6 A thermal-magnetic, 690 V AC, Icu 100 kA.
GV2RT05 Schneider Electric · TeSys Deca (GV2RT) motor circuit breaker, 3P, 0.63-1 A thermal-magnetic, 690 V AC, Icu 100 kA.
GV2RT04 Schneider Electric · TeSys Deca (GV2RT) motor circuit breaker, 3P, 0.4-0.63 A thermal-magnetic, 690 V AC, Icu 100 kA.
GV2RT03 Schneider Electric · TeSys Deca (GV2RT) motor circuit breaker, 3P, 0.25-0.4 A thermal-magnetic, 690 V AC, Icu 100 kA.
GV2P32 GV2RTSchneider Electric · GV2RT 3-Pole 24-32A TeSys Deca Manual Starter and Protector
GV2P22 GV2RTSchneider Electric · GV2RT 3P 20-25A Manual Starter and Protector TeSys Deca
GV2P21 GV2RTSchneider Electric · GV2RT 3-Pole 17-23A TeSys Deca Manual Starter and Protector
GV2P20 GV2RTSchneider Electric · GV2RT 3-Pole 13-18A Manual Starter and Protector TeSys Deca
Can't find the part you need?
Send the part numbers or the specs you need. We reply with price, stock and dispatch time per line.
Motor Protection Circuit Breakers (MPCB) buying guide
What's in this range
- Siemens SIRIUS 3RV2 and 3RV1 breakers, plus 3RN2 versions for motor protection with thermistor evaluation.
- Schneider Electric TeSys Deca GV2 and GV3 manual starters, TeSys GV4 thermal-magnetic breakers and Easy TeSys Power.
- ABB MS116, MS132 and MS165 manual motor starters and MO132 magnetic-only breakers.
- Accessories such as auxiliary contacts, busbar adapters and trip indicators for the 3RV1935 and GV2 families.
How to choose
- Setting range. The motor full-load current should sit inside the adjustable thermal band.
- Breaking capacity at the supply voltage, in kA, against the prospective short-circuit current.
- Thermal-magnetic or magnetic-only. Magnetic-only breakers need a separate overload relay.
- Coordination with the contactor, type 1 or type 2 under IEC 60947-4-1.
- Frame size and mounting: DIN rail or busbar system.
Motor Protection Circuit Breakers (MPCB) questions
What is the difference between an MPCB and an MCCB?
An MPCB is built around motor starting currents, with an adjustable thermal band and a magnetic trip set for inrush. An MCCB is a general feeder breaker with a wider rating scale.
Does an MPCB replace the overload relay?
Yes, when it has a thermal release. Magnetic-only types such as the ABB MO132 do not, so they need an overload relay downstream.
Do you export MPCBs outside Turkey?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.