Categories
No result found for your search.
Need help? Contact us
+90 542 203 61013
info@stoklink.com
Your cart is empty
- Home
- All Collections
- I/O Modules & Remote I/O
Filter
I/O Modules & Remote I/O
Schneider Electric NTSAMO0400K Modicon Edge I/O NTS Analog Output Module with Base Remote I/O Module
Schneider Electric NTSAMO0400HK Modicon Edge I/O NTS Analog Output Module Hardened with Base Remote I/O Module
Schneider Electric NTSAMO0210K Modicon Edge I/O NTS Analog Output Module with Base Remote I/O Module
Schneider Electric NTSAMO0210HK Modicon Edge I/O NTS Analog Output Module Hardened with Base Remote I/O Module
Schneider Electric NTSAMM0600K Modicon Edge I/O NTS Analog Input/Output Module with Base Remote I/O Module
Schneider Electric NTSAMI0800K Modicon Edge I/O NTS Analog Input Module with Base Remote I/O Module
Schneider Electric NTSAMI0420K Modicon Edge I/O NTS Analog Input Module with Base Remote I/O Module
Schneider Electric NTSAMI0400K Modicon Edge I/O NTS Analog Input Module with Base Remote I/O Module
Schneider Electric NTSAMI0210K Edge I/O NTS 2-Channel Isolated Current Voltage Input Remote I/O Module
Schneider Electric NTSAMI0210HK Edge I/O NTS 2-Ch Isolated Hardened Current Voltage Input Remote I/O Module
Schneider Electric NTSACI0802XK Edge I/O NTS 8-Channel Current Analog Input Remote I/O Module
Schneider Electric NTSACI0802XHK Edge I/O NTS 8-Channel Hardened Current Analog Input Remote I/O Module
Schneider Electric SR3XT61FU Zelio Logic SR3 6 I/O Extension Module 100-240 V AC PLC I/O Module
Schneider Electric SR3XT61BD Zelio Logic SR3 6 I/O Extension Module 24 V DC PLC I/O Module
Schneider Electric SR3XT43BD Zelio Logic SR3 4 I/O Analogue Extension Module 24 V DC PLC I/O Module
Schneider Electric SR3XT141FU Zelio Logic SR3 14 I/O Extension Module 100-240 V AC PLC I/O Module
Schneider Electric SR3XT141BD Zelio Logic SR3 14 I/O Extension Module 24 V DC PLC I/O Module
Schneider Electric SR3XT101FU Zelio Logic SR3 10 I/O Extension Module 100-240 V AC PLC I/O Module
Schneider Electric SR3XT101BD Zelio Logic SR3 10 I/O Extension Module 24 V DC PLC I/O Module
Schneider Electric BMXPRA0100 Modicon X80 Remote I/O Adaptor EtherNet/IP Remote I/O Module
PLC I/O modules and remote I/O from Siemens, Schneider Electric and ABB. The range has over 600 products, including digital input and output modules, analog modules, fail-safe I/O and bus couplers for SIMATIC ET 200SP, ET 200AL, Modicon TM3 and X80, and ABB S500. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Digital input and output modules at 24 V DC and 120/230 V AC, including relay outputs.
- Analog input and output modules for current, voltage and temperature signals.
- Fail-safe I/O such as SIMATIC ET 200SP F-DI and ABB AI581-S safety modules.
- Interface modules and bus couplers, for example ET 200SP IM 155-6 and Modicon TM3 EtherNet/IP.
How to choose
- Platform match: I/O modules are specific to their rack or bus, so match the series.
- Signal type: sourcing or sinking, 24 V DC or AC, relay or transistor output, current rating per channel.
- Analog resolution and range: 4-20 mA, 0-10 V or RTD, and 12-bit versus 16-bit.
- Protection class: IP20 for cabinets, IP67 for machine-mounted field I/O.
FAQ
Can I use S7-1200 signal modules with an ET 200SP?
No. ET 200SP uses its own I/O modules and base units. S7-1200 modules only work with S7-1200 CPUs.
What is the difference between a relay and a transistor output module?
Relay outputs switch AC or DC loads with isolation but wear mechanically. Transistor outputs switch DC loads quickly and have no contact wear.
Can I order a full rack of modules?
Stoklink ships worldwide from Turkey under EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.