- Home
- All Collections
- Power Contactors (AC-3)
Power Contactors (AC-3)
Siemens 5TT5800-0 5TT5 20A 230V Contactor
Siemens 3TY7693-0CM7 3TY7 240V Contactor
Siemens 3TY7683-0CM7 3TY7 240V Contactor
Siemens 3TY7403-0AP0 3TY7 230V Contactor
Siemens 3TY7403-0AF0 3TY7 110V Contactor
Siemens 3TY7403-0AB0 3TY7 24V Contactor
Siemens 3TF6944-0CM7 3TF6 630A 3P 400V Contactor
Siemens 3TF6844-0CM7 3TF6 630A 3P 400V Contactor
Siemens 3RT2947-6A 3RT2 Contactor
Siemens 3RT2946-6A 3RT2 Contactor
Siemens 3RT2945-6A 3RT2 Contactor
Siemens 3RT2944-5AP01 3RT2 230V Contactor
Siemens 3RT2938-6A 3RT2 Contactor
Siemens 3RT2937-6A 3RT2 Contactor
Siemens 3RT2936-6A 3RT2 Contactor
Siemens 3RT2936-1CD00 3RT2 240V Contactor
Siemens 3RT2936-1CB00 3RT2 48V Contactor
Siemens 3RT2936-1BD00 3RT2 240V Contactor
Siemens 3RT2936-1BB00 3RT2 48V Contactor
Siemens 3RT2935-6A 3RT2 Contactor
Power contactors (AC-3) from ABB, Schneider Electric and Siemens start and stop three-phase motors and switch heavy loads. The range covers over 650 products from 6 A to 2650 A, with motor ratings from 2.2 kW to 450 kW, mostly in 3 and 4 pole versions. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- ABB AF Contactors – 3 and 4 pole AF series with wide-range AC/DC coils.
- Schneider TeSys Deca Contactors – the largest series here, from 9 A to 200 A.
- Schneider TeSys Giga Contactors – high-current frames from 115 A to 800 A.
- Schneider TeSys K Contactors – compact contactors for 6 A to 16 A.
- Schneider Easy TeSys Contactors – general-purpose contactors from 6 A to 630 A.
- Siemens SIRIUS 3RT2 Contactors and Siemens SIRIUS 3RT1 Contactors – SIRIUS frames from small to very large.
How to choose
- Motor power and current in AC-3 at your supply voltage. Do not size from the AC-1 value.
- Pole count: 3P for motors, 4P where the neutral is switched.
- Coil voltage and type, AC or DC, against the control supply.
- Short-circuit protection and overload relay matched to the contactor, following the manufacturer's coordination tables.
- Auxiliary contact needs and whether add-on blocks fit the frame.
FAQ
What does AC-3 mean on a contactor?
AC-3 is the IEC 60947-4-1 category for starting and stopping squirrel-cage motors. Ratings in AC-3 are usually lower than AC-1 for the same frame.
Can I replace a contactor with another brand?
Check rated current in AC-3, pole count, coil voltage and mounting dimensions. Auxiliary contacts and coordination with the overload relay must also match.
Do you ship contactors outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.