Schneider Electric LC1D18ABD TeSys Deca Contactor 3P 3NO AC-3 18 A ≤440V 24 V DC Coil Snap-In Contactor
Schneider Electric LC1D12AM7 TeSys Deca Contactor 3P 3NO AC-3 12 A ≤440V 220 V AC Coil Snap-In Contactor
Schneider Electric LC1D12ABD TeSys Deca Contactor 3P 3NO AC-3 12 A ≤440V 24 V DC Coil Snap-In Contactor
Schneider Electric LC1D09AM7 TeSys Deca Contactor 3P 3NO AC-3 9 A ≤440V 220 V AC Coil Snap-In Contactor
Schneider Electric LC1D09ABD TeSys Deca Contactor 3P 3NO AC-3 9 A ≤440V 24 V DC Coil Snap-In Contactor
Siemens 8US1261-5FP08 8US1 56A Contactor
Siemens 5TT5853-0 5TT5 63A 230V Contactor
Siemens 5TT5852-0 5TT5 63A 230V Contactor
Siemens 5TT5851-0 5TT5 63A 230V Contactor
Siemens 5TT5850-0 5TT5 63A 230V Contactor
Siemens 5TT5843-0 5TT5 40A 230V Contactor
Siemens 5TT5842-0 5TT5 40A 230V Contactor
Siemens 5TT5841-0 5TT5 40A 230V Contactor
Siemens 5TT5840-0 5TT5 40A 230V Contactor
Siemens 5TT5833-0 5TT5 25A 230V Contactor
Siemens 5TT5832-0 5TT5 25A 230V Contactor
Siemens 5TT5831-0 5TT5 25A 230V Contactor
Siemens 5TT5830-0 5TT5 25A 230V Contactor
Siemens 5TT5802-0 5TT5 20A 230V Contactor
Siemens 5TT5801-0 5TT5 20A 230V Contactor
Power contactors (AC-3) from ABB, Schneider Electric and Siemens start and stop three-phase motors and switch heavy loads. The range covers over 650 products from 6 A to 2650 A, with motor ratings from 2.2 kW to 450 kW, mostly in 3 and 4 pole versions. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- ABB AF Contactors – 3 and 4 pole AF series with wide-range AC/DC coils.
- Schneider TeSys Deca Contactors – the largest series here, from 9 A to 200 A.
- Schneider TeSys Giga Contactors – high-current frames from 115 A to 800 A.
- Schneider TeSys K Contactors – compact contactors for 6 A to 16 A.
- Schneider Easy TeSys Contactors – general-purpose contactors from 6 A to 630 A.
- Siemens SIRIUS 3RT2 Contactors and Siemens SIRIUS 3RT1 Contactors – SIRIUS frames from small to very large.
How to choose
- Motor power and current in AC-3 at your supply voltage. Do not size from the AC-1 value.
- Pole count: 3P for motors, 4P where the neutral is switched.
- Coil voltage and type, AC or DC, against the control supply.
- Short-circuit protection and overload relay matched to the contactor, following the manufacturer's coordination tables.
- Auxiliary contact needs and whether add-on blocks fit the frame.
FAQ
What does AC-3 mean on a contactor?
AC-3 is the IEC 60947-4-1 category for starting and stopping squirrel-cage motors. Ratings in AC-3 are usually lower than AC-1 for the same frame.
Can I replace a contactor with another brand?
Check rated current in AC-3, pole count, coil voltage and mounting dimensions. Auxiliary contacts and coordination with the overload relay must also match.
Do you ship contactors outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.