Schneider Electric LUCA32ES TeSys U Standard Control Unit 8-32 A 48 V AC Motor Starter Module

Reference No: LUCA32ES
Rated Current (A): 32
Rated Voltage (VAC): 48 V AC
0 pcs in stock
$124.38

Schneider Electric LUCA32BL TeSys U Standard Control Unit 8-32 A 24 V DC Motor Starter Module

Reference No: LUCA32BL
Rated Current (A): 32
0 pcs in stock
$124.38

Schneider Electric LUCA32B TeSys U Standard Control Unit 8-32 A 24 V AC Motor Starter Module

Reference No: LUCA32B
Rated Current (A): 32
Rated Voltage (VAC): 24 V AC
0 pcs in stock
$124.38

Schneider Electric LUCA1XFU TeSys U Standard Control Unit 0.35-1.4 A 110-240 V AC Motor Starter Module

Reference No: LUCA1XFU
Rated Current (A): 1.4
Rated Voltage (VAC): 110/240 V AC
0 pcs in stock
$81.16

Schneider Electric LUCA1XES TeSys U Standard Control Unit 0.35-1.4 A 48 V AC Motor Starter Module

Reference No: LUCA1XES
Rated Current (A): 1.4
Rated Voltage (VAC): 48 V AC
0 pcs in stock
$81.16

Schneider Electric LUCA1XBL TeSys U Standard Control Unit 0.35-1.4 A 24 V DC Motor Starter Module

Reference No: LUCA1XBL
Rated Current (A): 1.4
0 pcs in stock
$81.16

Schneider Electric LUCA1XB TeSys U Standard Control Unit 0.35-1.4 A 24 V AC Motor Starter Module

Reference No: LUCA1XB
Rated Current (A): 1.4
Rated Voltage (VAC): 24 V AC
0 pcs in stock
$81.16

Schneider Electric LUCA18FU TeSys U Standard Control Unit 4.5-18 A 110-240 V AC Motor Starter Module

Reference No: LUCA18FU
Rated Current (A): 18
Rated Voltage (VAC): 110/240 V AC
0 pcs in stock
$91.08

Schneider Electric LUCA18BL TeSys Ultra 4.5–18A 3P Control Unit

Reference No: LUCA18BL
Rated Current (A): 18
Number of Poles: 3P
16 pcs in stock
$97.49

Schneider Electric LUCA18B TeSys U Standard Control Unit 4.5-18 A 24 V AC Motor Starter Module

Reference No: LUCA18B
Rated Current (A): 18
Rated Voltage (VAC): 24 V AC
0 pcs in stock
$91.08

Schneider Electric LUCA12FU TeSys Ultra Control Unit 3-12A Motor Control

Reference No: LUCA12FU
Rated Current (A): 12
4 pcs in stock
$94.37

Schneider Electric LUCA12BL TeSys Ultra 3-12A Control Unit for Motor Protection

Reference No: LUCA12BL
Rated Current (A): 12
32 pcs in stock
$94.37

Schneider Electric LUCA12B TeSys U Standard Control Unit 3-12 A 24 V AC Motor Starter Module

Reference No: LUCA12B
Rated Current (A): 12
Rated Voltage (VAC): 24 V AC
0 pcs in stock
$88.17

Schneider Electric LUCA05FU TeSys Ultra Control Unit 1.25-5A 110-220V DC/AC

Reference No: LUCA05FU
Rated Current (A): 5
Rated Voltage (VAC): 110/220 V AC/DC
16 pcs in stock
$87.64

Schneider Electric LUCA05BL TeSys U Standard Control Unit 1.25-5 A 24 V DC Motor Starter Module

Reference No: LUCA05BL
Rated Current (A): 5
0 pcs in stock
$81.91

Schneider Electric LUCA05B TeSys U Standard Control Unit 1.25-5 A 24 V AC Motor Starter Module

Reference No: LUCA05B
Rated Current (A): 5
Rated Voltage (VAC): 24 V AC
0 pcs in stock
$81.91

Schneider Electric LUB38 TeSys U Starter-Controller Power Base 38 A 3P Non-Reversing Motor Starter Module

Reference No: LUB38
Rated Current (A): 38
0 pcs in stock
$154.93

Schneider Electric LUB32 TeSys U Starter-Controller Power Base 32 A 3P Non-Reversing Motor Starter Module

Reference No: LUB32
Rated Current (A): 32
0 pcs in stock
$144.03

Schneider Electric LUB12 TeSys U Starter-Controller Power Base 12 A 3P Non-Reversing Motor Starter Module

Reference No: LUB12
Rated Current (A): 12
Number of Poles: 3P
0 pcs in stock
$125.83

Schneider Electric LU6MB0FU TeSys U Reverser Block for Side Mounting 38 A 110-240 V AC Motor Starter Module

Reference No: LU6MB0FU
Rated Current (A): 38
Rated Voltage (VAC): 110/240 V AC
Number of Poles: 3P
0 pcs in stock
$232.76

Motor control and protection equipment from ABB, Siemens and Schneider Electric covers everything between the supply and the motor shaft. The range spans contactors, overload relays, motor protection circuit breakers, starters, soft starters, variable frequency drives, servo systems and industrial motors, with rated currents from 0.1 A to 2,650 A and power up to 800 kW. Stoklink ships worldwide from Turkey and quotes project volumes on request.

What's in this range

How to choose

  • Motor power and rated current at the supply voltage. Size the starter or drive for the nameplate current, not just the kW value.
  • Starting method: direct on line, soft start or variable speed. This decides whether you need a contactor, a soft starter or a VFD.
  • Duty class, for example AC-3 for squirrel-cage motors under IEC 60947-4-1.
  • Protection split: overload relay plus fuses or MCB, or a single MPCB.
  • Control interface: coil voltage, fieldbus such as PROFINET, and mounting.

FAQ

What is the difference between a soft starter and a VFD?

A soft starter limits inrush current during start and stop at fixed supply frequency. A VFD changes the output frequency, so it also controls speed while running.

Do I need a contactor and an overload relay, or an MPCB?

An MPCB combines short-circuit and overload protection and works with a contactor. The separate route uses a fuse or MCB, a contactor and an overload relay. Choose by space, coordination type and rating.

Can you ship motor control products outside Turkey?

Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.