Part number
LUCA32ES
Model no
LUCA
$124.38 On request Dispatch — · From TürkiyeGet a Quote
TeSys Ultra

Schneider Electric LUCA32ES TeSys U Standard Control Unit 8-32 A 48 V AC Motor Starter Module

TeSys U standard control unit, 8-32 A adjustable, Class 10, 48-72 V AC/DC coil

Rated current
32 A
Rated operational voltage
48 V AC
EAN
3389110363999
Description

About the LUCA

The Schneider Electric LUCA32ES is a TeSys U standard control unit providing adjustable thermal-magnetic motor protection from 8 to 32 A. Plugged into a LUB32 or LUB38 power base, it forms a complete starter-controller with Class 10 overload tripping, phase-failure sensing, and earth-fault detection for 3-phase motors up to 15 kW at 400 V, controlled from a 48 V AC / 48-72 V DC supply.

Certifications & Standards

  • CE
  • UL
  • CSA
  • CCC
  • EAC
  • IEC 60947-6-2
  • UL 60947-4-1
  • CSA C22.2 No 60947-4-1

Selection Notes

The LUCA32ES extends the 8-32 A, 15 kW band to a 48 V control bus, the middle option between the 24 V LUCA32B/BL and the 110-240 V LUCA32FU equivalent. Protection behavior, Class 10 tripping and the 15 kW rating at 400 V, is identical across all three voltage variants, so the choice comes down purely to what control voltage the panel already distributes. Pick the 24 V LUCA32BL instead if the reversing base in use is the DC-coil LU2B32BL.

Specification

Full specification

63 values · Last verified 30 Oct 2026

Main 19

Range TeSys
Range of Product TeSys Ultra
Product name TeSys Ultra
Device short name LUCA
Product or Component Type Standard control unit
Device Application Motor control, Motor protection
Product Specific Application Basic protection requirements for motor starters: overload and short-circuit
main function available Earth fault protection, Protection against phase failure and phase imbalance, Manual reset, Protection against overload and short-circuit
Product compatibility Power base LUB32, Power base LUB38, Power base LUB320, Power base LUB380, Reversing contactor breaker LU2B32ES
[Ue] rated operational voltage 690 V AC
Network frequency 40...60 Hz
Load type 3-phase motor self-cooled
Utilisation category AC-41, AC-43, AC-44
Motor power kW 15 kW 400...440 V AC 50/60 Hz, 15 kW 500 V AC 50/60 Hz, 18.5 kW 690 V AC 50/60 Hz
rated motor current adjustment range 8…32 A
Thermal overload class Class 10 40…60 Hz -13…158 °F (-25…70 °C) IEC 60947-6-2, Class 10 40…60 Hz -13…158 °F (-25…70 °C) UL 508
Tripping threshold 14.2 x Ir +/- 20 %
Phase failure sensitivity Yes
[Uc] control circuit voltage 48 V AC, 48...72 V DC

Complementary 15

Control circuit voltage limits 38.5...72 V AC 48 V in operation, 38.5...93 V DC 48...72 V in operation, 29 V AC 48 V drop-out, 29 V DC 48...72 V drop-out
Typical current consumption 280 mA 48 V AC I maximum while closing with LUB32, 280 mA 48 V AC I maximum while closing with LUB38, 280 mA 48...72 V DC I maximum while closing with LUB32, 280 mA 48...72 V DC I maximum while closing with LUB38, 45 mA 48 V AC I rms sealed with LUB32, 45 mA 48 V AC I rms sealed with LUB38, 45 mA 48...72 V DC I rms sealed with LUB32, 45 mA 48...72 V DC I rms sealed with LUB38
Heat dissipation 3 W control circuit with LUB32, 3 W control circuit with LUB38
Operating time 35 ms opening with LUB32 control circuit, 35 ms opening with LUB38 control circuit, 60 ms closing with LUB32 control circuit, 60 ms closing with LUB38 control circuit
Standards EN 60947-6-2, IEC 60947-6-2, UL 60947-4-1, with phase barrier, CSA C22.2 No 60947-4-1, with phase barrier
Product Certifications CE, UL, CSA, CCC, EAC, ASEFA, ATEX, Marine
[Ui] rated insulation voltage 690 V IEC 60947-6-2, 600 V UL 60947-4-1, 600 V CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage 6 kV IEC 60947-6-2
Safe separation of circuit 400 V SELV between the control and auxiliary circuits IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Fixing mode Plug-in (front face)
Width 1.8 in (45 mm)
Height 2.6 in (66 mm)
Depth 2.4 in (60 mm)
Net Weight 0.298 lb(US) (0.135 kg)
Compatibility code LUCA

Environment 15

IP degree of protection IP20 front panel and wired terminals IEC 60947-1, IP20 other faces IEC 60947-1, IP40 front panel outside connection zone IEC 60947-1
Protective treatment TH IEC 60068
Ambient air temperature for operation -13…158 °F (-25…70 °C)
Ambient Air Temperature for Storage -40…185 °F (-40…85 °C)
Operating altitude 6561.68 ft (2000 m)
Fire resistance 1760 °F (960 °C) parts supporting live components IEC 60695-2-12, 1202 °F (650 °C) IEC 60695-2-12
Shock resistance 10 gn power poles open IEC 60068-2-27, 15 gn power poles closed IEC 60068-2-27
Vibration resistance 2 gn 5…300 Hz power poles open IEC 60068-2-6, 4 gn 5…300 Hz power poles closed IEC 60068-2-6
Resistance to electrostatic discharge 8 kV 3 in open air IEC 61000-4-2, 8 kV 4 on contact IEC 61000-4-2
Non-dissipating shock wave 1 kV serial mode IEC 60947-6-2, 2 kV common mode IEC 60947-6-2
Resistance to radiated fields 9.1 V/m (10 V/m) 3 IEC 61000-4-3
Resistance to fast transients 2 kV 3 serial link IEC 61000-4-4, 4 kV 4 all circuits except for serial link IEC 61000-4-4
Immunity to radioelectric fields 10 V IEC 61000-4-6
Immunity to microbreaks 3 ms
Immunity to voltage dips 70 % / 500 ms IEC 61000-4-11
Show all 63 specifications ↓ Show less ↑14 more values in Identification, Contractual warranty, Logistics.

Identification 8

Part number LUCA32ES
Type designation LUCA
Brand Schneider Electric
Condition New, factory sealed
Source Schneider Electric and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 3389110363999

Contractual warranty 1

Warranty (in months) 18

Logistics 5

Country of origin FR
Shipping weight 0.135 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 30 Oct 2026

Documents

Documents for LUCA32ES

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • UL
  • CSA
  • CE
  • CCC
  • EAC
  • Marine
  • EN 60947-6-2
  • IEC 60947-6-2
  • UL 60947-4-1
  • with phase barrier
Quick answers

Questions about the LUCA

What is the rated current of LUCA?

The rated current of LUCA is 32 A.

Which supply voltage is LUCA rated for?

The rated operational voltage of LUCA is 48 V AC.

What is the HS code of LUCA for customs?

The tariff (HS) code on file for LUCA is 853650.

What is the EAN of LUCA?

The EAN (GTIN) of LUCA is 3389110363999.

Where does LUCA ship from, and how fast?

LUCA ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for motor starters

All guides for motor starters
Reviews

Customer reviews

Series

Schneider Electric TeSys Ultra

Brand
Schneider Electric
Series
TeSys Ultra
$124.38 On request
Get a Quote
Quote

Get a Quote

LUCA

Genuine parts

Genuine, factory-sealed parts

Schneider Electric · LUCA32ES

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Schneider Electric and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart