- Home
- All Collections
- Motor Control & Protection
Motor Control & Protection
Motor Control & Protection Categories
Motor Control & Protection
Siemens 3RT2016-2BB41 3RT2 9A 3P 400V Contactor
Siemens 1FL2205-4AF11-1MB0 SIMOTICS S-1FL2 Servo Motor 1.45kW 3000rpm 4.6Nm with Brake
Siemens 6SL3210-5BE22-2UV1 SINAMICS V20 2.2kW 400V 3AC Variable Frequency Drive
Siemens 3RU2126-4AB0 3RU2 11...16A 3P 690V Thermal Overload Relay
Siemens 3RU2116-0EB1 3RU2 0.28...0.40A 3P 690V Thermal Overload Relay
3RW5055-6AB14, Soft Starter, 75 kW, 143 A, 200 to 480V AC
Schneider Electric GV2ME06 GV2ME 3-Pole 1-1.6A Manual Starter and Protector TeSys Deca
Schneider Electric LC1D50ABD TeSys Deca 3-Pole 50A 480V AC 40HP 24V DC Coil Power Contactor
Schneider Electric LC1D38BD TeSys Deca 3-Pole 38A 20HP 480V AC 24VDC Coil Power Contactor
Schneider Electric LC1D25BD TeSys Deca 3-Pole 25A 15HP 480V AC 24VDC Coil Power Contactor
Schneider Electric LC1E0910M5 Easy TeSys 3-Pole 9A 440V AC Contactor
Schneider Electric ATV320U40N4C Altivar 320 4kW 3-Phase 380-500V 9.5A Compact Variable Speed Drive
ABB 1SAM451000R1015 MS165-42 Manual Motor Starter 30-42A 45kW 3P Motor Protection Circuit-Breaker
ABB 1SAM201901R1001 HKF1-11 1NO+1NC Front Mount Auxiliary Contact Block
ABB 1SAM350000R1007 MS132-2.5 1.6-2.5A 3P 100kA Motor Protection Circuit-Breaker
ABB 1SAM350000R1006 MS132-1.6 1.0-1.6A 3P 100kA 400VAC Motor Protection Circuit Breaker
ABB 1SBL181024R8010 UA16-30-10RA 220-230V50Hz/230-240V60Hz 3-Pole Contactor
ABB 1SBL347201R1300 AF40-40-00-13 4-Pole 70A 690V AC-1 18.5kW 100-250V Coil Power Contactor AC Switching
ABB 1SBL237201R1300 AF26-40-00-13 4-Pole 45A 690V 11kW Coil 100-250V AC/DC Power Contactor AC Switching
ABB 1SAZ721201R1049 TF42-20 16-20A 3P Thermal Overload Relay
Motor control and protection equipment from ABB, Siemens and Schneider Electric covers everything between the supply and the motor shaft. The range spans contactors, overload relays, motor protection circuit breakers, starters, soft starters, variable frequency drives, servo systems and industrial motors, with rated currents from 0.1 A to 2,650 A and power up to 800 kW. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Contactors – switching devices for motor and load circuits, mostly 3-pole
- Thermal Overload Relays – bimetal and electronic relays for motor overload protection
- Motor Protection Circuit Breakers (MPCB) – short-circuit and overload protection in one device
- Motor Starters & Motor Management – starter combinations and motor controllers such as TeSys U and SIRIUS 3RK
- Soft Starters – controlled ramp-up for 3-phase motors
- Variable Frequency Drives (VFD) – speed control with ABB ACS, Schneider Altivar and Siemens SINAMICS
- Servo Drives & Motion Control – servo motors, drives, controllers and cables
- Industrial Motors – SIMOTICS asynchronous motors
How to choose
- Motor power and rated current at the supply voltage. Size the starter or drive for the nameplate current, not just the kW value.
- Starting method: direct on line, soft start or variable speed. This decides whether you need a contactor, a soft starter or a VFD.
- Duty class, for example AC-3 for squirrel-cage motors under IEC 60947-4-1.
- Protection split: overload relay plus fuses or MCB, or a single MPCB.
- Control interface: coil voltage, fieldbus such as PROFINET, and mounting.
FAQ
What is the difference between a soft starter and a VFD?
A soft starter limits inrush current during start and stop at fixed supply frequency. A VFD changes the output frequency, so it also controls speed while running.
Do I need a contactor and an overload relay, or an MPCB?
An MPCB combines short-circuit and overload protection and works with a contactor. The separate route uses a fuse or MCB, a contactor and an overload relay. Choose by space, coordination type and rating.
Can you ship motor control products outside Turkey?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.