- Home
- All Collections
- Molded Case Circuit Breakers (MCCB)
Molded Case Circuit Breakers (MCCB)
ABB 1SDA104709R1 Kit P MP XT5 630A 3p Plug-In Conversion Circuit Breaker Accessory
ABB 1SDA104707R1 Kit P MP XT5 400A 3p Plug-In Conversion Circuit Breaker Accessory
ABB 1SDA104676R1 XT5 P FP 630A 3p EF EF IEC/UL Plug-In Circuit Breaker Accessory
ABB 1SDA104668R1 XT5 P FP 400A 3p EF EF IEC Plug-In Circuit Breaker Accessory
ABB 1SDA104791R1 AUX-C 1S51 250V AC/dC XT5-XT6 W 1 CO Contact Circuit Breaker Accessory
ABB 1SDA066430R1 AUX-SA-C 1S51 250Vac/dc XT2-XT4 W 1NO+1NC 250V AC/DC Withdrawable Auxiliary Contact Signaling Contact for Circuit Breaker
ABB 1SDA104798R1 AUX-C 3Q+1SY 250V AC XT5-XT6 W 4 CO Contacts Circuit Breaker Accessory
ABB 1SDA104796R1 AUX-C 2Q+1SY 250V AC/CC XT5-XT6 W 3 CO Contacts Circuit Breaker Accessory
ABB 1SDA104931R1 YO-C XT5 W 380…440 Vac Shunt Trip Release Circuit Breaker Accessory
ABB 1SDA066333R1 SOR-C XT2-XT4 W 380-440 Vac Circuit Breaker Accessory
ABB 1SDA104935R1 YO-C XT5-XT6 F/P 380…440 Vac Shunt Trip Release Circuit Breaker Accessory
ABB 1SDA104951R1 YU-C XT5 W 220..240 Vac - 220..250 Vdc Undervoltage Release Circuit Breaker Accessory
ABB 1SDA104959R1 YU-C XT5-XT6 F/P 380...440 Vac Undervoltage Release Circuit Breaker Accessory
ABB 1SDA104952R1 YU-C XT5 W 380...440 Vac Undervoltage Release Circuit Breaker Accessory
ABB 1SDA066407R1 UVR-C XT2-XT4 W 380-440 Vac Circuit Breaker Accessory
ABB 1SDA066472R1 MOE-E XT2-XT4 220..250V ac/dc X REM.CONT Circuit Breaker Accessory
ABB 1SDA100442R1 XT5S 400 Ekip M Dip LIU In=400A 3p F F 50kA Molded Case Circuit Breaker (MCCB)
ABB 1SDA101171R1 XT7H 1000 Ekip Dip LS/I In=1000A 4p F F 70kA Molded Case Circuit Breaker (MCCB)
ABB 1SDA100776R1 XT6H 800 Ekip Dip LS/I In=800 4p F F 70kA Molded Case Circuit Breaker (MCCB)
ABB 1SDA101710R1 XT7H M 800 Ekip Dip LS/I In=800A 4p F F 800A 4-Pole Fixed Power Circuit Breaker
Molded case circuit breakers (MCCB) from ABB, Schneider Electric and Siemens protect feeders, motors and distribution boards from about 10 A up to 1600 A. The range covers 3-pole and 4-pole breakers with fixed and adjustable trip units, with more than 1,800 products including accessories. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- ABB Tmax XT MCCBs – XT1 to XT7 frames with thermal-magnetic and Ekip electronic trip units.
- ABB Formula A MCCBs – A1 to A3 frames for general distribution.
- Schneider ComPacT NSX MCCBs – frames from 100 A to 630 A.
- Schneider ComPacT NS MCCBs – breakers from 630 A to 1600 A.
- Schneider GoPact MCCBs – compact breakers up to 800 A.
- Schneider EasyPact CVS MCCBs – CVS100 to CVS630 frames.
- Siemens SENTRON 3VA MCCBs – 3VA1 and 3VA2 breakers up to 1250 A.
- Siemens SENTRON 3VM MCCBs – 3VM1 breakers up to 630 A.
- MCCB Accessories, Releases & Trip Units – releases and trip units.
How to choose
- Frame size and rated current, with the trip unit set to the load current.
- Rated breaking capacity (Icu and Ics) at the system voltage, above the prospective short-circuit current.
- Trip unit: thermal-magnetic for simple feeders, electronic (LSI or LSIG) where selectivity is needed.
- Poles: 3P or 4P according to the neutral arrangement. Standard: IEC 60947-2.
FAQ
What is the difference between an MCCB and an ACB?
An MCCB is a compact molded-case breaker, typically used from tens of amperes to 1600 A. An ACB is a larger, often draw-out breaker for main incomers from 630 A upward.
What do Icu and Ics mean on an MCCB?
Icu is the ultimate breaking capacity. Ics is the service breaking capacity, the share of Icu after which the breaker stays fit for service.
Do you export MCCBs and their accessories?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.