- Home
- All Collections
- Molded Case Circuit Breakers (MCCB)
Molded Case Circuit Breakers (MCCB)
ABB 1SDA100910R1 XT7H 800 Ekip Touch Meas.LSI In800 3p FF 70kA Molded Case Circuit Breaker (MCCB)
ABB 1SDA100911R1 XT7H 1000 Ekip Touch Meas.LSI 1000 3p FF 70kA Molded Case Circuit Breaker (MCCB)
ABB 1SDA100912R1 XT7H 1250 Ekip Touch Meas.LSI 1250 3p FF 70kA Molded Case Circuit Breaker (MCCB)
ABB 1SDA100913R1 XT7H 1600 Ekip Touch Meas.LSI 1600 3p FF 70kA Molded Case Circuit Breaker (MCCB)
ABB 1SDA100846R1 XT7S 800 Ekip Touch Meas.LSI In800 3p FF 50kA Molded Case Circuit Breaker (MCCB)
ABB 1SDA100848R1 XT7S 1250 Ekip Touch Meas.LSI 1250 3p FF 50kA Molded Case Circuit Breaker (MCCB)
ABB 1SDA054849R1 KIT MP T5 630 W 3p Withdrawable 3-Pole 630A Tmax T5 Motor Operator Kit Accessory
ABB 1SDA063050R1 T7H 1600 PR231/P LS/I In=1600A 4p F F M 4P 1600A Molded Case Circuit Breaker
ABB 1SDA062874R1 T7S 1250 PR231/P LS/I In=1250A 4p F F 1250A 4-Pole Fixed Power Circuit Breaker
ABB 1SDA061981R1 T7S 800 PR231/P LS/I In=800A 3p F F M 800A 3-Pole Fixed Power Circuit Breaker
ABB 1SDA105002R1 PB 100mm 4pcs XT5 3p KIT PA.DI.PH.HI Phase Divider Circuit Breaker Accessory
ABB 1SDA105003R1 PB 100mm 6pcs XT5 4p KIT PA.DI.PH.HI Phase Divider Circuit Breaker Accessory
ABB 1SDA105011R1 PB 100mm 6pcs XT6 4p KIT PA.DI.PH.HI Circuit Breaker Accessory
ABB 1SDA105004R1 PB 200mm 4pcs XT5 3p KIT PA.DI.PH.HI Circuit Breaker Accessory
ABB 1SDA105010R1 PB 100mm 4pcs XT6 3p KIT PA.DI.PH.HI Phase Divider Circuit Breaker Accessory
ABB 1SDA066677R1 PB 200mm 4pcs XT2-XT4 3p KIT PA.DI.PH.HI Circuit Breaker Accessory
ABB 1SDA107474R1 KIT EF XT6 4pcs 1000A 4-Pole Circuit Breaker Accessory
ABB 1SDA104737R1 KIT EF XT6 4pcs 800A 4-Pole Circuit Breaker Accessory
ABB 1SDA104736R1 KIT EF XT6 3pcs 800A 3-Pole Circuit Breaker Accessory
ABB 1SDA107473R1 KIT EF XT6 3pcs 1000A 3-Pole Circuit Breaker Accessory
Molded case circuit breakers (MCCB) from ABB, Schneider Electric and Siemens protect feeders, motors and distribution boards from about 10 A up to 1600 A. The range covers 3-pole and 4-pole breakers with fixed and adjustable trip units, with more than 1,800 products including accessories. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- ABB Tmax XT MCCBs – XT1 to XT7 frames with thermal-magnetic and Ekip electronic trip units.
- ABB Formula A MCCBs – A1 to A3 frames for general distribution.
- Schneider ComPacT NSX MCCBs – frames from 100 A to 630 A.
- Schneider ComPacT NS MCCBs – breakers from 630 A to 1600 A.
- Schneider GoPact MCCBs – compact breakers up to 800 A.
- Schneider EasyPact CVS MCCBs – CVS100 to CVS630 frames.
- Siemens SENTRON 3VA MCCBs – 3VA1 and 3VA2 breakers up to 1250 A.
- Siemens SENTRON 3VM MCCBs – 3VM1 breakers up to 630 A.
- MCCB Accessories, Releases & Trip Units – releases and trip units.
How to choose
- Frame size and rated current, with the trip unit set to the load current.
- Rated breaking capacity (Icu and Ics) at the system voltage, above the prospective short-circuit current.
- Trip unit: thermal-magnetic for simple feeders, electronic (LSI or LSIG) where selectivity is needed.
- Poles: 3P or 4P according to the neutral arrangement. Standard: IEC 60947-2.
FAQ
What is the difference between an MCCB and an ACB?
An MCCB is a compact molded-case breaker, typically used from tens of amperes to 1600 A. An ACB is a larger, often draw-out breaker for main incomers from 630 A upward.
What do Icu and Ics mean on an MCCB?
Icu is the ultimate breaking capacity. Ics is the service breaking capacity, the share of Icu after which the breaker stays fit for service.
Do you export MCCBs and their accessories?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.