- Home
- All Collections
- Molded Case Circuit Breakers (MCCB)
Molded Case Circuit Breakers (MCCB)
ABB 1SDA100777R1 XT6H 1000 Ekip Dip LS/I In=1000 4p F F 70kA Molded Case Circuit Breaker (MCCB)
ABB 1SDA101172R1 XT7H 1250 Ekip Dip LS/I In=1250A 4p F F 70kA Molded Case Circuit Breaker (MCCB)
ABB 1SDA067895R1 XT2H 160 Ekip Dip LS/I In=160A 4pFF 70kA Molded Case Circuit Breaker (MCCB)
ABB 1SDA100529R1 XT5H 630 Ekip Dip LS/I In=630 4p F F 70kA Molded Case Circuit Breaker (MCCB)
ABB 1SDA100528R1 XT5H 400 Ekip Dip LS/I In=400 4p F F 70kA Molded Case Circuit Breaker (MCCB)
ABB 1SDA068535R1 XT4H 250 Ekip Dip LS/I In=250A 4p F F 70kA Molded Case Circuit Breaker (MCCB)
ABB 1SDA067838R1 XT2S 160 Ekip Dip LS/I In=160A 4pFF 50kA Molded Case Circuit Breaker (MCCB)
ABB 1SDA067090R1 XT2N 160 Ekip Dip LS/I In=10A 4p F F 36kA Molded Case Circuit Breaker (MCCB)
ABB 1SDA068329R1 XT4S 250 TMA 200-2000 4p F F InN=100% 50kA Molded Case Circuit Breaker (MCCB)
ABB 1SDA067582R1 XT2S 160 TMA 125-1250 4p F F 50kA Molded Case Circuit Breaker (MCCB)
ABB 1SDA067091R1 XT2N 160 Ekip Dip LS/I In=25A 4p F F 36kA Molded Case Circuit Breaker (MCCB)
ABB 1SDA100521R1 XT5H 400 TMA 400-4000 4p F F InN=100%In 70kA Molded Case Circuit Breaker (MCCB)
ABB 1SDA100775R1 XT6H 800 TMA 800-8000 4p F F InN=100%In 70kA Molded Case Circuit Breaker (MCCB)
ABB 1SDA100525R1 XT5H 630 TMA 630-6300 4p F F InN=100%In 70kA Molded Case Circuit Breaker (MCCB)
ABB 1SDA067459R1 XT1H 160 TMD 80-800 4p F F 80A 4-Pole Fixed Moulded Case Circuit Breaker
ABB 1SDA080854R1 XT1H 160 TMD 40-450 4p F F 70kA Molded Case Circuit Breaker (MCCB)
ABB 1SDA080853R1 XT1H 160 TMD 32-450 4p F F 70kA Molded Case Circuit Breaker (MCCB)
ABB 1SDA100891R1 XT7H 1000 Ekip Dip LS/I In=1000A 3p F F 70kA Molded Case Circuit Breaker (MCCB)
ABB 1SDA066570R1 A3S 400 TMF 320-3200 4p F F InN=100%In 320A 4-Pole Fixed Power Circuit-Breaker
ABB 1SDA066758R1 A1N 125 TMF 20-400 4p F F 20A 4-Pole Fixed Moulded Case Circuit Breaker
Molded case circuit breakers (MCCB) from ABB, Schneider Electric and Siemens protect feeders, motors and distribution boards from about 10 A up to 1600 A. The range covers 3-pole and 4-pole breakers with fixed and adjustable trip units, with more than 1,800 products including accessories. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- ABB Tmax XT MCCBs – XT1 to XT7 frames with thermal-magnetic and Ekip electronic trip units.
- ABB Formula A MCCBs – A1 to A3 frames for general distribution.
- Schneider ComPacT NSX MCCBs – frames from 100 A to 630 A.
- Schneider ComPacT NS MCCBs – breakers from 630 A to 1600 A.
- Schneider GoPact MCCBs – compact breakers up to 800 A.
- Schneider EasyPact CVS MCCBs – CVS100 to CVS630 frames.
- Siemens SENTRON 3VA MCCBs – 3VA1 and 3VA2 breakers up to 1250 A.
- Siemens SENTRON 3VM MCCBs – 3VM1 breakers up to 630 A.
- MCCB Accessories, Releases & Trip Units – releases and trip units.
How to choose
- Frame size and rated current, with the trip unit set to the load current.
- Rated breaking capacity (Icu and Ics) at the system voltage, above the prospective short-circuit current.
- Trip unit: thermal-magnetic for simple feeders, electronic (LSI or LSIG) where selectivity is needed.
- Poles: 3P or 4P according to the neutral arrangement. Standard: IEC 60947-2.
FAQ
What is the difference between an MCCB and an ACB?
An MCCB is a compact molded-case breaker, typically used from tens of amperes to 1600 A. An ACB is a larger, often draw-out breaker for main incomers from 630 A upward.
What do Icu and Ics mean on an MCCB?
Icu is the ultimate breaking capacity. Ics is the service breaking capacity, the share of Icu after which the breaker stays fit for service.
Do you export MCCBs and their accessories?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.