- Home
- All Collections
- Safety Relays
Safety Relays
Schneider Electric | XPSAC5121 Emergency Stop Module (24 V AC/DC)
Schneider Electric XPSUS32AP Preventa XPSU Cat. 4 Enabling Switch Monitoring 48-240V AC/DC Safety Relay
Schneider Electric XPSUS12AP Preventa XPSU Cat. 4 24 V AC/DC Enabling 2 NO Safety Relay
Schneider Electric XPSUEP34AP Preventa XPSU Cat. 4 48-240 V AC/DC Expansion 4 NO Safety Relay
Schneider Electric XPSUEP14AP Preventa XPSU Cat. 4 24 V AC/DC Expansion 4 NO Safety Relay
Schneider Electric XPSUDN33AP Preventa XPSU Cat. 4 48-240 V AC/DC 6-Input Safety Relay
Schneider Electric XPSUDN13AP Preventa XPSU Cat. 4 24 V AC/DC 6-Input Safety Relay
Schneider Electric XPSUAT33A3AP Preventa XPSU Cat. 4 48-240 V AC/DC Delayed Output Safety Relay
Schneider Electric XPSUAT13A3AP Preventa XPSU Cat. 4 24 V AC/DC Delayed Output Safety Relay
Schneider Electric XPSUAF33AP Preventa XPSU Cat. 4 Universal 48-240 V AC/DC 3 NO Safety Relay
Schneider Electric XPSUAF13AP Preventa XPSU Cat. 4 Universal 24 V AC/DC 3 NO Safety Relay
Schneider Electric XPSBAC34AP Preventa XPS E-Stop Guard Monitoring 48-240 V AC/DC 4 NO Safety Relay
Schneider Electric XPSBAC14AP Preventa XPS E-Stop Guard Monitoring 24 V AC/DC 4 NO Safety Relay
Schneider Electric TM3SAK6R Modicon TM3 Safety TM3SAK Cat 4 PL e SILCL 3 Safety Relay
Schneider Electric TM3SAFL5R Modicon TM3 Safety TM3SAFL Cat 3 PL d SILCL 2 Safety Relay
Schneider Electric TM3SAF5R Modicon TM3 Safety TM3SAF Cat 4 PL e SILCL 3 Safety Relay
Schneider Electric TM3SAC5R Modicon TM3 Safety TM3SAC Cat 3 PL d SILCL 2 Safety Relay
Siemens 3SK2942-2AA11 3SK2 Safety Relay
Siemens 3SK2941-2AA11 3SK2 Safety Relay
Siemens 3SK2511-2FA10 3SK2 Safety Relay
Safety relays from Siemens, Schneider Electric and ABB monitor emergency stop buttons, safety gates and light curtains and de-energize the machine on demand. The range includes Siemens 3SK1 and 3SK2, Schneider Preventa XPS and Modicon TM3 Safety modules, with contact ratings from 0.5 A to 16 A. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Siemens SIRIUS 3SK1 and 3SK2 safety relays and expansion modules.
- Schneider Preventa XPS emergency stop modules, including delayed output versions.
- Modicon TM3 Safety modules rated up to Cat 3 PL d and SILCL 2.
- ABB safety relay modules.
- Sentry safety products.
How to choose
- Required safety level: category, performance level (PL) and SIL claim limit under ISO 13849-1 and IEC 62061.
- Input type: emergency stop, two-channel guard, light curtain or two-hand control.
- Outputs: number of safety contacts and whether delayed outputs are needed.
- Supply voltage: 24 V DC or AC/DC supply ranges.
- Reset mode: manual or automatic start, with monitored reset where the risk assessment requires it.
FAQ
Can a standard relay be used for an emergency stop?
No. Safety circuits need forced-guided contacts and internal monitoring so that a single fault is detected. A standard relay does not provide this.
What do Cat 3 and PL d mean?
They describe the architecture and reliability of the safety function under ISO 13849-1. Your risk assessment sets the required level, and the relay must meet or exceed it.
Do you export safety relays?
Stoklink ships worldwide from Turkey, EXW. Lead time depends on distributor stock, and project quantities are quoted on request.