- Part number
- 3SK2941-2AA11
Description
About the 3SK2941-2AA11
About the 3SK2941-2AA11
The Siemens 3SK2941-2AA11 is a safety relay from the SENTRON/SIRIUS 3SK2 series. Starter kit for safety relay 3SK2 content: basic unit 3SK2 22.5 mm (3SK2112-2AA10), USB cable software SIRIUS Safety ES V17 Basic for free download. Supplied by Stoklink for industrial and commercial low-voltage applications.
Applications & Use Cases
The Siemens 3SK2941-2AA11 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3SK2 range it integrates with compatible SENTRON/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.
Specification
Full specification
General 6
| product brand name | SIRIUS |
|---|---|
| product category | Safety relay |
| product designation | Basic starter kit |
| design of the product | comprises 3SK2112-2AA10 basic unit, SIRIUS Safety Basic TIA for download and 3UF7941-0AA00-0 USB PC cable |
| suitability for use for monitoring of optoelectronic | Yes |
| protective devices according to IEC 61496-1 suitability for use: monitoring of floating sensors | Yes |
General technical data 29
| product function: EMERGENCY STOP function | Yes |
|---|---|
| product function: protective door monitoring | Yes |
| product function: protective door monitoring with tumbler | Yes |
| product function: muting, 2 sensor-parallel | Yes |
| product function: muting, 4 sensor-parallel | Yes |
| product function: muting, 4 sensor-sequential | Yes |
| product function: monitoring parameterizable | Yes |
| product function: evaluation: electro-sensitive protective equipment | Yes |
| product function: evaluation: selector switch | Yes |
| product function: pressure-sensitive mat monitoring | Yes |
| product function: evaluation: two-hand operator panel | Yes |
| product function: evaluation: enabling switch | Yes |
| product function: monitored start-up | Yes |
| product function: two-hand control according to EN 574 | Yes |
| configuration software required | Yes; Safety ES V1.0 and higher |
| number of function blocks typical | 50 |
| insulation voltage rated value | 50 V |
| degree of pollution | 3 |
| surge voltage resistance rated value | 800 V |
| protection class IP: of the enclosure | IP20 |
| protection class IP: of the terminal | IP20 |
| shock resistance | 15 g / 11 ms |
| vibration resistance according to IEC 60068-2-6 | 5 ... 500 Hz: 0.75 mm |
| operating frequency maximum | 2 000 1/h |
| reference code according to IEC 81346-2 | F |
| Substance Prohibitance (day/month/year) | 07/01/2006 |
| SVHC substance name | Lead CAS-No. 7439-92-1 Lead monoxide (lead oxide) CAS-No. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868- 10-5 Melamine CAS-No. 108-78-1 |
| product function suitable for AS-i Power24V | No |
| product function diagnostics with CTT2 device | No |
Ambient conditions 6
| installation altitude at height above sea level maximum | 4 000 m |
|---|---|
| ambient temperature: during operation | -25 ... +60 °C |
| ambient temperature: during storage | -40 ... +80 °C |
| ambient temperature: during transport | -40 ... +80 °C |
| relative humidity during operation | 10 ... 95 % |
| air pressure according to SN 31205 | 90 ... 106 kPa |
Show all 124 specifications ↓ Show less ↑83 more values in Identification, Electromagnetic compatibility, Safety related data, IEC 62061, ISO 13849, IEC 61508, Electrical Safety, Inputs/ Outputs, Communication/ Protocol, Control circuit/ Control, Installation/ mounting/ dimensions, Connections/ Terminals, Logistics.
Identification 9
| Part number | 3SK2941-2AA11 |
|---|---|
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4047621095400 |
| ETIM class | EC001449 |
| eCl@ss | 27371819 |
Electromagnetic compatibility 4
| EMC emitted interference according to IEC 60947-1 | class A |
|---|---|
| conducted interference: due to burst according to IEC 61000-4-4 | 2 kV (power ports) / 1 kV (signal ports) |
| field-based interference according to IEC 61000-4-3 | 10 V/m |
| electrostatic discharge according to IEC 61000-4-2 | 4 kV contact discharge / 8 kV air discharge |
IEC 62061 3
| SIL Claim Limit (subsystem) according to EN 62061 | 3 |
|---|---|
| Safety Integrity Level (SIL): according to IEC 62061 | SIL 3 |
| PFHD with high demand rate: according to IEC 62061 | 1E-8 1/h |
ISO 13849 3
| performance level (PL) according to EN ISO 13849-1 | e |
|---|---|
| category according to EN ISO 13849-1 | 4 |
| performance level (PL): according to ISO 13849-1 | PL e |
IEC 61508 4
| Safety Integrity Level (SIL): according to IEC 61508 | 3 |
|---|---|
| PFDavg with low demand rate according to IEC 61508 | 1.5E-5 |
| hardware fault tolerance: according to IEC 61508 | 1 |
| T1 value: for proof test interval or service life according to IEC 61508 | 20 a |
Electrical Safety 1
| touch protection against electrical shock | finger-safe |
|---|
Inputs/ Outputs 29
| product function: parameterizable inputs | Yes |
|---|---|
| product function: parameterizable outputs | Yes |
| product function: at the digital outputs short-circuit protection | Yes |
| number of inputs: safety-related | 10 |
| number of inputs: non-safety-related | 0 |
| input delay time | 0 ... 150 ms |
| type of digital inputs according to IEC 60947-1 | Type 1 |
| ingress aquisition time at digital input maximum | 60 ms |
| input delay time at digital input maximum | 150 ms |
| input voltage at digital input at DC rated value | 24 V |
| input current at digital input: for signal typical | 2.6 mA |
| number of outputs: safety-related 2-channel | 2 |
| number of outputs: for testing contact-based sensors | 2 |
| number of outputs as contact-affected switching element safety-related: 1-channel | 0 |
| number of outputs as contact-less semiconductor switching element: safety-related 2-channel | 2 |
| design of the contactless switching element safety-related | P potential |
| recovery time of the safe outputs | 0 ms |
| readback time maximum | 400 ms |
| light test period | 3 ms |
| dark period of the common drivers | 3 ms |
| switching capacity current of semiconductor outputs at DC-13 at 24 V | 4 A |
| residual current: maximum | 0.1 mA |
| residual current: at digital output with signal maximum | 0.1 mA |
| total current maximum | 6.5 A |
| voltage drop maximum | 0.5 V |
| to the inputs: shielded maximum | 1 000 m |
| to the inputs: unshielded maximum | 600 m |
| to the outputs: shielded maximum | 1 000 m |
| to the outputs: unshielded maximum | 600 m |
Communication/ Protocol 3
| protocol optional is supported: PROFIBUS DP protocol | Yes; when using the DP interface module; 64 bit cyclical data |
|---|---|
| protocol optional is supported: PROFINET IO protocol | Yes; when using the PN interface module; 64-bit cyclic data |
| protocol is supported AS-Interface protocol | No |
Control circuit/ Control 6
| type of voltage | DC |
|---|---|
| control supply voltage rated value | 24 V |
| operating range factor control supply voltage rated value at DC: initial value | 0.85 |
| inrush current peak: at 24 V | 10 A |
| duration of inrush current peak: at 24 V | 1 ms |
| operating power rated value | 2.5 W |
Installation/ mounting/ dimensions 5
| mounting position | any |
|---|---|
| fastening method | Snap-mounted to DIN rail or screw-mounted with additional push-in lug |
| height | 100 mm |
| width | 22.5 mm |
| depth | 124.5 mm |
Connections/ Terminals 8
| product function removable terminal | Yes |
|---|---|
| type of electrical connection | spring-loaded terminal (push-in) |
| type of connectable conductor cross-sections: solid | 1x (0.5 ... 1.5 mm2), 2x (0.5 ... 1.5 mm2) |
| type of connectable conductor cross-sections: finely stranded with core end processing | 1x (0.5 ... 1.0 mm2), 2x (0.5 ... 1.0 mm2) |
| type of connectable conductor cross-sections: for AWG cables solid | 1x (20 ... 16), 2x (20 ... 16) |
| connectable conductor cross-section finely stranded with core end processing | 0.5 ... 1 mm2 |
| AWG number as coded connectable conductor cross section: solid | 20 ... 16 |
| AWG number as coded connectable conductor cross section: stranded | 20 ... 16 |
Logistics 6
| Net weight | 0.45 kg |
|---|---|
| Package dimensions | 315 × 186 × 158 mm |
| Country of origin | DE |
| Shipping weight | 0.95 kg |
| Dispatch | 25 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 31 Oct 2026
Documents
Documents for 3SK2941-2AA11 1
-
Datasheet
ProductDownload PDF: Product data sheet 3SK2941-2AA11
Product data sheet 3SK2941-2AA11
Quick answers
Questions about the 3SK2941-2AA11
Which control voltage does 3SK2941-2AA11 need?
The control voltage range of 3SK2941-2AA11 is 24 V.
What is the HS code of 3SK2941-2AA11 for customs?
The tariff (HS) code on file for 3SK2941-2AA11 is 85371098.
What is the EAN of 3SK2941-2AA11?
The EAN (GTIN) of 3SK2941-2AA11 is 4047621095400.
How is 3SK2941-2AA11 delivered, and how fast?
3SK2941-2AA11 ships worldwide by express courier, with tracking. Shipping and import duties calculated at checkout · nothing to pay on delivery. Stock items are dispatched within 1–2 business days.
Reviews
Customer reviews
Series
Siemens 3SK2
- Brand
- Siemens
- Series
- 3SK2