Part number
XPSUEP34AP
$230.86 On request Dispatch — · From TürkiyeGet a Quote
Harmony Safety Automation

Schneider Electric XPSUEP34AP Preventa XPSU Cat. 4 48-240 V AC/DC Expansion 4 NO Safety Relay

Preventa XPSU safety output expansion module, 4 NO + 2 NC, 48-240 V AC/DC, Cat. 4 / PLe, SIL 3.

Rated current
8 A
Rated operational voltage
48–240–DC V DC
Description

About the XPSUEP34AP

The Schneider Electric XPSUEP34AP is a Preventa XPSU expansion module that adds 4 redundant NO safety outputs and 2 single NC outputs to an XPSUAF, XPSUAK, XPSUAT, XPSUDN or XPSUS base module via the safety extension bus. Powered at 48-240 V AC/DC, it reaches Category 4 / PLe per ISO 13849-1 and SIL 3 per IEC 61508. It cannot operate without a compatible XPSU base module.

Certifications & Standards

  • TÜV
  • cULus
  • IEC 60947-5-1
  • IEC 61508
  • ISO 13849-1
  • IEC 62061

Selection Notes

Choose the XPSUEP34AP when the base safety module it extends runs on the 48-240 V AC/DC universal supply — for example an XPSUAF33AP, XPSUAT33A3AP or XPSUDN33AP that has run out of NO/NC contacts for the contactors or drives it needs to switch. It adds the same 4 redundant NO + 2 single NC contact set as the 24 V XPSUEP14AP, matched to the higher voltage class so the expansion module's supply doesn't become the odd one out on the DIN rail. It carries no safety inputs of its own.

Specification

Full specification

59 values · Last verified 30 Oct 2026

Main 10

Range of product Harmony Safety Automation
Product or component type Safety module
Safety module name XPSUEP
Safety module application For extending number of safety contacts
Function of module Safety output extension
Safety level Can reach PL e/category 4 for normally open relay contact conforming to ISO 13849-1, Can reach SILCL 3 for normally open relay contact conforming to IEC 62061, Can reach SIL 3 for normally open relay contact conforming to IEC 61508, Can reach PL c/category 1 for normally closed relay contact conforming to ISO 13849-1, Can reach SILCL 1 for normally closed relay contact conforming to IEC 62061, Can reach SIL 1 for normally closed relay contact conforming to IEC 61508
Safety reliability data MTTFd > 30 years conforming to ISO 13849-1, Dcavg >= 99 % conforming to ISO 13849-1, PFHd = 1.61E-09 conforming to ISO 13849-1, HFT = 1 conforming to IEC 62061, PFHd = 1.61E-09 conforming to IEC 62061, SFF > 99% conforming to IEC 62061, HFT = 1 conforming to IEC 61508-1, PFHd = 1.61E-09 conforming to IEC 61508-1, SFF > 99% conforming to IEC 61508-1, Type = B conforming to IEC 61508-1
Electrical circuit type Addition to Preventa XPSU base module
Connections - terminals Removable screw terminal block, 0.2...2.5 mm² solid or flexible, Removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor, Removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor, Removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel, Removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
[Us] rated supply voltage 48...240 V AC/DC - 10...10 %

Complementary 21

Power consumption in W 2 W 48 V DC
Power consumption in VA 6.5 VA 240 V AC 50/60 Hz
Input protection type Internal, electronic
safety outputs 4 NO redundant, 2 NC single
safety inputs 0 extension bus 24 V DC 5 mA
Maximum line resistance 60 Ohm
Input compatibility Normally closed circuit conforming to ISO 14119, XC limit switch conforming to ISO 14119, Mechanical contact conforming to ISO 14119, Normally closed circuit conforming to ISO 13850, Antivalent pair conforming to ISO 14119, OSSD pair conforming to IEC 61496-1-2, 3-wire proximity sensors PNP
[Ie] rated operational current 5 A AC-1 for normally open relay contact, 3 A AC-15 for normally open relay contact, 5 A DC-1 for normally open relay contact, 3 A DC-13 for normally open relay contact
[Ith] conventional free air thermal current 8 A
Associated fuse rating 10 A gG for NO relay output circuit conforming to IEC 60947-1, 4 A gG for NC relay output circuit conforming to IEC 60947-1
Minimum output current 10 mA for relay output
Minimum output voltage 12 V for relay output
Maximum response time on input open 20 ms
[Ui] rated insulation voltage 250 V (pollution degree 2) conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage 4 kV overvoltage category II conforming to IEC 60947-1
Local signalling LED (green) for power ON, LED (red) for error, LED (yellow) for safety output status
Mounting support 35 mm symmetrical DIN rail
Depth 120 mm
Height 100 mm
Width 22.5 mm
Net weight 0.200 kg

Environment 5

Standards IEC 60947-5-1, IEC 61508-1 functional safety standard, IEC 61508-2 functional safety standard, IEC 61508-3 functional safety standard, IEC 61508-4 functional safety standard, IEC 61508-5 functional safety standard, IEC 61508-6 functional safety standard, IEC 61508-7 functional safety standard, ISO 13849-1 functional safety standard, IEC 62061 functional safety standard
Product certifications TÜV, cULus
IP degree of protection IP20 (terminals) conforming to IEC 60529, IP40 (housing) conforming to IEC 60529, IP54 (mounting area) conforming to IEC 60529
Ambient air temperature for storage -25…85 °C
Relative humidity 5…95 % non-condensing
Show all 59 specifications ↓ Show less ↑23 more values in Identification, Contractual warranty, Logistics.

Identification 6

Part number XPSUEP34AP
Brand Schneider Electric
Condition New, factory sealed
Source Schneider Electric and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production

Contractual warranty 1

Warranty (in months) 18

Logistics 16

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 6.500 cm
Package 1 Width 13.500 cm
Package 1 Length 15.500 cm
Package 1 Weight 318.000 g
Unit Type of Package 2 S03
Number of Units in Package 2 16
Package 2 Height 30.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 5.660 kg
Shipping weight 0.2 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 30 Oct 2026

Documents

Documents for XPSUEP34AP

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • cULus
  • IEC 60947-5-1
  • IEC 61508-1 functional safety standard
  • IEC 61508-2 functional safety standard
  • IEC 61508-3 functional safety standard
  • IEC 61508-4 functional safety standard
  • IEC 61508-5 functional safety standard
  • IEC 61508-6 functional safety standard
  • IEC 61508-7 functional safety standard
  • ISO 13849-1 functional safety standard
  • IEC 62061 functional safety standard
Quick answers

Questions about the XPSUEP34AP

What is the rated current of XPSUEP34AP?

The rated current of XPSUEP34AP is 8 A.

Which supply voltage is XPSUEP34AP rated for?

The rated operational voltage of XPSUEP34AP is 48–240–DC V DC.

What is the HS code of XPSUEP34AP for customs?

The tariff (HS) code on file for XPSUEP34AP is 853641.

Where does XPSUEP34AP ship from, and how fast?

XPSUEP34AP ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Reviews

Customer reviews

Series

Schneider Electric Harmony Safety Automation

Brand
Schneider Electric
Series
Harmony Safety Automation
$230.86 On request
Get a Quote
Quote

Get a Quote

Genuine parts

Genuine, factory-sealed parts

Schneider Electric · XPSUEP34AP

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Schneider Electric and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart