- Home
- All Collections
- Circuit Breakers & Protection
Circuit Breakers & Protection
Circuit Breakers & Protection Categories
Circuit Breakers & Protection
Schneider Electric C25F3TM250 NSX250F 3P 250A 36kA Moulded Case Circuit Breaker
Schneider Electric C25F3TM200 NSX250F 3P 200A 36kA Moulded Case Circuit Breaker
Schneider Electric C25F3MA220 NSX250F 3P 220A 36kA ComPacT Moulded Case Circuit Breaker
Schneider Electric C25F32D250 NSX250F 3-Pole 250A 36kA 415V ComPacT Molded Case Circuit Breaker
Schneider Electric C16S2TM125 ComPacT NSX160S 2P 125 A 70 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C16N6TM160 NSX160N 4P 160A 50kA Moulded Case Circuit Breaker
Schneider Electric C16N6TM125 ComPacT NSX160N 4P 125 A 50 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C16N3TM160 NSX160N 3P 160A 50kA Moulded Case Circuit Breaker
Schneider Electric C16N3TM125 NSX160N 3P 125A 50kA Moulded Case Circuit Breaker
Schneider Electric C16N3MA150 ComPacT NSX160N 3P 150 A 50 kA MA Fixed Moulded Case Circuit Breaker
Schneider Electric C16N32D160 NSX160N 3-Pole 160A 50kA Compact NSX Moulded Case Circuit Breaker
Schneider Electric C16M2TM160 ComPacT NSX160M 2P 160 A 25 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C16M2TM125 ComPacT NSX160M 2P 125 A 25 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C16M1TM160 ComPacT NSX160M 1P 160 A 40 kA at 240 V TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C16H6TM160 ComPacT NSX160H 4P 160 A 70 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C16H3TM160 ComPacT NSX160H 3P 160 A 70 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C16H3TM125 ComPacT NSX160H 3P 125 A 70 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C16H3MA150 ComPacT NSX160H 3P 150 A 70 kA MA Fixed Moulded Case Circuit Breaker
Schneider Electric C16H32M150 NSX160H 3-Pole 150A 70kA 415V Moulded Case Circuit Breaker
Schneider Electric C16F6TM160 NSX160F 4P 160A 36kA 415V Molded Case Circuit Breaker
Circuit breakers and protection devices from ABB, Siemens, Schneider Electric and Mersen cover the full low-voltage protection chain, from miniature circuit breakers to air circuit breakers up to 6300 A. The range includes MCB, MCCB, ACB, residual current devices, arc fault detection devices and surge protective devices in 1 to 4 poles, with more than 4,500 listed products. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Miniature Circuit Breakers (MCB) – DIN-rail overcurrent protection for final circuits and distribution boards.
- Molded Case Circuit Breakers (MCCB) – feeder and motor-circuit protection with adjustable trip units.
- Air Circuit Breakers (ACB) – main incomer and bus-tie breakers from 630 A to 6300 A.
- Residual Current Devices (RCD) – earth-leakage protection against shock and fire.
- Arc Fault Detection Devices (AFDD) – detection of series and parallel arcs in final circuits.
- Surge Protective Devices (SPD) – protection of installations against transient overvoltage.
How to choose
- Rated current and pole count, matched to the load and the neutral arrangement.
- Breaking capacity at the installation voltage, at or above the prospective short-circuit current.
- Standard: IEC 60898-1 for household and similar MCBs, IEC 60947-2 for industrial breakers, IEC 61008 and 61009 for RCDs.
- Trip characteristic or trip unit type, and coordination with upstream and downstream devices.
FAQ
What is the difference between an MCB and an MCCB?
An MCB is a DIN-rail breaker for final circuits, usually with fixed thermal-magnetic tripping. An MCCB covers higher currents and short-circuit levels and often has adjustable or electronic trip units.
Do I need an RCD in addition to a circuit breaker?
Yes, where earth-leakage protection is required. A standard breaker protects against overload and short circuit, while an RCD detects leakage current to earth.
Can you ship circuit breakers outside Turkey?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.