- Home
- All Collections
- Power Quality, Metering & Power Supplies
Power Quality, Metering & Power Supplies
Power Quality, Metering & Power Supplies Categories
Power Quality, Metering & Power Supplies
Siemens 6EP3323-7SB00-0AX0 SITOP PSU6200 12 V/7 A Stabilized Power Supply
Siemens 6EP3323-0SA00-0BY0 SITOP PSU3600 Dual 2x15V/3.5A Power Supply
Siemens 6EP3322-6SB10-0AY0 LOGO!Power 100-240V AC / 15V DC 4A Power Supply
Siemens 6EP3322-6SB00-0AY0 SITOP LOGO!Power 100-240V AC 12V/4.5A Power Supply
Siemens 6EP3321-7SB00-0AX0 SITOP PSU6200 120-240V AC 12V 2A Power Supply
Siemens 6EP3321-6SB10-0AY0 LOGO!Power 100-240V AC 15V 1.9A Power Supply
Siemens 6EP3321-6SB00-0AY0 LOGO!Power 12 V/1.9 A Stabilized Power Supply
Siemens 6EP3320-6SB00-0AY0 LOGO!Power 100-240V AC 12V 0.9A Power Supply
Siemens 6EP3311-6SB00-0AY0 LOGO!Power 5 V/6.3 A Stabilized Power Supply
Siemens 6EP3310-6SB00-0AY0 SITOP LOGO!Power 5V DC 3A Power Supply
Siemens 6EP3234-0TA00-0AY0 SITOP PSU3400 48V to 24V 10A DC/DC Converter
Siemens 6EP3233-0TA00-0AY0 SITOP PSU3400 48V-24V 5A DC/DC Converter
Siemens 6EP3134-0TA00-0AY0 SITOP PSU3400 24V to 24V 10A DC/DC Converter
Siemens 6EP3124-0TA00-0AY0 SITOP PSU3400 24V to 12V 15A DC/DC Converter
Siemens 6EP1964-2BA00 SITOP PSE202U 24V DC 10A Decoupling Redundancy Module
Siemens 6EP1961-3BA21 SITOP PSE202U 24V/40A Redundancy Module
Siemens 6EP1961-3BA01 SITOP PSE201U 24V DC 40A Power Supply Buffer Module
Siemens 6EP1961-2BA61 SITOP PSE200U 4x3A NEC Class 2 Per-Output Status Selectivity Module
Siemens 6EP1961-2BA51 SITOP PSE200U 4x3A NEC Class 2 Common Signal Selectivity Module
Siemens 6EP1961-2BA41 SITOP PSE200U 4x10A 24V DC Power Supply Selectivity Module
Power quality, metering and power supplies from ABB, Siemens and Schneider Electric: over 700 products for measuring energy, supplying control circuits and correcting power factor in low-voltage panels. The range covers rated currents from under 1 A to 6000 A and DC supplies up to 98.5 kW. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Energy Meters & Power Analyzers – multifunction meters, energy analyzers and wireless energy sensors for monitoring load and consumption.
- Current Transformers – primary-to-5 A and low-voltage output transformers that feed meters, relays and analyzers.
- Power Supplies – 24 V DC DIN rail units, DC UPS and buffer modules, redundancy and selectivity modules.
- Power Factor Correction – capacitors and related components that reduce reactive power in the installation.
How to choose
- Define the job first: billing-grade energy metering, power quality analysis, control power or reactive compensation each need a different product family.
- Match ratings to the circuit. Meters and transformers follow the primary current and system voltage, supplies follow the load current at 24 V DC, capacitors follow kvar and network voltage.
- Check accuracy class for metering points. Class 0.2S, 0.5 and 1 are common choices depending on whether the data is used for billing or for monitoring.
- Confirm mounting and communication: DIN rail or panel cut-out, Modbus or Ethernet interfaces, and input voltage range of the supply.
FAQ
What is the difference between an energy meter and a power analyzer?
An energy meter mainly records kWh consumption. A power analyzer also measures harmonics, power factor, demand and waveform data, so it suits power quality studies.
Do I need current transformers with every meter?
Not always. Direct-connect meters take current up to their rating. Above that, a meter normally works with current transformers, typically with a 5 A secondary.
Do you ship these products outside Turkey?
Yes. Stoklink ships worldwide from Turkey under EXW terms. Lead time depends on distributor stock, and bulk quotes are available on request.