SITOP PSU3400 DC/DC converter, 48V in, 24V/5A out, DIN rail, 92% efficiency.
The Siemens 6EP3233-0TA00-0AY0 SITOP PSU3400 is a DC/DC converter that steps a 48 V DC (28-60 V range) input down to a stabilized 24 V DC output at 5 A, adjustable up to 6 A. It reaches 92% efficiency and fits a 32 mm DIN-rail footprint for battery- or 48 V-bus-fed control cabinets.
The 48 V DC input (28-60 V range) is what separates this PSU3400 unit from the AC-mains SITOP power supplies — choose it where the cabinet already runs a 48 V DC bus, such as a telecom-style battery system, rather than adding an AC feed. The output is adjustable 24-28 V via potentiometer, useful for compensating voltage drop on long 24 V DC runs instead of a fixed-output sibling. Two units can be connected in parallel to raise available current beyond the single-unit 5 A/6 A rating without moving to a higher-power PSU model.
48 V DC bus-fed control panels, telecom or battery-backed cabinets, and machine control needing a regulated 24 V feed from an intermediate 48 V rail.
| product brand name | SITOP |
|---|---|
| product type designation | PSU3400 |
| product designation | Power supply SITOP DC-DC converter |
| type of current supply | 24 V/5 A |
| type of the power supply network | DC voltage |
|---|---|
| voltage curve at input | DC |
| supply voltage at AC | Startup as of 36 V, derating necessary for 28 ... 36 V DC |
| supply voltage at DC | 48 V |
| input voltage at DC | 28 ... 60 V |
| wide range input | No |
| overvoltage overload capability | - |
| buffering time for rated value of the output current in the event of power failure minimum | 5 ms |
| operating condition of the mains buffering | at Vin = 48 V |
| input current: at rated input voltage 48 V | 2.7 A |
| current limitation of inrush current at 25 °C maximum | 15 A |
| I2t value maximum | 0.12 A2·s |
| fuse protection type | 15 A (not accessible), breaking capacity 100 A |
| fuse protection type in the feeder | Recommended miniature circuit breaker: 16 A characteristic B or C |
| voltage curve at output | Controlled, isolated DC voltage |
|---|---|
| product function output voltage controlled | Yes |
| product function output voltage stabilized | Yes |
| output voltage at DC rated value | 24 V |
| output voltage: at output 1 at DC rated value | 24 V |
| output voltage: at output 1 at DC | 24 V |
| output voltage adjustable | Yes; via potentiometer |
| adjustable output voltage | 24 ... 28 V |
| relative overall tolerance of the voltage | 1% |
| relative control precision of the output voltage: on slow fluctuation of input voltage | 0.1 % |
| residual ripple: maximum | 150 mV |
| residual ripple: typical | 70 mV |
| voltage peak: maximum | 250 mV |
| voltage peak: typical | 220 mV |
| display version for normal operation | Green LED for 24 V OK |
| behavior of the output voltage when switching on | No overshoot of Vout (soft start) |
| response delay maximum | 0.5 s |
| voltage increase time of the output voltage: typical | 10 ms |
| voltage increase time of the output voltage: maximum | 20 ms |
| output current: rated value | 5 A |
| output current: rated range | 0 ... 6 A; 6 A up to +40°C; +60 ... +70 °C: Derating 2%/K |
| supplied active power typical | 130 W |
| bridging of equipment | Yes |
| number of parallel-switched equipment resources for increasing the power | 2 |
| Part number | 6EP3233-0TA00-0AY0 |
|---|---|
| Type designation | PSU3400 |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4025515155522 |
| ETIM class | EC002540 |
| eCl@ss | 27040701 |
| efficiency in percent | 92 % |
|---|---|
| power loss [W]: at rated output voltage for rated value of the output current typical | 10 W |
| power loss [W]: during no-load operation maximum | 1.5 W |
| relative control precision of the output voltage with rapid fluctuation of the input voltage by +/- 15% typical | 0.3 % |
|---|---|
| relative control precision of the output voltage load step of resistive load 50/100/50 % typical | 2% |
| setting time: load step 50 to 100% typical | 1 ms |
| setting time: load step 100 to 50% typical | 1 ms |
| design of the overvoltage protection | Ua < 35 V |
|---|---|
| property of the output short-circuit proof | Yes |
| design of short-circuit protection | Electronic shutdown, automatic restart |
| typical | 6.5 A |
| display version for overload and short circuit | LED yellow for "overload" |
| galvanic isolation between input and output | Yes |
|---|---|
| galvanic isolation | Output voltage: SELV, ES1 (IEC 62368-1), DVC As (IEC 61204-7) |
| operating resource protection class | Class III |
| protection class IP | IP20 |
| standard: for emitted interference | EN 61000-6-3 |
|---|---|
| standard: for mains harmonics limitation | not applicable |
| standard: for interference immunity | EN 61000-6-2 |
| certificate of suitability: CE marking | Yes |
|---|---|
| certificate of suitability: UL approval | Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259 |
| certificate of suitability: EAC approval | Yes |
| certificate of suitability: Regulatory Compliance Mark (RCM) | Yes |
| certificate of suitability: NEC Class 2 | No |
| type of certification: CB-certificate | Yes |
| MTBF at 40 °C | 1 965 061 h |
| standards, specifications, approvals hazardous environments certificate of suitability: IECEx | No |
| shipbuilding approval | Yes |
|---|---|
| Marine classification association: American Bureau of Shipping Europe Ltd. (ABS) | Yes |
| Marine classification association: French marine classification society (BV) | No |
| Marine classification association: Det Norske Veritas (DNV) | Yes |
| Marine classification association: Lloyds Register of Shipping (LRS) | No |
| ambient temperature: during operation | -25 ... +70 °C; with natural convection |
|---|---|
| ambient temperature: during transport | -40 ... +85 °C |
| ambient temperature: during storage | -40 ... +85 °C |
| environmental category according to IEC 60721 | Climate class 3K3, 5 ... 95% no condensation |
| type of electrical connection | screw terminal |
|---|---|
| at input | L, N, FE: 1 screw terminal each for 0.5 ... 2.5 mm2 single-core/finely stranded |
| at output | +, -: 2 screw terminals each for 0.5 ... 2.5 mm2 |
| width × height × depth of the enclosure | 32 × 100 × 100 mm |
|---|---|
| installation width × mounting height | 32 mm × 200 mm |
| required spacing: top | 50 mm |
| required spacing: bottom | 50 mm |
| required spacing: left | 0 mm |
| required spacing: right | 0 mm |
| fastening method | Snaps onto DIN rail EN 60715 35x7.5/15 |
| DIN-rail mounting | Yes |
| S7 rail mounting | No |
| wall mounting | No |
| housing can be lined up | Yes |
| electrical accessories | Buffer module |
|---|
| other information | Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified) |
|---|
| eClass | 16 27-04-07-01 |
|---|---|
| ETIM | 10 EC002540 |
| IDEA | 4 4130 |
| UNSPSC | 15 39-12-10-04 |
| Net weight | 0.32 kg |
|---|---|
| Country of origin | HU |
| Shipping weight | 0.82 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of PSU3400 is 5 A.
The rated motor power of PSU3400 is 10 W kW.
The tariff (HS) code on file for PSU3400 is 85044095.
The EAN (GTIN) of PSU3400 is 4025515155522.
PSU3400 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.