- Home
- Power Quality, Metering & Power Supplies
- Siemens 6EP3321-7SB00-0AX0 SITOP PSU6200 120-240V AC 12V 2A Power Supply Siemens 6EP3321-7SB00-0AX0 SITOP PSU6200 120-240V AC 12V 2A Power Supply
Siemens 6EP3321-7SB00-0AX0 SITOP PSU6200 120-240V AC 12V 2A Power Supply
Siemens 6EP3321-7SB00-0AX0 SITOP PSU6200 120-240V AC 12V 2A Power Supply
Get Quote
- Description
The Siemens 6EP3321-7SB00-0AX0 is a SITOP PSU6200 stabilized power supply that converts a 120-240 V AC (or 120-240 V DC) input into a regulated 12 V DC output at 2 A, adjustable up to 12.9 V via potentiometer. It reaches 83.3% efficiency, holds a 150 ms minimum buffering time at rated output, and connects through push-in terminals on a 25 mm DIN-rail enclosure.
Technical Specifications
| Order Number | 6EP3321-7SB00-0AX0 |
| Brand | Siemens |
| Series | SITOP PSU6200 |
| Product Designation | PSU6200 |
| Input Voltage (AC) | 120 ... 240 V AC, 85 ... 264 V full range |
| Input Voltage (DC) | 120 ... 240 V DC, 110 ... 275 V range |
| Line Frequency | 50/60 Hz (47 ... 63 Hz) |
| Input Current (at 120V) | 0.45 A |
| Input Current (at 240V) | 0.25 A |
| Output Voltage (rated) | 12 V DC |
| Output Voltage Adjustable | 10.5 ... 12.9 V, max 24 W |
| Output Current (rated) | 2 A |
| Output Power (typical) | 24 W |
| Efficiency | 83.3% |
| Power Loss (typical) | 5 W |
| Buffering Time (min, at rated output) | 150 ms |
| Protection Class IP | IP20 |
| Operating Resource Protection Class | Class I |
| Leakage Current (max) | 3.5 mA |
| Galvanic Isolation | Yes, output: SELV, ES1 (IEC 62368-1) |
| Ambient Temperature (Operation) | -25 ... +70 degC |
| Enclosure Dimensions (W x H x D) | 25 x 100 x 88 mm |
| Connection Type | Push-in terminals |
| Mounting | DIN rail EN 60715 35x7.5/15 |
| Net Weight | 0.2 kg |
| Country of Origin | RO |
Certifications & Standards
- CE
- UKCA
- EAC
- RCM
- SEMI F47
- CB
- Shipbuilding
- ABS
- DNV
- EPD
Selection Notes
The 150 ms minimum buffering time at rated output is markedly longer than the LOGO!Power line's hold-up, making the PSU6200 the better choice when a brief mains dip must not drop the 12 V rail even momentarily. Class I construction with a 3.5 mA max leakage current is a different safety class from the Class II LOGO!Power units, so grounding needs to be designed in rather than assumed. Push-in terminals instead of screw terminals speed up wiring on the input and output sides, and the 120-240 V AC/DC dual-mode input covers both AC mains and DC-bus feeding without a separate model.
Applications
Powers 12 V DC loads needing a longer power-fail ride-through than a basic supply provides - remote I/O, small HMI panels, or sensor networks - in cabinets already using SIMATIC ET 200SP-style push-in wiring, since the module also lists an ET 200SP identification label as an accessory.