Siemens 3RT2625-1AP05 3RT2 24A 3P 400V Contactor
Siemens 3RT2617-1AP03 3RT2 18A 3P 400V Contactor
Siemens 3RT2448-1AP00 3RT2 160A 3P 690V Contactor
Siemens 3RT2446-1AP00 3RT2 140A 3P 690V Contactor
Siemens 3RT2348-1AP00 3RT2 160A 4P 400V Contactor
Siemens 3RT2346-1AP00 3RT2 140A 4P 400V Contactor
Siemens 3RT2337-1AP00 3RT2 110A 4P 400V Contactor
Siemens 3RT2336-1AP00 3RT2 60A 4P 400V Contactor
Siemens 3RT2327-1AP00 3RT2 50A 4P 400V Contactor
Siemens 3RT2326-1AP00 3RT2 40A 4P 400V Contactor
Siemens 3RT2325-1AP00 3RT2 35A 4P 400V Contactor
Siemens 3RT2317-1AP00 3RT2 22A 4P 400V Contactor
Siemens 3RT2316-1AP00 3RT2 18A 4P 400V Contactor
Siemens 3RT2047-1NB30 3RT2 110A 3P 400V Contactor
Siemens 3RT2047-1AP00 3RT2 110A 3P 400V Contactor
Siemens 3RT2046-1NB30 3RT2 95A 3P 400V Contactor
Siemens 3RT2046-1AP00 3RT2 95A 3P 400V Contactor
Siemens 3RT2045-1NB30 3RT2 80A 3P 400V Contactor
Siemens 3RT2045-1AP00 3RT2 80A 3P 400V Contactor
Siemens 3RT2038-1NB30 3RT2 80A 3P 400V Contactor
Power contactors (AC-3) from ABB, Schneider Electric and Siemens start and stop three-phase motors and switch heavy loads. The range covers over 650 products from 6 A to 2650 A, with motor ratings from 2.2 kW to 450 kW, mostly in 3 and 4 pole versions. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- ABB AF Contactors – 3 and 4 pole AF series with wide-range AC/DC coils.
- Schneider TeSys Deca Contactors – the largest series here, from 9 A to 200 A.
- Schneider TeSys Giga Contactors – high-current frames from 115 A to 800 A.
- Schneider TeSys K Contactors – compact contactors for 6 A to 16 A.
- Schneider Easy TeSys Contactors – general-purpose contactors from 6 A to 630 A.
- Siemens SIRIUS 3RT2 Contactors and Siemens SIRIUS 3RT1 Contactors – SIRIUS frames from small to very large.
How to choose
- Motor power and current in AC-3 at your supply voltage. Do not size from the AC-1 value.
- Pole count: 3P for motors, 4P where the neutral is switched.
- Coil voltage and type, AC or DC, against the control supply.
- Short-circuit protection and overload relay matched to the contactor, following the manufacturer's coordination tables.
- Auxiliary contact needs and whether add-on blocks fit the frame.
FAQ
What does AC-3 mean on a contactor?
AC-3 is the IEC 60947-4-1 category for starting and stopping squirrel-cage motors. Ratings in AC-3 are usually lower than AC-1 for the same frame.
Can I replace a contactor with another brand?
Check rated current in AC-3, pole count, coil voltage and mounting dimensions. Auxiliary contacts and coordination with the overload relay must also match.
Do you ship contactors outside Turkey?