- Home
- All Collections
- Motor Control & Protection
Motor Control & Protection
Motor Control & Protection Categories
Motor Control & Protection
ABB 1SFA897101R7000 PSE18-600-70 18A 208-600V AC 3P 7.5kW Soft Starter
ABB 1SFA897105R7000 PSE45-600-70 45A 208-600V AC 3P 22kW Soft Starter
ABB 1SFA897106R7000 PSE60-600-70 3P 60A 208-600V AC 30kW Soft Starter
ABB 1SFA896115R7000 PSR105-600-70 105A 3P 208-600V AC 55kW Soft Starter
ABB 1SFA897104R7000 PSE37-600-70 37A 3P 208-600V AC 18.5kW Soft Starter
ABB 1SFA897107R7000 PSE72-600-70 72A 208-600V AC 3P 37kW Soft Starter
ABB 1SFA896114R7000 PSR85-600-70 85A 208-600V AC 3P 45kW Softstarter
ABB 1SFA896113R7000 PSR72-600-70 72A 3P 208-600V AC 37kW Softstarter
ABB 1SFA897102R7000 PSE25-600-70 25A 208-600V AC 3P 11kW Soft Starter
ABB 1SFA897103R7000 PSE30-600-70 30A 208-600V AC 3P 15kW Soft Starter
ABB 1SFA896109R7000 PSR30-600-70 30A 208-600V AC 3P 15kW Soft Starter
ABB 1SFA896103R7000 PSR3-600-70 3.9A 208-600V AC 3P 1.5kW Softstarter
ABB 1SFA896105R7000 PSR9-600-70 9A 208-600V AC 3P 4kW Softstarter
ABB 1SFA896104R7000 PSR6-600-70 6.8A 208-600V AC 3P Softstarter
ABB 1SFA896112R7000 PSR60-600-70 60A 3P 208-600V AC 30kW Softstarter
ABB 1SFA896108R7000 PSR25-600-70 25A 3P 208-600V AC 11kW Soft Starter
ABB 1SFA896106R7000 PSR12-600-70 12A 3P 208-600V AC Softstarter
ABB 1SFA896111R7000 PSR45-600-70 45A 3P 208-600V AC 22kW Softstarter
ABB 1SFA896110R7000 PSR37-600-70 37A 208-600V AC 3P 18.5kW Softstarter
ABB 1SFA896107R7000 PSR16-600-70 16A 3P 208-600V AC 7.5kW Softstarter
Motor control and protection equipment from ABB, Siemens and Schneider Electric covers everything between the supply and the motor shaft. The range spans contactors, overload relays, motor protection circuit breakers, starters, soft starters, variable frequency drives, servo systems and industrial motors, with rated currents from 0.1 A to 2,650 A and power up to 800 kW. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Contactors – switching devices for motor and load circuits, mostly 3-pole
- Thermal Overload Relays – bimetal and electronic relays for motor overload protection
- Motor Protection Circuit Breakers (MPCB) – short-circuit and overload protection in one device
- Motor Starters & Motor Management – starter combinations and motor controllers such as TeSys U and SIRIUS 3RK
- Soft Starters – controlled ramp-up for 3-phase motors
- Variable Frequency Drives (VFD) – speed control with ABB ACS, Schneider Altivar and Siemens SINAMICS
- Servo Drives & Motion Control – servo motors, drives, controllers and cables
- Industrial Motors – SIMOTICS asynchronous motors
How to choose
- Motor power and rated current at the supply voltage. Size the starter or drive for the nameplate current, not just the kW value.
- Starting method: direct on line, soft start or variable speed. This decides whether you need a contactor, a soft starter or a VFD.
- Duty class, for example AC-3 for squirrel-cage motors under IEC 60947-4-1.
- Protection split: overload relay plus fuses or MCB, or a single MPCB.
- Control interface: coil voltage, fieldbus such as PROFINET, and mounting.
FAQ
What is the difference between a soft starter and a VFD?
A soft starter limits inrush current during start and stop at fixed supply frequency. A VFD changes the output frequency, so it also controls speed while running.
Do I need a contactor and an overload relay, or an MPCB?
An MPCB combines short-circuit and overload protection and works with a contactor. The separate route uses a fuse or MCB, a contactor and an overload relay. Choose by space, coordination type and rating.
Can you ship motor control products outside Turkey?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.