Schneider Electric LUA1C11 TeSys U Auxiliary Signalling Contacts 1 NO + 1 NC Auxiliary Contact Block
Schneider Electric LUA1C20 TeSys U Auxiliary Signalling Contacts 2 NO Auxiliary Contact Block
Schneider Electric LA9LB920 TeSys Current Limiter Module 32 A 690 V AC Contactor Accessory
Schneider Electric VZN11 TeSys Mini-VARIO Additional Neutral Block 1N 20 A for VN12/VN20 Contactor Accessory
Schneider Electric VZN05 TeSys Mini-VARIO Auxiliary Contact Block 1NO Late-Make for Contactor Accessory
Schneider Electric VZN06 TeSys Mini-VARIO Auxiliary Contact 1NC Early-Break for VN12/VN20 Contactor Accessory
Schneider Electric VZN17 TeSys VARIO Shaft Extension for VN12/VN20/V02-V2 Contactor Accessory
Schneider Electric LX1G3RKUEN TeSys Giga Control Module 3P 100-250 V AC/DC for LC1G265...330 Contactor Coil
Schneider Electric LX1G3RLSEA TeSys Giga Control Module 3P 200-500 V AC/DC for LC1G265...330 Contactor Coil
Schneider Electric VZ13 TeSys VARIO Additional Neutral Block 1N 175 A for V5/V6 Contactor Accessory
Schneider Electric VZ14 TeSys VARIO Additional Earthing Block 40 A for V02-V2 Contactor Accessory
Schneider Electric LX1G3SEHEN TeSys Giga Control Module 3P 48-130 V AC/DC for LC1G400...500 Contactor Coil
Schneider Electric VZ16 TeSys VARIO Additional Earthing Block 175 A for V5/V6 Contactor Accessory
Schneider Electric LX1G3SKUEN TeSys Giga Control Module 3P 100-250 V AC/DC for LC1G400...500 Contactor Coil
Schneider Electric LX1G3SLSEA TeSys Giga Control Module 3P 200-500 V AC/DC for LC1G400...500 Contactor Coil
Schneider Electric LX1G3TKUEN TeSys Giga Control Module 3P 100-250 V AC/DC for LC1G630...800 Contactor Coil
Schneider Electric LXD1V7 TeSys Deca Contactor Coil 400 V AC 50/60 Hz for LC1D09-D38 Contactor Coil
Schneider Electric LXD3V7 TeSys Deca Contactor Coil 400 V AC 50/60 Hz for LC1D40A-D65A Contactor Coil
Schneider Electric VZ10 TeSys Vario Terminal Shroud 3P for V5-V6 Contactor Accessory
Schneider Electric VZ15 TeSys Vario Additional Earthing Block 80 A for V3-V4 Contactor Accessory
Contactors from ABB, Schneider Electric and Siemens switch motor and load circuits on and off by remote control. This range covers over 900 products, from 2 A accessories to power contactors rated up to 2650 A, with motor ratings from 2.2 kW to 450 kW in 2, 3, 4 and 8 pole versions. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Power Contactors (AC-3) – the main motor-switching contactors, including ABB AF, TeSys Deca, TeSys Giga, TeSys K, Easy TeSys and SIRIUS 3RT2 and 3RT1.
- Contactor Relays & Auxiliary Contactors – control-circuit relays with several auxiliary contacts.
- Installation Contactors – DIN-rail contactors for distribution boards, such as ABB ESB.
- Contactor Accessories (Coils, Aux Blocks) – replacement coils, auxiliary contact blocks and mounting parts.
How to choose
- Utilization category: AC-3 for squirrel-cage motor starting, AC-1 for resistive loads. The same frame carries a different current in each category.
- Rated current and motor power at your operating voltage, with margin for the duty cycle.
- Number of poles: 3P for three-phase motors, 4P for switching the neutral or four-wire loads.
- Coil voltage and type (AC, DC or AC/DC). It must match the control supply.
- Auxiliary contacts: count the NO and NC contacts the control circuit needs, and check if the contactor accepts add-on blocks.
FAQ
What is the difference between a contactor and a contactor relay?
A power contactor switches the main circuit of a motor or load. A contactor relay switches control circuits at low current, typically 10 A, and has more auxiliary contacts.
Which standard applies to contactors?
Low-voltage contactors are covered by IEC 60947-4-1. The standard defines utilization categories such as AC-1 and AC-3.
Do you ship contactors outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.