- Home
- All Collections
- Switch Disconnectors & Transfer Switches
Switch Disconnectors & Transfer Switches
Switch Disconnectors & Transfer Switches Categories
Switch Disconnectors & Transfer Switches
Schneider Electric VCF0 VCF TeSys VARIO 3P 25A 690V 5.5kW Emergency Stop Switch Disconnector
Schneider Electric VCDN20 TeSys Mini-VARIO Emergency Stop 3P 20 A 690 V AC Switch Disconnector
Schneider Electric VCDN12 TeSys Mini-VARIO Emergency Stop 3P 12 A 690 V AC Switch Disconnector
Schneider Electric VBF6 TeSys VARIO Switch Disconnector 3P 175 A 690 V AC Switch Disconnector
Schneider Electric VBF5 TeSys VARIO Switch Disconnector 3P 125 A 690 V AC Switch Disconnector
Schneider Electric VBF4 TeSys VARIO Switch Disconnector 3P 80 A 690 V AC Switch Disconnector
Schneider Electric VBF3 TeSys VARIO Switch Disconnector 3P 63 A 690 V AC Switch Disconnector
Schneider Electric VBF2 TeSys VARIO Switch Disconnector 3P 40 A 690 V AC Switch Disconnector
Schneider Electric VBF1 TeSys Control 32A Door Mount Switch Disconnector 4-Screw Fixing
Schneider Electric VBF02 TeSys VARIO Switch Disconnector 3P 12 A 690 V AC Switch Disconnector
Schneider Electric VBF01 TeSys Control 4-Screw Door Mounting Switch Disconnector 0.351kg
Schneider Electric VBF0 TeSys VARIO Switch Disconnector 3P 25 A 690 V AC Switch Disconnector
Schneider Electric VBDN20 TeSys Mini-VARIO Switch Disconnector 3P 20 A 690 V AC Switch Disconnector
Schneider Electric VBDN12 TeSys Mini-VARIO Switch Disconnector 3P 12 A 690 V AC Switch Disconnector
ABB 1SCA117038R1001 OMZC04 Parallel Connection Kit Accessory for Low-Voltage Switch Technology
ABB 1SCA101659R1001 OXS6X180 6×6×180mm Switch Operating Shaft
ABB 1SCA022381R0830 OHB95J12 Pistol Handle for Enclosed Switches & Motor Controllers
ABB 1SCA022380R9660 OHB65J6 Pistol Handle for Switch-Disconnectors IP65 DIN-Rail Mount
ABB 2CCA703031R0001 E214-25-202 25A 250V AC 2P DIN Rail Group Switch
ABB 1SBN081018R2000 BEY16C-3 Connection Set for Star-Delta Starter Low-Voltage Switch Technology Accessory
Switch disconnectors and transfer switches from ABB, Siemens, Schneider Electric and Mersen, covering isolation, manual changeover, automatic transfer and cam switching from 6 A up to 3800 A. The range includes 1P to 4P devices, with 3P and 4P the most common. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Switch Disconnectors – load-break isolators for panels and machines, including handles, shafts and interlocks.
- Changeover Switches (Manual & Motorized) – select between two supplies, such as mains and generator.
- Automatic Transfer Switches (ATS) – controller-driven transfer, including TransferPacT and ABB OXB and OTM units.
- Cam Switches – Harmony K rotary switches for control, metering and small loads.
How to choose
- Rated current and utilization category. Match the AC-22 or AC-23 duty to the load, and size for the full load current.
- Pole count. Use 4P where the neutral must be switched, for example when changing between two sources.
- Voltage and short-circuit withstand. Check the rating against the fault level at the installation point.
- Control method. Manual operation suits most panels. Choose motorized or automatic transfer when the change must happen without an operator.
- Mounting. Pick DIN-rail, base, door-coupled or enclosed to fit the panel layout.
FAQ
What is the difference between a switch disconnector and a circuit breaker?
A switch disconnector isolates and switches load current but gives no overcurrent protection. A circuit breaker also trips on overload and short circuit, so a protective device is normally installed upstream of the switch.
When should I use an ATS instead of a manual changeover switch?
Use an ATS when the transfer must happen automatically after a mains failure, for example to a generator. A manual changeover switch needs an operator and suits sites where short outages are acceptable.
Do you ship outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and we quote project quantities on request.