The Schneider Electric VCDN20 is a 3-pole TeSys Mini-VARIO switch-disconnector rated 20 A, built from a VZ20 switch body with a padlockable red handle on a yellow front plate for emergency-stop switching up to 5.5 kW at 400 V AC-23. It mounts through a single 22.5 mm door hole and carries IP65 protection once installed.
Technical Specifications
| SKU | VCDN20 |
| Brand | Schneider Electric |
| Range | TeSys Mini-VARIO |
| Device Short Name | VCDN |
| Switch Body | VZ20 |
| Poles | 3P |
| Contacts | 3 NO |
| Rated Operational Voltage (Ue) | 690 V AC 50/60 Hz |
| Rated Operational Current (Ie, AC-23, 400 V) | 11 A |
| Conventional Free Air Thermal Current (Ith) | 20 A |
| Conventional Enclosed Thermal Current (Ithe) | 16 A |
| Rated Operational Power (AC-23A, 400 V) | 5.5 kW |
| Rated Operational Power (AC-3, 400 V) | 3 kW |
| Making Capacity (AC-21/22/23A, 400 V) | 200 A |
| Breaking Capacity (AC-21/22/23A, 400 V) | 200 A |
| Rated Conditional Short-Circuit Current | 6 kA (20 A aM/gG fuse) |
| Short-Circuit Making Capacity (Icm) | 0.5 kA |
| Short-Time Withstand Current (Icw, 1 s) | 140 A (1 s) |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV |
| Handle Colour / Front Plate | Red / Yellow |
| Mounting | Handle door or switch door, hole 22.5 mm |
| IP Degree of Protection | IP65 (mounted) |
| Ambient Temperature (Operation) | -20 to 50 degC |
Certifications & Standards
- GL
- CSA
- UL
- CCC
- UKCA
- IEC 60947-3
Selection Notes
The VCDN20 uses the same VZ20 switch body and current rating as the VBDN20, but the red-on-yellow handle marks it for emergency-stop duty per IEC 60204-1 colour coding. Choose it over the VCDN12 once the motor exceeds 4 kW at 400 V. Up to two add-on poles can be fitted either side of the body — main (VZN12), neutral (VZN11), earthing (VZN14) or auxiliary contacts (VZN05, VZN06).
Data note: the breaking capacity row is published on se.com as 200 A at 400 V; this is carried through verbatim, though it is inconsistent with the 0.5 kA Icm rating for the same device, suggesting a possible source unit typo (A vs kA).