- Home
- All Collections
- Switch Disconnectors & Transfer Switches
Switch Disconnectors & Transfer Switches
Switch Disconnectors & Transfer Switches Categories
Switch Disconnectors & Transfer Switches
Schneider Electric K2B002ALH Harmony K K2 2-Pole 20A 45deg Cam Switch
Schneider Electric K1D024MLH Harmony K K1 3-Phase 12A Cam Voltmeter Switch
Schneider Electric K1D004QLH Harmony K K1 12A 1P 4-Step Cam Stepping Switch
Schneider Electric K1D002ULH Harmony K K1 12A 2P 45° Cam Changeover Switch
Schneider Electric K1C003QLH Harmony K K1 12A 1P 3-Step Cam Stepping Switch
Schneider Electric K1C003NLH Harmony K K1 1-Pole 12A 3-Step Cam Stepping Switch
Schneider Electric K1C003ALH Harmony K K1 3-Pole 12A 45deg Cam Switch
Schneider Electric K1B002QLH Harmony K K1 1-Pole 12A 45deg Cam Stepping Switch
Schneider Electric K1B002ALH Harmony K K1 2-Pole Cam Switch 12 A 45 Degree
Schneider Electric K1B001ULH Harmony K K1 1-Pole Changeover Cam Switch 12 A 45 Degree
Schneider Electric VCFN20GE TeSys Mini-VARIO Enclosed 3P 16 A 690 V AC IP55 Switch Disconnector
Schneider Electric VCFN12GE TeSys Mini-VARIO Enclosed 3P 10 A 690 V AC IP55 Switch Disconnector
Schneider Electric VCF6 TeSys Control 175A Door Mount Switch Disconnector
Schneider Electric VCF5 TeSys 3P 125A Door Mount Switch Disconnector
Schneider Electric VCF4 VCFN 3P 80A TeSys Control Switch Disconnector Door Mount
Schneider Electric VCF3 TeSys Control 63A Door Mount Switch Disconnector 4-Screw Fixing
Schneider Electric VCF2 VCF 3-Pole 40A Door Mount Switch Disconnector TeSys Control
Schneider Electric VCF1 VCF 3P 32A TeSys Control Switch Disconnector Door Mount
Schneider Electric VCF02 TeSys Control Switch Disconnector 4-Screw Door Mount
Schneider Electric VCF01 TeSys Control Door Mount Switch Disconnector 4-Screw Fixing
Switch disconnectors and transfer switches from ABB, Siemens, Schneider Electric and Mersen, covering isolation, manual changeover, automatic transfer and cam switching from 6 A up to 3800 A. The range includes 1P to 4P devices, with 3P and 4P the most common. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Switch Disconnectors – load-break isolators for panels and machines, including handles, shafts and interlocks.
- Changeover Switches (Manual & Motorized) – select between two supplies, such as mains and generator.
- Automatic Transfer Switches (ATS) – controller-driven transfer, including TransferPacT and ABB OXB and OTM units.
- Cam Switches – Harmony K rotary switches for control, metering and small loads.
How to choose
- Rated current and utilization category. Match the AC-22 or AC-23 duty to the load, and size for the full load current.
- Pole count. Use 4P where the neutral must be switched, for example when changing between two sources.
- Voltage and short-circuit withstand. Check the rating against the fault level at the installation point.
- Control method. Manual operation suits most panels. Choose motorized or automatic transfer when the change must happen without an operator.
- Mounting. Pick DIN-rail, base, door-coupled or enclosed to fit the panel layout.
FAQ
What is the difference between a switch disconnector and a circuit breaker?
A switch disconnector isolates and switches load current but gives no overcurrent protection. A circuit breaker also trips on overload and short circuit, so a protective device is normally installed upstream of the switch.
When should I use an ATS instead of a manual changeover switch?
Use an ATS when the transfer must happen automatically after a mains failure, for example to a generator. A manual changeover switch needs an operator and suits sites where short outages are acceptable.
Do you ship outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and we quote project quantities on request.