Filter

Switch Disconnectors & Transfer Switches Categories

Switch Disconnectors & Transfer Switches

Filter
Showing 1 - 420 of 552 items

Schneider Electric K2B002ALH Harmony K K2 2-Pole 20A 45deg Cam Switch

Reference No: K2B002ALH
Number of Poles: 2P
0 pcs in stock
$22.46

Schneider Electric K1D024MLH Harmony K K1 3-Phase 12A Cam Voltmeter Switch

Reference No: K1D024MLH
Number of Poles: 1P
0 pcs in stock
$30.61

Schneider Electric K1D004QLH Harmony K K1 12A 1P 4-Step Cam Stepping Switch

Reference No: K1D004QLH
Number of Poles: 2P
0 pcs in stock
$30.61

Schneider Electric K1D002ULH Harmony K K1 12A 2P 45° Cam Changeover Switch

Reference No: K1D002ULH
Number of Poles: 1P
0 pcs in stock
$29.04

Schneider Electric K1C003QLH Harmony K K1 12A 1P 3-Step Cam Stepping Switch

Reference No: K1C003QLH
Number of Poles: 1P
0 pcs in stock
$25.93

Schneider Electric K1C003NLH Harmony K K1 1-Pole 12A 3-Step Cam Stepping Switch

Reference No: K1C003NLH
Number of Poles: 2P
0 pcs in stock
$25.93

Schneider Electric K1C003ALH Harmony K K1 3-Pole 12A 45deg Cam Switch

Reference No: K1C003ALH
0 pcs in stock
$24.16

Schneider Electric K1B002QLH Harmony K K1 1-Pole 12A 45deg Cam Stepping Switch

Reference No: K1B002QLH
Number of Poles: 1P
0 pcs in stock
$21.69

Schneider Electric K1B002ALH Harmony K K1 2-Pole Cam Switch 12 A 45 Degree

Reference No: K1B002ALH
Number of Poles: 2P
0 pcs in stock
$21.38

Schneider Electric K1B001ULH Harmony K K1 1-Pole Changeover Cam Switch 12 A 45 Degree

Reference No: K1B001ULH
Number of Poles: 1P
0 pcs in stock
$21.38

Schneider Electric VCFN20GE TeSys Mini-VARIO Enclosed 3P 16 A 690 V AC IP55 Switch Disconnector

Reference No: VCFN20GE
Catalog No: VCFN20GE
Rated Current (A): 16
Rated Voltage (VAC): 690 V AC
Number of Poles: 1P+N
0 pcs in stock
$36.25

Schneider Electric VCFN12GE TeSys Mini-VARIO Enclosed 3P 10 A 690 V AC IP55 Switch Disconnector

Reference No: VCFN12GE
Catalog No: VCFN12GE
Rated Current (A): 10
Rated Voltage (VAC): 690 V AC
Number of Poles: 1P
0 pcs in stock
$31.63

Schneider Electric VCF6 TeSys Control 175A Door Mount Switch Disconnector

Reference No: VCF6
Rated Current (A): 175
82 pcs in stock
$180.21

Schneider Electric VCF5 TeSys 3P 125A Door Mount Switch Disconnector

Reference No: VCF5
Rated Current (A): 125
Number of Poles: 3P
84 pcs in stock
$135.77

Schneider Electric VCF4 VCFN 3P 80A TeSys Control Switch Disconnector Door Mount

Reference No: VCF4
Rated Current (A): 80
Number of Poles: 3P
100 pcs in stock
$88.03

Schneider Electric VCF3 TeSys Control 63A Door Mount Switch Disconnector 4-Screw Fixing

Reference No: VCF3
Rated Current (A): 63
100 pcs in stock
$67.49

Schneider Electric VCF2 VCF 3-Pole 40A Door Mount Switch Disconnector TeSys Control

Reference No: VCF2
Rated Current (A): 40
Number of Poles: 3P
100 pcs in stock
$56.20

Schneider Electric VCF1 VCF 3P 32A TeSys Control Switch Disconnector Door Mount

Reference No: VCF1
Rated Current (A): 32
Number of Poles: 3P
100 pcs in stock
$42.80

Schneider Electric VCF02 TeSys Control Switch Disconnector 4-Screw Door Mount

Reference No: VCF02
59 pcs in stock
$30.96

Schneider Electric VCF01 TeSys Control Door Mount Switch Disconnector 4-Screw Fixing

Reference No: VCF01
100 pcs in stock
$32.21

Switch disconnectors and transfer switches from ABB, Siemens, Schneider Electric and Mersen, covering isolation, manual changeover, automatic transfer and cam switching from 6 A up to 3800 A. The range includes 1P to 4P devices, with 3P and 4P the most common. Stoklink ships worldwide from Turkey and quotes project volumes on request.

What's in this range

How to choose

  • Rated current and utilization category. Match the AC-22 or AC-23 duty to the load, and size for the full load current.
  • Pole count. Use 4P where the neutral must be switched, for example when changing between two sources.
  • Voltage and short-circuit withstand. Check the rating against the fault level at the installation point.
  • Control method. Manual operation suits most panels. Choose motorized or automatic transfer when the change must happen without an operator.
  • Mounting. Pick DIN-rail, base, door-coupled or enclosed to fit the panel layout.

FAQ

What is the difference between a switch disconnector and a circuit breaker?

A switch disconnector isolates and switches load current but gives no overcurrent protection. A circuit breaker also trips on overload and short circuit, so a protective device is normally installed upstream of the switch.

When should I use an ATS instead of a manual changeover switch?

Use an ATS when the transfer must happen automatically after a mains failure, for example to a generator. A manual changeover switch needs an operator and suits sites where short outages are acceptable.

Do you ship outside Turkey?

Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and we quote project quantities on request.