Filter

Switch Disconnectors & Transfer Switches Categories

Switch Disconnectors & Transfer Switches

Filter
Showing 1 - 400 of 552 items

Siemens 3KD3630-0PE10-0 3KD3 200A 3P 10V Switch Disconnector

Reference No: 3KD3630-0PE10-0
Catalog No: 3KD3630-0PE10-0
Rated Current (A): 200
Rated Voltage (VAC): 10 V
Number of Poles: 3P
4 pcs in stock
$234.81

Siemens 3KD3630-0NE20-0 3KD3 200A 3P 10V Switch Disconnector

Reference No: 3KD3630-0NE20-0
Catalog No: 3KD3630-0NE20-0
Rated Current (A): 200
Rated Voltage (VAC): 10 V
Number of Poles: 3P
0 pcs in stock
$235.76

Siemens 3KD3630-0NE10-0 3KD3 200A 3P 10V Switch Disconnector

Reference No: 3KD3630-0NE10-0
Catalog No: 3KD3630-0NE10-0
Rated Current (A): 200
Rated Voltage (VAC): 10 V
Number of Poles: 3P
0 pcs in stock
$192.90

Siemens 3KD3430-0NE20-0 3KD3 160A 3P 10V Switch Disconnector

Reference No: 3KD3430-0NE20-0
Catalog No: 3KD3430-0NE20-0
Rated Current (A): 160
Rated Voltage (VAC): 10 V
Number of Poles: 3P
0 pcs in stock
$208.55

Siemens 3KD3430-0NE10-0 3KD3 160A 3P 10V Switch Disconnector

Reference No: 3KD3430-0NE10-0
Catalog No: 3KD3430-0NE10-0
Rated Current (A): 160
Rated Voltage (VAC): 10 V
Number of Poles: 3P
3 pcs in stock
$170.64

Siemens 3KD3230-0NE20-0 3KD3 125A 3P 10V Switch Disconnector

Reference No: 3KD3230-0NE20-0
Catalog No: 3KD3230-0NE20-0
Rated Current (A): 125
Rated Voltage (VAC): 10 V
Number of Poles: 3P
0 pcs in stock
$179.72

Siemens 3KD3230-0NE10-0 3KD3 125A 3P 10V Switch Disconnector

Reference No: 3KD3230-0NE10-0
Catalog No: 3KD3230-0NE10-0
Rated Current (A): 125
Rated Voltage (VAC): 10 V
Number of Poles: 3P
0 pcs in stock
$179.72

Siemens 3KD3030-0NE20-0 3KD3 100A 3P 10V Switch Disconnector

Reference No: 3KD3030-0NE20-0
Catalog No: 3KD3030-0NE20-0
Rated Current (A): 100
Rated Voltage (VAC): 10 V
Number of Poles: 3P
0 pcs in stock
$150.82

Siemens 3KD3030-0NE10-0 3KD3 100A 3P 10V Switch Disconnector

Reference No: 3KD3030-0NE10-0
Catalog No: 3KD3030-0NE10-0
Rated Current (A): 100
Rated Voltage (VAC): 10 V
Number of Poles: 3P
0 pcs in stock
$123.41

Siemens 3KD2830-0NE20-0 3KD2 80A 3P 10V Switch Disconnector

Reference No: 3KD2830-0NE20-0
Catalog No: 3KD2830-0NE20-0
Rated Current (A): 80
Rated Voltage (VAC): 10 V
Number of Poles: 3P
0 pcs in stock
$108.38

Siemens 3KD2830-0NE10-0 3KD2 80A 3P 10V Switch Disconnector

Reference No: 3KD2830-0NE10-0
Catalog No: 3KD2830-0NE10-0
Rated Current (A): 80
Rated Voltage (VAC): 10 V
Number of Poles: 3P
11 pcs in stock
$108.38

Siemens 3KD4630-0QE20-0 SENTRON 3KD 630A 3P 690V Center-Drive Switch Disconnector

Reference No: 3KD4630-0QE20-0
Catalog No: 3KD4630-0QE20-0
Rated Current (A): 630
Rated Voltage (VAC): 690 V
Number of Poles: 3P
10 pcs in stock
$765.60

Schneider Electric K63F003UP Harmony K K63 63A 3P 60° Cam Changeover Switch

Reference No: K63F003UP
0 pcs in stock
$233.39

Schneider Electric K50F003UP Harmony K K50 3-Pole 50A Cam Changeover Switch

Reference No: K50F003UP
Number of Poles: 3P
0 pcs in stock
$204.93

Schneider Electric K30F003UP Harmony K K30 3-Pole 32A Front Mount Cam Switch

Reference No: K30F003UP
Number of Poles: 2P
0 pcs in stock
$138.52

Schneider Electric K30D002UP Harmony K K30 2-Pole 32A Front Mount Cam Switch

Reference No: K30D002UP
Number of Poles: 2P
0 pcs in stock
$108.79

Schneider Electric K2H004ULH Harmony K K2 20A 4P 45° Cam Changeover Switch

Reference No: K2H004ULH
Number of Poles: 3P
0 pcs in stock
$46.49

Schneider Electric K2F003ULH Harmony K K2 20A 3P 45° Cam Changeover Switch

Reference No: K2F003ULH
Number of Poles: 4P
0 pcs in stock
$39.85

Schneider Electric K2D002ULH Harmony K K2 20A 2P 45° Cam Changeover Switch

Reference No: K2D002ULH
0 pcs in stock
$31.69

Schneider Electric K2C003ALH Harmony K K2 3-Pole 20A 45deg Cam Switch

Reference No: K2C003ALH
0 pcs in stock
$25.93

Switch disconnectors and transfer switches from ABB, Siemens, Schneider Electric and Mersen, covering isolation, manual changeover, automatic transfer and cam switching from 6 A up to 3800 A. The range includes 1P to 4P devices, with 3P and 4P the most common. Stoklink ships worldwide from Turkey and quotes project volumes on request.

What's in this range

How to choose

  • Rated current and utilization category. Match the AC-22 or AC-23 duty to the load, and size for the full load current.
  • Pole count. Use 4P where the neutral must be switched, for example when changing between two sources.
  • Voltage and short-circuit withstand. Check the rating against the fault level at the installation point.
  • Control method. Manual operation suits most panels. Choose motorized or automatic transfer when the change must happen without an operator.
  • Mounting. Pick DIN-rail, base, door-coupled or enclosed to fit the panel layout.

FAQ

What is the difference between a switch disconnector and a circuit breaker?

A switch disconnector isolates and switches load current but gives no overcurrent protection. A circuit breaker also trips on overload and short circuit, so a protective device is normally installed upstream of the switch.

When should I use an ATS instead of a manual changeover switch?

Use an ATS when the transfer must happen automatically after a mains failure, for example to a generator. A manual changeover switch needs an operator and suits sites where short outages are acceptable.

Do you ship outside Turkey?

Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and we quote project quantities on request.