- Home
- All Collections
- Switch Disconnectors & Transfer Switches
Switch Disconnectors & Transfer Switches
Switch Disconnectors & Transfer Switches Categories
Switch Disconnectors & Transfer Switches
ABB 1SBN031005T1000 VM3 Mechanical Interlock Unit Mechanic Interlock for Switch
ABB 1SBN050010R1000 RV5/50 24-50V AC/DC Clip-On Surge Suppressor Accessory for Low-Voltage Switch Technology
ABB 1SDA054922R1 ADP 6pin AUX T4-T5-T6 P/W Auxiliary Adapter Accessory for SACE Tmax T4 T5 T6 Circuit Breakers
ABB 1SDA105123R1 MIR-P x XT5 P/W 400A FP Mechanic Interlock for Switch Tmax XT5 200x250x10mm
ABB 1SDA105124R1 MIR-P x XT5 P/W 630A FP Mechanic Interlock for Switch Tmax XT
ABB 1SDA066180R1 KIT DIN50022 A1-A2 PLATE DIN FORMULA Series DIN Rail Mounting Plate Accessory for Low-Voltage Circuit Breakers
ABB 1SCA022325R6980 OXP12X250 12x12x250mm 0.275kg Switch Operating Shaft
ABB 2CDS200918R0001 S2C-NT Hand Operated Neutral Accessory for S200 Series Low-Voltage Circuit Breakers
ABB 2CCG000242R0001 SCU100 InSite Pro M Compact Accessory for Low-Voltage Switch Technology
ABB 1SDA065524R1 ATS022 AUTO.TRAN.SWITCH ADVANCED CONTROL Automatic Transfer Switch
ABB 1SDA065523R1 ATS021 Automatic Transfer Switch Mutli Voltage Automatic Transfer Switch
ABB 1SDA073906R1 Terminals term.box E1.2..E6.2-XT7/M 10pz SACE Emax 2 Terminal Box Accessory for Low-Voltage Circuit Breakers
Switch disconnectors and transfer switches from ABB, Siemens, Schneider Electric and Mersen, covering isolation, manual changeover, automatic transfer and cam switching from 6 A up to 3800 A. The range includes 1P to 4P devices, with 3P and 4P the most common. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Switch Disconnectors – load-break isolators for panels and machines, including handles, shafts and interlocks.
- Changeover Switches (Manual & Motorized) – select between two supplies, such as mains and generator.
- Automatic Transfer Switches (ATS) – controller-driven transfer, including TransferPacT and ABB OXB and OTM units.
- Cam Switches – Harmony K rotary switches for control, metering and small loads.
How to choose
- Rated current and utilization category. Match the AC-22 or AC-23 duty to the load, and size for the full load current.
- Pole count. Use 4P where the neutral must be switched, for example when changing between two sources.
- Voltage and short-circuit withstand. Check the rating against the fault level at the installation point.
- Control method. Manual operation suits most panels. Choose motorized or automatic transfer when the change must happen without an operator.
- Mounting. Pick DIN-rail, base, door-coupled or enclosed to fit the panel layout.
FAQ
What is the difference between a switch disconnector and a circuit breaker?
A switch disconnector isolates and switches load current but gives no overcurrent protection. A circuit breaker also trips on overload and short circuit, so a protective device is normally installed upstream of the switch.
When should I use an ATS instead of a manual changeover switch?
Use an ATS when the transfer must happen automatically after a mains failure, for example to a generator. A manual changeover switch needs an operator and suits sites where short outages are acceptable.
Do you ship outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and we quote project quantities on request.