- Home
- All Collections
- Power Contactors (AC-3)
Power Contactors (AC-3)
Schneider Electric LC1DT200A6KUE TeSys Deca Advanced 4P 4NO AC-1 200 A 100-250 V AC/DC Coil Contactor
Schneider Electric LC1DT32F7 TeSys Deca Contactor 4P 4NO AC-1 32 A 110 V AC Coil Contactor
Schneider Electric LC1DT200A6EHE TeSys Deca Advanced Contactor 4P 4NO AC-1 200 A 48-130 V AC/DC Coil Contactor
Schneider Electric LC1DT25FD TeSys Deca Contactor 4P 4NO AC-1 25 A 110 V DC Coil Contactor
Schneider Electric LC1D80AKUE TeSys Deca Advanced Contactor 3P 3NO AC-3 66 A 100-250 V AC/DC Coil Contactor
Schneider Electric LC1DT25ED TeSys Deca Contactor 4P 4NO AC-1 25 A 48 V DC Coil Contactor
Schneider Electric LC1D65AKUE TeSys Deca Advanced Contactor 3P 3NO AC-3 65 A 100-250 V AC/DC Coil Contactor
Schneider Electric LC1DT25B7 TeSys Deca Contactor 4P 4NO AC-1 25 A 24 V AC Coil Contactor
Schneider Electric LC1D65ABNE TeSys Deca Advanced Contactor 3P 3NO AC-3 65 A 24-60 V AC/DC Coil Contactor
Schneider Electric LC1DT20FD TeSys Deca Contactor 4P 4NO AC-1 20 A 110 V DC Coil Contactor
Schneider Electric LC1D50AKUE TeSys Deca Advanced Contactor 3P 3NO AC-3 50 A 100-250 V AC/DC Coil Contactor
Schneider Electric LC1D95V7 TeSys Deca Contactor 3P 3NO AC-3 95 A 400 V AC Coil Contactor
Schneider Electric LC1D50AEHE TeSys Deca Advanced Contactor 3P 3NO AC-3 50 A 48-130 V AC/DC Coil Contactor
Schneider Electric LC1D95Q7 TeSys Deca Contactor 3P 3NO AC-3 95 A 380 V AC Coil Contactor
Schneider Electric LC1D50ABNE TeSys Deca Advanced Contactor 3P 3NO AC-3 50 A 24-60 V AC/DC Coil Contactor
Schneider Electric LC1D95ED TeSys Deca Contactor 3P 3NO AC-3 95 A 48 V DC Coil Contactor
Schneider Electric LC1D40AKUE TeSys Deca Advanced Contactor 3P 3NO AC-3 40 A 100-250 V AC/DC Coil Contactor
Schneider Electric LC1D95D7 TeSys Deca Contactor 3P 3NO AC-3 95 A 42 V AC Coil Contactor
Schneider Electric LC1D40AEHE TeSys Deca Advanced Contactor 3P 3NO AC-3 40 A 48-130 V AC/DC Coil Contactor
Schneider Electric LC1D80V7 TeSys Deca Contactor 3P 3NO AC-3 80 A 400 V AC Coil Contactor
Power contactors (AC-3) from ABB, Schneider Electric and Siemens start and stop three-phase motors and switch heavy loads. The range covers over 650 products from 6 A to 2650 A, with motor ratings from 2.2 kW to 450 kW, mostly in 3 and 4 pole versions. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- ABB AF Contactors – 3 and 4 pole AF series with wide-range AC/DC coils.
- Schneider TeSys Deca Contactors – the largest series here, from 9 A to 200 A.
- Schneider TeSys Giga Contactors – high-current frames from 115 A to 800 A.
- Schneider TeSys K Contactors – compact contactors for 6 A to 16 A.
- Schneider Easy TeSys Contactors – general-purpose contactors from 6 A to 630 A.
- Siemens SIRIUS 3RT2 Contactors and Siemens SIRIUS 3RT1 Contactors – SIRIUS frames from small to very large.
How to choose
- Motor power and current in AC-3 at your supply voltage. Do not size from the AC-1 value.
- Pole count: 3P for motors, 4P where the neutral is switched.
- Coil voltage and type, AC or DC, against the control supply.
- Short-circuit protection and overload relay matched to the contactor, following the manufacturer's coordination tables.
- Auxiliary contact needs and whether add-on blocks fit the frame.
FAQ
What does AC-3 mean on a contactor?
AC-3 is the IEC 60947-4-1 category for starting and stopping squirrel-cage motors. Ratings in AC-3 are usually lower than AC-1 for the same frame.
Can I replace a contactor with another brand?
Check rated current in AC-3, pole count, coil voltage and mounting dimensions. Auxiliary contacts and coordination with the overload relay must also match.
Do you ship contactors outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.