Contactors for Data Center PDU and UPS Systems: Selection Guide
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
Schneider Electric TeSys Giga 4P contactor, 550 A AC-1 at ≤440 V, 48-130 V AC/DC coil, plate mount, Contact Wear Diagnosis.
The Schneider Electric LC1G4004EHEN is a 4-pole TeSys Giga high-power contactor rated 550 A AC-1 at up to 440 V, built for heavy power-switching duty rather than motor AC-3 starting. It runs on a 48-130 V AC/DC wide-band electronic coil with built-in peak limiting, ships with a 1 NO + 1 NC auxiliary contact block and local Contact Wear Diagnosis, and mounts on a plate 185 mm wide.
The 4P/4NO contact arrangement with AC-1-only duty targets heavy resistive or power-distribution switching rather than three-phase motor starting; for motor AC-3 duty at a comparable frame size, pick the corresponding 3-pole Giga variant instead. Local Contact Wear Diagnosis flags power-contact wear before failure, and the switching module can be replaced in place without removing busbars. The 48-130 V AC/DC coil spans the whole band without a separate coil code per voltage, which simplifies sourcing across regions.
| Range | TeSys |
|---|---|
| Range of Product | TeSys Giga |
| Product or Component Type | Contactor |
| Device short name | LC1G |
| Contactor application | Power switching |
| Utilisation category | AC-3 AC-3e AC-1 AC-5a AC-5b AC-6a AC-6b DC-1 DC-3 DC-5 |
| Poles description | 4P |
| [Ue] rated operational voltage | <= 1000 V AC 50/60 Hz <= 460 V DC |
| [Ie] rated operational current | 400 A (at <140 °F (60 °C)) at <= 440 V AC-3 550 A (at <104 °F (40 °C)) at <= 1000 V AC-1 |
| [Uc] control circuit voltage | 48...130 V AC 50/60 Hz 48...130 V DC |
| Control circuit voltage limits | Operational: 0.8 Uc Min...1.1 Uc Max (at <140 °F (60 °C)) Drop-out: 0.1 Uc Max...0.45 Uc Min (at <140 °F (60 °C)) |
| [Uimp] rated impulse withstand voltage | 8 kV |
|---|---|
| Overvoltage category | III |
| [Ith] conventional free air thermal current | 550 A (at 104 °F (40 °C)) |
| Rated breaking capacity | 3480 A at 440 V |
| [Icw] rated short-time withstand current | 3.6 kA - 10 s 2.4 kA - 30 s 1.7 kA - 1 min 1.2 kA - 3 min 1.0 kA - 10 min |
| Associated fuse rating | 500 A aM at <= 440 V for motor 315 A aM at <= 690 V for motor 630 A gG at <= 690 V 600 A UL Type L at <= 600 V |
| Average impedance | 0.0001 Ohm |
| [Ui] rated insulation voltage | 1000 V |
| Power dissipation per pole | 30 W AC-1 - Ith 550 A 16 W AC-3 - Ith 400 A |
| Compatibility code | LC1G |
| Pole contact composition | 4 NO |
| Auxiliary contact composition | 1 NO + 1 NC |
| Irms rated making capacity | 5090 A at 440 V |
| Coil technology | Built-in bidirectional peak limiting |
| Safety reliability level | B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Mechanical durability | 8 Mcycles |
| inrush power in VA (50/60 Hz, AC) | 965 VA |
| inrush power in W (DC) | 760 W |
| hold-in power consumption in VA (50/60 Hz, AC) | 17.6 VA |
| hold-in power consumption in W (DC) | 7.8 W |
| Operating time | 40...70 ms closing 15...50 ms opening |
| Maximum operating rate | 600 cyc/h AC-3 600 cyc/h AC-3e 300 cyc/h AC-1 |
| Connections - terminals | Power circuit: bar 2 - busbar cross section: 32 x 10 mm Power circuit: lugs-ring terminals 1 0.3 in2 (185 mm2) Control circuit: push-in 1 0.0003...0.004 in2 (0.2...2.5 mm2) - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.0004...0.004 in2 (0.25...2.5 mm2) - cable stiffness: flexible with cable end Control circuit: push-in 2 0.0008...0.002 in2 (0.5...1.0 mm2) with cable end Control circuit: push-in 0.001...0.004 in2 (0.75...2.5 mm2) - cable stiffness: solid stranded without cable end Control circuit: push-in 0.001...0.004 in2 (0.75...2.5 mm2) - cable stiffness: flexible with cable end |
| Connection pitch | 1.8 in (45 mm) |
| Mounting Support | Plate |
| Standards | EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 UL 60335-1 UL 60335-2-40:Annex JJ |
| Product Certifications | CB Scheme CCC cULus EAC CE UKCA EU-RO-MR by DNV-GL |
| Tightening torque | 309.8 lbf.in (35 N.m) |
| Height | 8.9 in (225 mm) |
| Width | 7.3 in (185 mm) |
| Depth | 8.9 in (226 mm) |
| Net Weight | 18.3 lb(US) (8.3 kg) |
| IP degree of protection | IP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106 |
|---|---|
| Ambient Air Temperature for Operation | -13...140 °F (-25...60 °C) |
| Ambient Air Temperature for Storage | -76...176 °F (-60...80 °C) |
| Mechanical robustness | Vibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed |
| color | Dark grey |
| Protective treatment | TH |
| Permissible ambient air temperature around the device | -40...158 °F (-40...70 °C) at Uc |
| Part number | LC1G4004EHEN |
|---|---|
| Type designation | LC1G |
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 3606481922083 |
| Warranty (in months) | 18 |
|---|
| Country of origin | CZ |
|---|---|
| Shipping weight | 8.3 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 29 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of LC1G is 550 A.
The rated operational voltage of LC1G is 48–130–DC V DC.
The tariff (HS) code on file for LC1G is 853650.
The EAN (GTIN) of LC1G is 3606481922083.
LC1G ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
Compare AC3 rating IEC contactors versus NEMA size codes, with cross-reference tables, derating formulas, and selection tips for engineers. Shop at Stoklink.
Master AC3 rating selection with our complete contactor checklist covering load sizing, utilization categories, derating, and coordination. Shop at Stoklink.