- Home
- All Collections
- Motor Protection Circuit Breakers (MPCB)
Motor Protection Circuit Breakers (MPCB)
Schneider Electric GV4P50N TeSys GV4 3P 50 A 50 kA Thermal-Magnetic Motor Protection Circuit Breaker (MPCB)
Schneider Electric GV4P50B TeSys GV4 3P 50 A 25 kA Thermal-Magnetic Motor Protection Circuit Breaker (MPCB)
Schneider Electric GV4P25N TeSys GV4 3P 25 A 50 kA Thermal-Magnetic Motor Protection Circuit Breaker (MPCB)
Schneider Electric GV4P12N TeSys GV4 3P 12.5 A 50 kA Thermal-Magnetic Motor Protection Circuit Breaker (MPCB)
Schneider Electric GV4P115S TeSys GV4 3P 115 A 100 kA Thermal-Magnetic Motor Protection Circuit Breaker (MPCB)
Schneider Electric GV4P115N TeSys GV4 3P 115 A 50 kA Thermal-Magnetic Motor Protection Circuit Breaker (MPCB)
Schneider Electric GV4P115B TeSys GV4 3P 115 A 25 kA Thermal-Magnetic Motor Protection Circuit Breaker (MPCB)
Schneider Electric GV4P07N TeSys GV4 3P 7 A 50 kA Thermal-Magnetic Motor Protection Circuit Breaker (MPCB)
Schneider Electric GV4P03N TeSys GV4 3P 3.5 A 50 kA Thermal-Magnetic Motor Protection Circuit Breaker (MPCB)
Schneider Electric GV4LE80N TeSys GV4 3P 80 A 50 kA Magnetic Motor Protection Circuit Breaker (MPCB)
Schneider Electric GV4LE50N TeSys GV4 3P 50 A 50 kA Magnetic Motor Protection Circuit Breaker (MPCB)
Schneider Electric GV4LE25N TeSys GV4 3P 25 A 50 kA Magnetic Motor Protection Circuit Breaker (MPCB)
Schneider Electric GV4LE12N TeSys GV4 3P 12.5 A 50 kA Magnetic Motor Protection Circuit Breaker (MPCB)
Schneider Electric GV4LE07N TeSys GV4 3P 7 A 50 kA Magnetic Motor Protection Circuit Breaker (MPCB)
Schneider Electric GV4LE03N TeSys GV4 3P 3.5 A 50 kA Magnetic Motor Protection Circuit Breaker (MPCB)
Schneider Electric GV4LE02N TeSys GV4 3P 2 A 50 kA Magnetic Motor Protection Circuit Breaker (MPCB)
Schneider Electric GV4L80N TeSys GV4 3P 80 A 50 kA Magnetic Motor Protection Circuit Breaker (MPCB)
Schneider Electric GV4L50N TeSys GV4 3P 50 A 50 kA Magnetic Motor Protection Circuit Breaker (MPCB)
Schneider Electric GV4L12N TeSys GV4 3P 12.5 A 50 kA Magnetic Motor Protection Circuit Breaker (MPCB)
Schneider Electric GV4L115N TeSys GV4 3P 115 A 50 kA Magnetic Motor Protection Circuit Breaker (MPCB)
Motor protection circuit breakers (MPCB) from ABB, Siemens and Schneider Electric combine short-circuit and overload protection for motor feeders. The range covers 0.16 A to 500 A in 3-pole versions, from small manual starters to large thermal-magnetic breakers. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Siemens SIRIUS 3RV2 and 3RV1 breakers, plus 3RN2 versions for motor protection with thermistor evaluation.
- Schneider Electric TeSys Deca GV2 and GV3 manual starters, TeSys GV4 thermal-magnetic breakers and Easy TeSys Power.
- ABB MS116, MS132 and MS165 manual motor starters and MO132 magnetic-only breakers.
- Accessories such as auxiliary contacts, busbar adapters and trip indicators for the 3RV1935 and GV2 families.
How to choose
- Setting range. The motor full-load current should sit inside the adjustable thermal band.
- Breaking capacity at the supply voltage, in kA, against the prospective short-circuit current.
- Thermal-magnetic or magnetic-only. Magnetic-only breakers need a separate overload relay.
- Coordination with the contactor, type 1 or type 2 under IEC 60947-4-1.
- Frame size and mounting: DIN rail or busbar system.
FAQ
What is the difference between an MPCB and an MCCB?
An MPCB is built around motor starting currents, with an adjustable thermal band and a magnetic trip set for inrush. An MCCB is a general feeder breaker with a wider rating scale.
Does an MPCB replace the overload relay?
Yes, when it has a thermal release. Magnetic-only types such as the ABB MO132 do not, so they need an overload relay downstream.
Do you export MPCBs outside Turkey?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.