Filter

Motor Protection Circuit Breakers (MPCB)

Filter
Showing 1 - 319 of 319 items

ABB 1SAM350000R1013 MS132-20 20A 3P 100kA Motor Protection Circuit Breaker

Reference No: 1SAM350000R1013
Catalog No: MS132-20
Rated Current (A): 20
Breaking Capacity (kA): (230 V AC) 100 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
165 pcs in stock
$47.55

ABB 1SAM350000R1003 MS132-0.4 0.25-0.40A 3P 100kA Motor Protection Circuit Breaker

Reference No: 1SAM350000R1003
Catalog No: MS132-0.4
Rated Current (A): 0.40
Breaking Capacity (kA): (230 V AC) 100 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
14 pcs in stock
$36.27

ABB 1SAM350000R1004 MS132-0.63 0.40-0.63A 3P 100kA Motor Protection Circuit Breaker

Reference No: 1SAM350000R1004
Catalog No: MS132-0.63
Rated Current (A): 0.63
Breaking Capacity (kA): (230 V AC) 100 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
32 pcs in stock
$36.27

ABB 1SAM250000R1015 MS116-32 32A 3P 10kA Motor Protection Circuit Breaker

Reference No: 1SAM250000R1015
Catalog No: MS116-32
Rated Current (A): 32
Breaking Capacity (kA): (230 V AC) 16 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
385 pcs in stock
$77.86

ABB 1SAM350000R1005 MS132-1.0 0.63-1.0A 3P 100kA 400V Motor Protection Circuit-Breaker

Reference No: 1SAM350000R1005
Catalog No: MS132-1.0
Rated Current (A): 1.0
Breaking Capacity (kA): (230 V AC) 100 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
20 pcs in stock
$36.27

ABB 1SAM350000R1001 MS132-0.16 3P 0.10-0.16A 100kA Motor Protection Circuit-Breaker

Reference No: 1SAM350000R1001
Catalog No: MS132-0.16
Rated Current (A): 0.16
Breaking Capacity (kA): (230 V AC) 100 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
40 pcs in stock
$38.21

ABB 1SAM350000R1002 MS132-0.25 0.16-0.25A 3P 100kA 400VAC Motor Protection Circuit Breaker

Reference No: 1SAM350000R1002
Catalog No: MS132-0.25
Rated Current (A): 0.25
Breaking Capacity (kA): (230 V AC) 100 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
42 pcs in stock
$38.21

ABB 1SAM250000R1013 MS116-20 20A 3P 10kA Motor Protection Circuit Breaker

Reference No: 1SAM250000R1013
Catalog No: MS116-20
Rated Current (A): 20
Breaking Capacity (kA): (230 V AC) 16 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
559 pcs in stock
$43.15

ABB 1SAM250000R1003 MS116-0.4 0.25-0.40A 3P 50kA Motor Protection Circuit-Breaker

Reference No: 1SAM250000R1003
Catalog No: MS116-0.4
Rated Current (A): 0.40
Breaking Capacity (kA): (230 V AC) 100 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
558 pcs in stock
$31.65

ABB 1SAM250000R1009 MS116-6.3 4.0-6.3A 3P 50kA 400VAC Motor Protection Circuit-Breaker

Reference No: 1SAM250000R1009
Catalog No: MS116-6.3
Rated Current (A): 6.3
Breaking Capacity (kA): (230 V AC) 75 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
1144 pcs in stock
$31.65

ABB 1SAM250000R1010 MS116-10 10A 3P 50kA 400VAC Motor Protection Circuit Breaker

Reference No: 1SAM250000R1010
Catalog No: MS116-10
Rated Current (A): 10
Breaking Capacity (kA): (230 V AC) 75 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
1905 pcs in stock
$34.01

ABB 1SAM250000R1008 MS116-4.0 2.5-4.0A 3P 50kA 400VAC Motor Protection Circuit-Breaker

Reference No: 1SAM250000R1008
Catalog No: MS116-4.0
Rated Current (A): 4.0
Breaking Capacity (kA): (230 V AC) 75 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
1928 pcs in stock
$31.65

ABB 1SAM250000R1011 MS116-16 16A 3P 16kA Motor Protection Circuit-Breaker

Reference No: 1SAM250000R1011
Catalog No: MS116-16
Rated Current (A): 16
Breaking Capacity (kA): (230 V AC) 16 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
936 pcs in stock
$38.42

ABB 1SAM250000R1005 MS116-1.0 0.63-1.0A 3P 50kA 400V Motor Protection Circuit Breaker

Reference No: 1SAM250000R1005
Catalog No: MS116-1.0
Rated Current (A): 1.0
Breaking Capacity (kA): (230 V AC) 100 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
631 pcs in stock
$31.65

ABB 1SAM250000R1006 MS116-1.6 1.0-1.6A 3P 50kA 400VAC Motor Protection Circuit-Breaker

Reference No: 1SAM250000R1006
Catalog No: MS116-1.6
Rated Current (A): 1.6
Breaking Capacity (kA): (230 V AC) 100 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
4028 pcs in stock
$31.65

ABB 1SAM250000R1007 MS116-2.5 1.6-2.5A 3P 50kA 400V Motor Protection Circuit-Breaker

Reference No: 1SAM250000R1007
Catalog No: MS116-2.5
Rated Current (A): 2.5
Breaking Capacity (kA): (230 V AC) 75 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
4768 pcs in stock
$31.65

ABB 1SAM250000R1004 MS116-0.63 0.40-0.63A 3P 50kA Motor Protection Circuit Breaker

Reference No: 1SAM250000R1004
Catalog No: MS116-0.63
Rated Current (A): 0.63
Breaking Capacity (kA): (230 V AC) 100 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
48 pcs in stock
$31.65

ABB 1SAM250000R1002 MS116-0.25 0.16-0.25A 3P 50kA 400VAC Motor Protection Circuit-Breaker

Reference No: 1SAM250000R1002
Catalog No: MS116-0.25
Rated Current (A): 0.25
Breaking Capacity (kA): (230 V AC) 100 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
877 pcs in stock
$33.43

ABB 1SAM250000R1001 MS116-0.16 0.10-0.16A 3P 50kA 400VAC Motor Protection Circuit-Breaker

Reference No: 1SAM250000R1001
Catalog No: MS116-0.16
Rated Current (A): 0.16
Breaking Capacity (kA): (230 V AC) 100 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
179 pcs in stock
$33.43

Motor protection circuit breakers (MPCB) from ABB, Siemens and Schneider Electric combine short-circuit and overload protection for motor feeders. The range covers 0.16 A to 500 A in 3-pole versions, from small manual starters to large thermal-magnetic breakers. Stoklink ships worldwide from Turkey and quotes project volumes on request.

What's in this range

  • Siemens SIRIUS 3RV2 and 3RV1 breakers, plus 3RN2 versions for motor protection with thermistor evaluation.
  • Schneider Electric TeSys Deca GV2 and GV3 manual starters, TeSys GV4 thermal-magnetic breakers and Easy TeSys Power.
  • ABB MS116, MS132 and MS165 manual motor starters and MO132 magnetic-only breakers.
  • Accessories such as auxiliary contacts, busbar adapters and trip indicators for the 3RV1935 and GV2 families.

How to choose

  • Setting range. The motor full-load current should sit inside the adjustable thermal band.
  • Breaking capacity at the supply voltage, in kA, against the prospective short-circuit current.
  • Thermal-magnetic or magnetic-only. Magnetic-only breakers need a separate overload relay.
  • Coordination with the contactor, type 1 or type 2 under IEC 60947-4-1.
  • Frame size and mounting: DIN rail or busbar system.

FAQ

What is the difference between an MPCB and an MCCB?

An MPCB is built around motor starting currents, with an adjustable thermal band and a magnetic trip set for inrush. An MCCB is a general feeder breaker with a wider rating scale.

Does an MPCB replace the overload relay?

Yes, when it has a thermal release. Magnetic-only types such as the ABB MO132 do not, so they need an overload relay downstream.

Do you export MPCBs outside Turkey?

Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.