- Home
- All Collections
- Motor Protection Circuit Breakers (MPCB)
Motor Protection Circuit Breakers (MPCB)
Schneider Electric GV2P16 GV2RT 3P 9-14A TeSys Deca Manual Starter and Protector
Schneider Electric GV2P14 GV2P 3-Pole 6-10A Manual Starter and Protector TeSys Deca
Schneider Electric GV2P10 GV2P 3-Pole 4-6.3A TeSys Deca Manual Starter and Protector
Schneider Electric GV2P08 GV2P 3-Pole 2.5-4A TeSys Deca Manual Starter and Protector
Schneider Electric GV2P07 GV2P 3-Pole 1.6-2.5A TeSys Deca Manual Starter and Protector
Schneider Electric GV2P06 GV2P 3-Pole 1-1.6A TeSys Deca Manual Motor Starter and Protector
Schneider Electric GV2P05 GV2P 3P 0.63-1A Motor Circuit Breaker TeSys GV2 Series
Schneider Electric GV2P04 GV2P 3-Pole 0.40-0.63A TeSys Deca Manual Starter and Protector
Schneider Electric GV2P03 GV2P 3P 0.25-0.40A TeSys Deca Manual Starter and Protector
Schneider Electric GV2P02 TeSys Deca GV2P 0.16-0.25 A Manual Starter and Protector
Schneider Electric GV2ME32 GV2P 3P 24-32A Manual Starter and Protector TeSys Deca
Schneider Electric GV2ME22 GV2ME 3-Pole 20-25A TeSys Deca Manual Starter and Protector
Schneider Electric GV2ME21 GV2ME 3P 17-23A Manual Motor Starter and Protector TeSys Deca
Schneider Electric GV2ME20 TeSys Deca 3P 13-18A Manual Starter and Protector
Schneider Electric GV2ME16 GV2ME 3P 9-14A Manual Motor Starter and Protector TeSys Deca
Schneider Electric GV2ME14 GV2ME 3-Pole 6-10A Manual Starter and Protector TeSys Deca
Schneider Electric GV2ME10 GV2ME 3P 4-6.3A Manual Starter and Protector TeSys Deca
Schneider Electric GV2ME08 GV2ME 3P 2.5-4A TeSys Deca Manual Motor Starter and Protector
Schneider Electric GV2ME07 GV2ME 3P 1.6-2.5A Manual Starter and Protector TeSys Deca
Schneider Electric GV2ME05 GV2ME 3-Pole 0.63-1A Manual Starter and Protector TeSys Deca
Motor protection circuit breakers (MPCB) from ABB, Siemens and Schneider Electric combine short-circuit and overload protection for motor feeders. The range covers 0.16 A to 500 A in 3-pole versions, from small manual starters to large thermal-magnetic breakers. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Siemens SIRIUS 3RV2 and 3RV1 breakers, plus 3RN2 versions for motor protection with thermistor evaluation.
- Schneider Electric TeSys Deca GV2 and GV3 manual starters, TeSys GV4 thermal-magnetic breakers and Easy TeSys Power.
- ABB MS116, MS132 and MS165 manual motor starters and MO132 magnetic-only breakers.
- Accessories such as auxiliary contacts, busbar adapters and trip indicators for the 3RV1935 and GV2 families.
How to choose
- Setting range. The motor full-load current should sit inside the adjustable thermal band.
- Breaking capacity at the supply voltage, in kA, against the prospective short-circuit current.
- Thermal-magnetic or magnetic-only. Magnetic-only breakers need a separate overload relay.
- Coordination with the contactor, type 1 or type 2 under IEC 60947-4-1.
- Frame size and mounting: DIN rail or busbar system.
FAQ
What is the difference between an MPCB and an MCCB?
An MPCB is built around motor starting currents, with an adjustable thermal band and a magnetic trip set for inrush. An MCCB is a general feeder breaker with a wider rating scale.
Does an MPCB replace the overload relay?
Yes, when it has a thermal release. Magnetic-only types such as the ABB MO132 do not, so they need an overload relay downstream.
Do you export MPCBs outside Turkey?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.