- Home
- All Collections
- Motor Control & Protection
Motor Control & Protection
Motor Control & Protection Categories
Motor Control & Protection
Siemens 1FL6022-2AF21-1AA1 SIMOTICS S-1FL6 Servo Motor 0.05 kW 230 V 3000 rpm IP65
Siemens 1FL2310-6AC01-0HB0 SIMOTICS S-1FL2 Servo Motor 7kW 33.4Nm 400V 3AC
Siemens 1FL2310-4AC01-0HB0 SIMOTICS S-1FL2 Servomotor 5kW 2000rpm 400V Servo Motor
Siemens 1FL2310-2AC01-0HB0 SIMOTICS S-1FL2 3.5kW 2000rpm 16.7Nm Servo Motor
Siemens 1FL2310-0AC01-0HB0 SIMOTICS S-1FL2 Servo Motor 2.5kW 11.9Nm 400V 3AC
Siemens 1FL2205-4AF01-0HB0 SIMOTICS S-1FL2 400V 1.5kW 3000rpm Servo Motor
Siemens 1FL2204-4AG00-0HC0 SIMOTICS S-1FL2 200V 1.00kW Servo Motor
Siemens 1FL2204-4AF00-0HC0 SIMOTICS S-1FL2 Servomotor 1kW 3000rpm IP54 Servo Motor
Siemens 1FL2204-2AG00-0HC0 SIMOTICS S-1FL2 Servomotor 0.75kW 3000rpm 200V Servo Motor
Siemens 1FL2204-2AF00-0HC0 SIMOTICS S-1FL2 0.75kW 3000rpm 2.4Nm Servo Motor
Siemens 1FL2203-4AG00-0HC0 SIMOTICS S-1FL2 Servomotor 400W 3000rpm 200V Servo Motor
Siemens 1FL2203-4AF00-0HC0 SIMOTICS S-1FL2 400V 0.40kW Servo Motor
Siemens 1FL2203-2AG00-0HC0 SIMOTICS S-1FL2 Servomotor 200W 3000rpm 200V Servo Motor
Siemens 1FL2203-2AF00-0HC0 SIMOTICS S-1FL2 200V 0.20kW Servo Motor
Siemens 1FL2105-4AF01-0HB0 SIMOTICS S-1FL2 400V 2.10kW Servo Motor
Siemens 1FL2102-4AG00-0HC0 SIMOTICS S-1FL2 Servomotor 100W 3000rpm 200V Servo Motor
Siemens 1FL2102-4AF00-0HC0 SIMOTICS S-1FL2 100W 400V 3000 rpm Servo Motor
Siemens 1FL2102-2AG00-0HC0 SIMOTICS S-1FL2 50W 200V 3000 rpm Servo Motor
Siemens 1FL2102-2AF00-0HC0 SIMOTICS S-1FL2 Servomotor 400V 50W 3000rpm 0.16Nm Servo Motor
Siemens 1FK2210-4AC00-0SA0 SIMOTICS S-1FK2 1FK2-CT 40 Nm 6.4 kW Servo Motor
Motor control and protection equipment from ABB, Siemens and Schneider Electric covers everything between the supply and the motor shaft. The range spans contactors, overload relays, motor protection circuit breakers, starters, soft starters, variable frequency drives, servo systems and industrial motors, with rated currents from 0.1 A to 2,650 A and power up to 800 kW. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Contactors – switching devices for motor and load circuits, mostly 3-pole
- Thermal Overload Relays – bimetal and electronic relays for motor overload protection
- Motor Protection Circuit Breakers (MPCB) – short-circuit and overload protection in one device
- Motor Starters & Motor Management – starter combinations and motor controllers such as TeSys U and SIRIUS 3RK
- Soft Starters – controlled ramp-up for 3-phase motors
- Variable Frequency Drives (VFD) – speed control with ABB ACS, Schneider Altivar and Siemens SINAMICS
- Servo Drives & Motion Control – servo motors, drives, controllers and cables
- Industrial Motors – SIMOTICS asynchronous motors
How to choose
- Motor power and rated current at the supply voltage. Size the starter or drive for the nameplate current, not just the kW value.
- Starting method: direct on line, soft start or variable speed. This decides whether you need a contactor, a soft starter or a VFD.
- Duty class, for example AC-3 for squirrel-cage motors under IEC 60947-4-1.
- Protection split: overload relay plus fuses or MCB, or a single MPCB.
- Control interface: coil voltage, fieldbus such as PROFINET, and mounting.
FAQ
What is the difference between a soft starter and a VFD?
A soft starter limits inrush current during start and stop at fixed supply frequency. A VFD changes the output frequency, so it also controls speed while running.
Do I need a contactor and an overload relay, or an MPCB?
An MPCB combines short-circuit and overload protection and works with a contactor. The separate route uses a fuse or MCB, a contactor and an overload relay. Choose by space, coordination type and rating.
Can you ship motor control products outside Turkey?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.