- Home
- All Collections
- Molded Case Circuit Breakers (MCCB)
Molded Case Circuit Breakers (MCCB)
Schneider Electric C25H3TM200 ComPacT NSX250H 3P 200 A 70 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C25H3MA220 ComPacT NSX250H 3P 220 A 70 kA MA Fixed Moulded Case Circuit Breaker
Schneider Electric C16S2TM125 ComPacT NSX160S 2P 125 A 70 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C16N6TM125 ComPacT NSX160N 4P 125 A 50 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C16N3MA150 ComPacT NSX160N 3P 150 A 50 kA MA Fixed Moulded Case Circuit Breaker
Schneider Electric C16M2TM160 ComPacT NSX160M 2P 160 A 25 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C16M2TM125 ComPacT NSX160M 2P 125 A 25 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C16M1TM160 ComPacT NSX160M 1P 160 A 40 kA at 240 V TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C16H6TM160 ComPacT NSX160H 4P 160 A 70 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C16H3TM160 ComPacT NSX160H 3P 160 A 70 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C16H3TM125 ComPacT NSX160H 3P 125 A 70 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C16H3MA150 ComPacT NSX160H 3P 150 A 70 kA MA Fixed Moulded Case Circuit Breaker
Schneider Electric C16F3MA150 ComPacT NSX160F 3P 150 A 36 kA MA Fixed Moulded Case Circuit Breaker
Schneider Electric C16F32D160 ComPacT NSX160F 3P 160 A 36 kA MicroLogic 2.2 Fixed Moulded Case Circuit Breaker
Schneider Electric C16F2TM160 ComPacT NSX160F 2P 160 A 18 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C16F2TM125 ComPacT NSX160F 2P 125 A 18 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C10W4TM100 ComPacT NSX100HB2 4P 100 A 100 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C10W3TM100 ComPacT NSX100HB2 3P 100 A 100 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C10W3TM080 ComPacT NSX100HB2 3P 80 A 100 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C10W3TM063 ComPacT NSX100HB2 3P 63 A 100 kA TM-D Fixed Moulded Case Circuit Breaker
Molded case circuit breakers (MCCB) from ABB, Schneider Electric and Siemens protect feeders, motors and distribution boards from about 10 A up to 1600 A. The range covers 3-pole and 4-pole breakers with fixed and adjustable trip units, with more than 1,800 products including accessories. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- ABB Tmax XT MCCBs – XT1 to XT7 frames with thermal-magnetic and Ekip electronic trip units.
- ABB Formula A MCCBs – A1 to A3 frames for general distribution.
- Schneider ComPacT NSX MCCBs – frames from 100 A to 630 A.
- Schneider ComPacT NS MCCBs – breakers from 630 A to 1600 A.
- Schneider GoPact MCCBs – compact breakers up to 800 A.
- Schneider EasyPact CVS MCCBs – CVS100 to CVS630 frames.
- Siemens SENTRON 3VA MCCBs – 3VA1 and 3VA2 breakers up to 1250 A.
- Siemens SENTRON 3VM MCCBs – 3VM1 breakers up to 630 A.
- MCCB Accessories, Releases & Trip Units – releases and trip units.
How to choose
- Frame size and rated current, with the trip unit set to the load current.
- Rated breaking capacity (Icu and Ics) at the system voltage, above the prospective short-circuit current.
- Trip unit: thermal-magnetic for simple feeders, electronic (LSI or LSIG) where selectivity is needed.
- Poles: 3P or 4P according to the neutral arrangement. Standard: IEC 60947-2.
FAQ
What is the difference between an MCCB and an ACB?
An MCCB is a compact molded-case breaker, typically used from tens of amperes to 1600 A. An ACB is a larger, often draw-out breaker for main incomers from 630 A upward.
What do Icu and Ics mean on an MCCB?
Icu is the ultimate breaking capacity. Ics is the service breaking capacity, the share of Icu after which the breaker stays fit for service.
Do you export MCCBs and their accessories?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.