- Home
- All Collections
- Molded Case Circuit Breakers (MCCB)
Molded Case Circuit Breakers (MCCB)
Schneider Electric C40W32D400 ComPacT NSX400HB2 3P 400 A 100 kA MicroLogic 2.3 Moulded Case Circuit Breaker
Schneider Electric C40V42D400 ComPacT NSX400HB1 4P 400 A 75 kA MicroLogic 2.3 Moulded Case Circuit Breaker
Schneider Electric C40V36E400 ComPacT NSX400HB1 3P 400 A 75 kA MicroLogic 6.3 E Moulded Case Circuit Breaker
Schneider Electric C40V35E400 ComPacT NSX400HB1 3P 400 A 75 kA MicroLogic 5.3 E Moulded Case Circuit Breaker
Schneider Electric C40R42D400 ComPacT NSX400R 4P 400 A 200 kA MicroLogic 2.3 Moulded Case Circuit Breaker
Schneider Electric C40R36E400 ComPacT NSX400R 3P 400 A 200 kA MicroLogic 6.3 E Moulded Case Circuit Breaker
Schneider Electric C40R35E400 ComPacT NSX400R 3P 400 A 200 kA MicroLogic 5.3 E Moulded Case Circuit Breaker
Schneider Electric C40R32D400 ComPacT NSX400R 3P 400 A 200 kA MicroLogic 2.3 Moulded Case Circuit Breaker
Schneider Electric C40N32M320 ComPacT NSX400N 3P 320 A 50 kA MicroLogic 2.3 M Moulded Case Circuit Breaker
Schneider Electric C40N31M320 ComPacT NSX400N 3P 320 A 50 kA MicroLogic 1.3 M Moulded Case Circuit Breaker
Schneider Electric C40H42D400 ComPacT NSX400H 4P 400 A 70 kA MicroLogic 2.3 Fixed Moulded Case Circuit Breaker
Schneider Electric C40H32M320 ComPacT NSX400H 3P 320 A 70 kA MicroLogic 2.3 M Moulded Case Circuit Breaker
Schneider Electric C40H32D400 ComPacT NSX400H 3P 400 A 70 kA MicroLogic 2.3 Fixed Moulded Case Circuit Breaker
Schneider Electric C40H31M320 ComPacT NSX400H 3P 320 A 70 kA MicroLogic 1.3 M Moulded Case Circuit Breaker
Schneider Electric C40F32M320 ComPacT NSX400F 3P 320 A 36 kA MicroLogic 2.3 M Moulded Case Circuit Breaker
Schneider Electric C40F31M320 ComPacT NSX400F 3P 320 A 36 kA MicroLogic 1.3 M Moulded Case Circuit Breaker
Schneider Electric C25W4TM200 ComPacT NSX250HB2 4P 200 A 100 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C25W4TM125 ComPacT NSX250HB2 4P 125 A 100 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C25W3TM250 ComPacT NSX250HB2 3P 250 A 100 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C25W3TM200 ComPacT NSX250HB2 3P 200 A 100 kA TM-D Fixed Moulded Case Circuit Breaker
Molded case circuit breakers (MCCB) from ABB, Schneider Electric and Siemens protect feeders, motors and distribution boards from about 10 A up to 1600 A. The range covers 3-pole and 4-pole breakers with fixed and adjustable trip units, with more than 1,800 products including accessories. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- ABB Tmax XT MCCBs – XT1 to XT7 frames with thermal-magnetic and Ekip electronic trip units.
- ABB Formula A MCCBs – A1 to A3 frames for general distribution.
- Schneider ComPacT NSX MCCBs – frames from 100 A to 630 A.
- Schneider ComPacT NS MCCBs – breakers from 630 A to 1600 A.
- Schneider GoPact MCCBs – compact breakers up to 800 A.
- Schneider EasyPact CVS MCCBs – CVS100 to CVS630 frames.
- Siemens SENTRON 3VA MCCBs – 3VA1 and 3VA2 breakers up to 1250 A.
- Siemens SENTRON 3VM MCCBs – 3VM1 breakers up to 630 A.
- MCCB Accessories, Releases & Trip Units – releases and trip units.
How to choose
- Frame size and rated current, with the trip unit set to the load current.
- Rated breaking capacity (Icu and Ics) at the system voltage, above the prospective short-circuit current.
- Trip unit: thermal-magnetic for simple feeders, electronic (LSI or LSIG) where selectivity is needed.
- Poles: 3P or 4P according to the neutral arrangement. Standard: IEC 60947-2.
FAQ
What is the difference between an MCCB and an ACB?
An MCCB is a compact molded-case breaker, typically used from tens of amperes to 1600 A. An ACB is a larger, often draw-out breaker for main incomers from 630 A upward.
What do Icu and Ics mean on an MCCB?
Icu is the ultimate breaking capacity. Ics is the service breaking capacity, the share of Icu after which the breaker stays fit for service.
Do you export MCCBs and their accessories?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.