Switch Disconnectors & Transfer Switches
Switch Disconnectors & Transfer Switches Categories
Switch Disconnectors & Transfer Switches
Siemens 3KD9103-3 3KD9 Switch Disconnector
Siemens 3KD9103-1 3KD9 Switch Disconnector
Siemens 3KD5430-0RE20-0 3KD5 1600A 3P 10V Switch Disconnector
Siemens 3KD5430-0RE10-0 3KD5 1600A 3P 10V Switch Disconnector
Siemens 3KD5230-0RE20-0 3KD5 1250A 3P 10V Switch Disconnector
Siemens 3KD5230-0RE10-0 3KD5 1250A 3P 10V Switch Disconnector
Siemens 3KD5030-0RE20-0 3KD5 1000A 3P 10V Switch Disconnector
Siemens 3KD5030-0RE10-0 3KD5 1000A 3P 10V Switch Disconnector
Siemens 3KD4830-0QE20-0 3KD4 800A 3P 10V Switch Disconnector
Siemens 3KD4830-0QE10-0 3KD4 800A 3P 10V Switch Disconnector
Siemens 3KD4630-0QE10-0 3KD4 630A 3P 10V Switch Disconnector
Siemens 3KD4430-0QE20-0 3KD4 500A 3P 10V Switch Disconnector
Siemens 3KD4430-0QE10-0 3KD4 500A 3P 10V Switch Disconnector
Siemens 3KD4230-0PE20-0 3KD4 400A 3P 10V Switch Disconnector
Siemens 3KD4230-0PE10-0 3KD4 400A 3P 10V Switch Disconnector
Siemens 3KD4030-0PE20-0 3KD4 315A 3P 10V Switch Disconnector
Siemens 3KD4030-0PE10-0 3KD4 315A 3P 10V Switch Disconnector
Siemens 3KD3830-0PE20-0 3KD3 250A 3P 10V Switch Disconnector
Siemens 3KD3830-0PE10-0 3KD3 250A 3P 10V Switch Disconnector
Siemens 3KD3630-0PE20-0 3KD3 200A 3P 10V Switch Disconnector
Switch disconnectors and transfer switches from ABB, Siemens, Schneider Electric and Mersen, covering isolation, manual changeover, automatic transfer and cam switching from 6 A up to 3800 A. The range includes 1P to 4P devices, with 3P and 4P the most common. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Switch Disconnectors – load-break isolators for panels and machines, including handles, shafts and interlocks.
- Changeover Switches (Manual & Motorized) – select between two supplies, such as mains and generator.
- Automatic Transfer Switches (ATS) – controller-driven transfer, including TransferPacT and ABB OXB and OTM units.
- Cam Switches – Harmony K rotary switches for control, metering and small loads.
How to choose
- Rated current and utilization category. Match the AC-22 or AC-23 duty to the load, and size for the full load current.
- Pole count. Use 4P where the neutral must be switched, for example when changing between two sources.
- Voltage and short-circuit withstand. Check the rating against the fault level at the installation point.
- Control method. Manual operation suits most panels. Choose motorized or automatic transfer when the change must happen without an operator.
- Mounting. Pick DIN-rail, base, door-coupled or enclosed to fit the panel layout.
FAQ
What is the difference between a switch disconnector and a circuit breaker?
A switch disconnector isolates and switches load current but gives no overcurrent protection. A circuit breaker also trips on overload and short circuit, so a protective device is normally installed upstream of the switch.
When should I use an ATS instead of a manual changeover switch?
Use an ATS when the transfer must happen automatically after a mains failure, for example to a generator. A manual changeover switch needs an operator and suits sites where short outages are acceptable.
Do you ship outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and we quote project quantities on request.