- Home
- All Collections
- Power Contactors (AC-3)
Power Contactors (AC-3)
Schneider Electric LC1D18BL LC1D 3-Pole 18A 480V AC 10HP TeSys Deca Contactor
Schneider Electric LC1D18BD TeSys Deca 3-Pole 18A 24VDC Coil 10HP 480V AC Power Contactor
Schneider Electric LC1D18B7 TeSys D 3P 18A 7.5kW 24V AC Coil Power Contactor
Schneider Electric LC1D150M7 TeSys Deca 3-Pole 150A 480V AC 100HP Power Contactor
Schneider Electric LC1D150F7 TeSys Deca 3-Pole 150A 480V AC 100HP 100kA SCCR Contactor
Schneider Electric LC1D150BD TeSys Deca 3-Pole 150A 480V AC 24V DC Coil Power Contactor
Schneider Electric LC1D150B7 TeSys Deca 3-Pole 150A 480V AC 100HP Power Contactor
Schneider Electric LC1D12Q7 TeSys Deca Contactor 3P 3NO AC-3 12 A 380 V AC Coil Contactor
Schneider Electric LC1D12M7 TeSys Deca 3-Pole 12A 480V AC 7.5HP 100kA SCCR Contactor
Schneider Electric LC1D12FD TeSys Deca Contactor 3P 3NO AC-3 12 A 110 V DC Coil Contactor
Schneider Electric LC1D12F7 TeSys Deca 3-Pole 12A 480V AC Coil 7.5HP Power Contactor
Schneider Electric LC1D12E7 TeSys Deca 3-Pole 12A 480V AC 7.5HP Motor Contactor
Schneider Electric LC1D12D7 TeSys Deca Contactor 3P 3NO AC-3 12 A 42 V AC Coil Contactor
Schneider Electric LC1D12BL TeSys Deca LC1D 12 A 24 VDC 3-Pole Contactor
Schneider Electric LC1D12BD TeSys Deca 3-Pole 12A 480V AC 7.5HP 24VDC Coil Power Contactor
Schneider Electric LC1D12B7 TeSys Deca 3-Pole 12A 480V AC 7.5HP Contactor
Schneider Electric LC1D115M7 TeSys Deca 3P 115A 55kW AC-3 Contactor
Schneider Electric LC1D115F7 TeSys Deca 3-Pole 115A 75HP 480V AC Contactor
Schneider Electric LC1D115BD TeSys Deca 3-Pole 115A 75HP 480V AC 24VDC Coil Power Contactor
Schneider Electric LC1D09V7 TeSys Deca Contactor 3P 3NO AC-3 9 A 400 V AC Coil Contactor
Power contactors (AC-3) from ABB, Schneider Electric and Siemens start and stop three-phase motors and switch heavy loads. The range covers over 650 products from 6 A to 2650 A, with motor ratings from 2.2 kW to 450 kW, mostly in 3 and 4 pole versions. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- ABB AF Contactors – 3 and 4 pole AF series with wide-range AC/DC coils.
- Schneider TeSys Deca Contactors – the largest series here, from 9 A to 200 A.
- Schneider TeSys Giga Contactors – high-current frames from 115 A to 800 A.
- Schneider TeSys K Contactors – compact contactors for 6 A to 16 A.
- Schneider Easy TeSys Contactors – general-purpose contactors from 6 A to 630 A.
- Siemens SIRIUS 3RT2 Contactors and Siemens SIRIUS 3RT1 Contactors – SIRIUS frames from small to very large.
How to choose
- Motor power and current in AC-3 at your supply voltage. Do not size from the AC-1 value.
- Pole count: 3P for motors, 4P where the neutral is switched.
- Coil voltage and type, AC or DC, against the control supply.
- Short-circuit protection and overload relay matched to the contactor, following the manufacturer's coordination tables.
- Auxiliary contact needs and whether add-on blocks fit the frame.
FAQ
What does AC-3 mean on a contactor?
AC-3 is the IEC 60947-4-1 category for starting and stopping squirrel-cage motors. Ratings in AC-3 are usually lower than AC-1 for the same frame.
Can I replace a contactor with another brand?
Check rated current in AC-3, pole count, coil voltage and mounting dimensions. Auxiliary contacts and coordination with the overload relay must also match.
Do you ship contactors outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.