- Home
- All Collections
- Power Contactors (AC-3)
Power Contactors (AC-3)
Schneider Electric LC1D40AB7 TeSys D 3-Pole 40A 440V AC Contactor
Schneider Electric LC1D38Q7 TeSys Deca Contactor 3P 3NO AC-3 38 A 380 V AC Coil Contactor
Schneider Electric LC1D38M7 TeSys D 3-Pole 38A 440V AC Contactor
Schneider Electric LC1D38FD TeSys Deca Contactor 3P 3NO AC-3 38 A 110 V DC Coil Contactor
Schneider Electric LC1D38E7 TeSys D 3-Pole 38A 440V Coil AC Power Contactor
Schneider Electric LC1D38D7 TeSys Deca Contactor 3P 3NO AC-3 38 A 42 V AC Coil Contactor
Schneider Electric LC1D38BL TeSys Deca 3-Pole 38A 20HP 480VAC Coil 24VDC Contactor
Schneider Electric LC1D38B7 TeSys D 3P 38A 18.5kW AC-3 Coil 24V AC Contactor
Schneider Electric LC1D32V7 TeSys Deca Contactor 3P 3NO AC-3 32 A 400 V AC Coil Contactor
Schneider Electric LC1D32Q7 TeSys Deca 3-Pole 32A 480V AC 20HP Contactor
Schneider Electric LC1D32M7 TeSys Deca 3-Pole 32A 20HP 480V AC Coil 220V Contactor
Schneider Electric LC1D32FD TeSys Deca Contactor 3P 3NO AC-3 32 A 110 V DC Coil Contactor
Schneider Electric LC1D32F7 TeSys Deca 3-Pole 32A 480V AC Coil 20HP Power Contactor
Schneider Electric LC1D32ED TeSys Deca Contactor 3P 3NO AC-3 32 A 48 V DC Coil Contactor
Schneider Electric LC1D32E7 TeSys Deca 3-Pole 32A 480V AC 20HP 100kA SCCR Contactor
Schneider Electric LC1D32D7 TeSys Deca Contactor 3P 3NO AC-3 32 A 42 V AC Coil Contactor
Schneider Electric LC1D32BNE TeSys Deca Contactor 3P 3NO AC-3 32 A 24-60 V AC/DC Coil Contactor
Schneider Electric LC1D32BL TeSys Deca LC1D 32 A 15 kW 24 V DC Contactor
Schneider Electric LC1D32BD TeSys Deca 3-Pole 32A 480V AC 24VDC Coil 20HP Power Contactor
Schneider Electric LC1D32B7 TeSys Deca 3-Pole 32A 20HP 480V AC Contactor
Power contactors (AC-3) from ABB, Schneider Electric and Siemens start and stop three-phase motors and switch heavy loads. The range covers over 650 products from 6 A to 2650 A, with motor ratings from 2.2 kW to 450 kW, mostly in 3 and 4 pole versions. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- ABB AF Contactors – 3 and 4 pole AF series with wide-range AC/DC coils.
- Schneider TeSys Deca Contactors – the largest series here, from 9 A to 200 A.
- Schneider TeSys Giga Contactors – high-current frames from 115 A to 800 A.
- Schneider TeSys K Contactors – compact contactors for 6 A to 16 A.
- Schneider Easy TeSys Contactors – general-purpose contactors from 6 A to 630 A.
- Siemens SIRIUS 3RT2 Contactors and Siemens SIRIUS 3RT1 Contactors – SIRIUS frames from small to very large.
How to choose
- Motor power and current in AC-3 at your supply voltage. Do not size from the AC-1 value.
- Pole count: 3P for motors, 4P where the neutral is switched.
- Coil voltage and type, AC or DC, against the control supply.
- Short-circuit protection and overload relay matched to the contactor, following the manufacturer's coordination tables.
- Auxiliary contact needs and whether add-on blocks fit the frame.
FAQ
What does AC-3 mean on a contactor?
AC-3 is the IEC 60947-4-1 category for starting and stopping squirrel-cage motors. Ratings in AC-3 are usually lower than AC-1 for the same frame.
Can I replace a contactor with another brand?
Check rated current in AC-3, pole count, coil voltage and mounting dimensions. Auxiliary contacts and coordination with the overload relay must also match.
Do you ship contactors outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.