Power Contactors (AC-3)
Schneider Electric LC1E50B5 Easy TeSys Contactor 3P 3NO AC-3 50 A 24 V AC Coil Contactor
Schneider Electric LC1E500M7 Easy TeSys Control LC1E 500A 3P 400V 250kW Contactor
Schneider Electric LC1E40M5 Easy TeSys 3-Pole 40A 440V AC Contactor
Schneider Electric LC1E40B5 EasyPact TVS 3-Pole 40A 440V AC Contactor
Schneider Electric LC1E400M7 TeSys E 3-Pole 400A 440V AC Contactor
Schneider Electric LC1E40004M7 Easy TeSys Contactor 4P 4NO AC-1 60 A 220 V AC Coil Contactor
Schneider Electric LC1E3810M5 EasyPact TVS 3P 38A 440V AC Contactor
Schneider Electric LC1E3810B5 Easy TeSys 3-Pole 38A 440V AC Contactor
Schneider Electric LC1E3801M5 Easy TeSys 3-Pole 38A 440V AC Contactor
Schneider Electric LC1E3801BD Easy TeSys Control LC1E 38A 3P 400V 18.5kW Contactor
Schneider Electric LC1E38004M7 Easy TeSys Contactor 4P 4NO AC-1 50 A 220 V AC Coil Contactor
Schneider Electric LC1E3210M5 Easy TeSys 3-Pole 32A 440V AC Contactor
Schneider Electric LC1E3210BD Easy TeSys Control LC1E 32A 3P 400V 15kW Contactor
Schneider Electric LC1E3210B5 Easy TeSys Contactor 3P 3NO AC-3 32 A 15 kW 24 V AC Coil Contactor
Schneider Electric LC1E3201M5 EasyPact TVS 32A 3P 440V AC Contactor
Schneider Electric LC1E300M5 EasyPact TVS 3-Pole 300A AC Contactor
Schneider Electric LC1E2510M5 TeSys E 3-Pole 25A 440V AC Contactor
Schneider Electric LC1E2510BD Easy TeSys Control LC1E 3P 25A 24VDC Contactor
Schneider Electric LC1E2510B5 TeSys E 3-Pole 25A 440V AC Contactor
Schneider Electric LC1E250M5 Easy TeSys 3-Pole 250A 440V AC Power Contactor
Power contactors (AC-3) from ABB, Schneider Electric and Siemens start and stop three-phase motors and switch heavy loads. The range covers over 650 products from 6 A to 2650 A, with motor ratings from 2.2 kW to 450 kW, mostly in 3 and 4 pole versions. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- ABB AF Contactors – 3 and 4 pole AF series with wide-range AC/DC coils.
- Schneider TeSys Deca Contactors – the largest series here, from 9 A to 200 A.
- Schneider TeSys Giga Contactors – high-current frames from 115 A to 800 A.
- Schneider TeSys K Contactors – compact contactors for 6 A to 16 A.
- Schneider Easy TeSys Contactors – general-purpose contactors from 6 A to 630 A.
- Siemens SIRIUS 3RT2 Contactors and Siemens SIRIUS 3RT1 Contactors – SIRIUS frames from small to very large.
How to choose
- Motor power and current in AC-3 at your supply voltage. Do not size from the AC-1 value.
- Pole count: 3P for motors, 4P where the neutral is switched.
- Coil voltage and type, AC or DC, against the control supply.
- Short-circuit protection and overload relay matched to the contactor, following the manufacturer's coordination tables.
- Auxiliary contact needs and whether add-on blocks fit the frame.
FAQ
What does AC-3 mean on a contactor?
AC-3 is the IEC 60947-4-1 category for starting and stopping squirrel-cage motors. Ratings in AC-3 are usually lower than AC-1 for the same frame.
Can I replace a contactor with another brand?
Check rated current in AC-3, pole count, coil voltage and mounting dimensions. Auxiliary contacts and coordination with the overload relay must also match.
Do you ship contactors outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.