- Home
- All Collections
- Power Contactors (AC-3)
Power Contactors (AC-3)
Schneider Electric LC1D09Q7 TeSys Deca 9A 3-Pole 480V AC Coil 5HP Power Contactor
Schneider Electric LC1D09M7 TeSys Deca 9A 3-Pole 480V AC Coil 5HP Power Contactor
Schneider Electric LC1D09KUE TeSys Deca Contactor 3P 3NO AC-3 9 A 100-250 V AC/DC Coil Contactor
Schneider Electric LC1D09FD TeSys Deca Contactor 3P 3NO AC-3 9 A 110 V DC Coil Contactor
Schneider Electric LC1D09F7 TeSys Deca 3-Pole 9A 480V AC 5HP 100kA SCCR Contactor
Schneider Electric LC1D09ED TeSys Deca Contactor 3P 3NO AC-3 9 A 48 V DC Coil Contactor
Schneider Electric LC1D09E7 TeSys Deca 3-Pole 9A 480V AC Coil 5HP Power Contactor
Schneider Electric LC1D09D7 TeSys Deca Contactor 3P 3NO AC-3 9 A 42 V AC Coil Contactor
Schneider Electric LC1D09BL TeSys Deca 3-Pole 9A 480V AC 100kA Contactor
Schneider Electric LC1D09BD TeSys D 3P 9A 4kW 24VDC Coil AC-3 Power Contactor
Schneider Electric LC1D09B7 TeSys Deca 3-Pole 9A 480VAC Coil 24V AC-3 Motor Contactor
Schneider Electric LC1E95M5 TeSys E 3-Pole 95A 440V AC Contactor
Schneider Electric LC1E95B5 Easy TeSys Contactor 3P 3NO AC-3 95 A 24 V AC Coil Contactor
Schneider Electric LC1E95004M7 Easy TeSys Contactor 4P 4NO AC-1 125 A 220 V AC Coil Contactor
Schneider Electric LC1E80M5 TeSys E 3-Pole 80A 440V AC Contactor
Schneider Electric LC1E80004M7 Easy TeSys Contactor 4P 4NO AC-1 100 A 220 V AC Coil Contactor
Schneider Electric LC1E65M5 EasyPact TVS 3P 65A 440V AC Contactor
Schneider Electric LC1E65004M7 Easy TeSys Contactor 4P 4NO AC-1 80 A 220 V AC Coil Contactor
Schneider Electric LC1E630M7 Easy TeSys Control LC1E 630A 3P 400V 335kW Contactor
Schneider Electric LC1E50M5 Easy TeSys 3-Pole 50A 440V AC Contactor
Power contactors (AC-3) from ABB, Schneider Electric and Siemens start and stop three-phase motors and switch heavy loads. The range covers over 650 products from 6 A to 2650 A, with motor ratings from 2.2 kW to 450 kW, mostly in 3 and 4 pole versions. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- ABB AF Contactors – 3 and 4 pole AF series with wide-range AC/DC coils.
- Schneider TeSys Deca Contactors – the largest series here, from 9 A to 200 A.
- Schneider TeSys Giga Contactors – high-current frames from 115 A to 800 A.
- Schneider TeSys K Contactors – compact contactors for 6 A to 16 A.
- Schneider Easy TeSys Contactors – general-purpose contactors from 6 A to 630 A.
- Siemens SIRIUS 3RT2 Contactors and Siemens SIRIUS 3RT1 Contactors – SIRIUS frames from small to very large.
How to choose
- Motor power and current in AC-3 at your supply voltage. Do not size from the AC-1 value.
- Pole count: 3P for motors, 4P where the neutral is switched.
- Coil voltage and type, AC or DC, against the control supply.
- Short-circuit protection and overload relay matched to the contactor, following the manufacturer's coordination tables.
- Auxiliary contact needs and whether add-on blocks fit the frame.
FAQ
What does AC-3 mean on a contactor?
AC-3 is the IEC 60947-4-1 category for starting and stopping squirrel-cage motors. Ratings in AC-3 are usually lower than AC-1 for the same frame.
Can I replace a contactor with another brand?
Check rated current in AC-3, pole count, coil voltage and mounting dimensions. Auxiliary contacts and coordination with the overload relay must also match.
Do you ship contactors outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.