- Home
- All Collections
- Motor Control & Protection
Motor Control & Protection
Motor Control & Protection Categories
Motor Control & Protection
Siemens 6SL3210-1PE23-8UL0 SINAMICS G120 PM240-2 400V 18.5kW FSD VFD Power Module
Siemens 6SL3210-1PE23-3UL0 SINAMICS G120 PM240-2 15kW 400V IP20 VFD Power Module
Siemens 6SL3210-1PE22-7UL0 SINAMICS G120 PM240-2 11kW 400V IP20 VFD Power Module
Siemens 6SL3210-1PE21-4UL0 SINAMICS G120 PM240-2 5.5kW 400V IP20 VFD Power Module
Siemens 6SL3210-1PE21-1UL0 SINAMICS PM240-2 3AC 400V 4kW IP20 Power Module
Siemens 6SL3210-1PE18-0UL1 SINAMICS PM240-2 380-480V 3kW FSA IP20 VFD Power Module
Siemens 6SL3210-1PE16-1UL1 SINAMICS PM240-2 2.2kW 400V IP20 Power Module
Siemens 6SL3210-1PE14-3UL1 SINAMICS PM240-2 1.5kW/1.1kW 400V IP20 VFD Power Module
Siemens 6SL3210-1PE13-2UL1 SINAMICS PM240-2 FSA 1.1kW 380-480V IP20 VFD Power Module
Siemens 6SL3210-1PE12-3UL1 SINAMICS PM240-2 0.75kW 400V IP20 VFD Power Module
Siemens 6SL3210-1PE11-8UL1 SINAMICS PM240-2 0.55kW 400V IP20 VFD Power Module
Siemens 6SL3210-1PB21-8UL0 SINAMICS G120 PM240-2 FSC 4kW 230V VFD Power Module
Siemens 6SL3210-1PB21-4UL0 SINAMICS G120 PM240-2 FSC 3kW 230V VFD Power Module
Siemens 6SL3210-1PB21-0UL0 SINAMICS G120 PM240-2 1.5kW/2.2kW 200-240V VFD Power Module
Siemens 6SL3210-1PB17-4UL0 SINAMICS G120 PM240-2 IP20 FSB 230V 1.5kW VFD Power Module
Siemens 6SL3210-1PB15-5UL0 SINAMICS G120 PM240-2 FSB 1.1kW 230V VFD Power Module
Siemens 6SL3210-1PB13-8UL0 SINAMICS G120 PM240-2 FSA 0.75kW 230V VFD Power Module
Siemens 6SL3210-1PB13-0UL0 SINAMICS PM240-2 IP20 FSA 230V 0.55kW VFD Power Module
Siemens 6SL3201-2AD20-8VA0 SINAMICS V20 Braking Module 400V/230V VFD Braking Module
Siemens 6SL3054-4AG00-2AA0 SINAMICS SD Card 512 MB Empty VFD Memory Card
Motor control and protection equipment from ABB, Siemens and Schneider Electric covers everything between the supply and the motor shaft. The range spans contactors, overload relays, motor protection circuit breakers, starters, soft starters, variable frequency drives, servo systems and industrial motors, with rated currents from 0.1 A to 2,650 A and power up to 800 kW. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Contactors – switching devices for motor and load circuits, mostly 3-pole
- Thermal Overload Relays – bimetal and electronic relays for motor overload protection
- Motor Protection Circuit Breakers (MPCB) – short-circuit and overload protection in one device
- Motor Starters & Motor Management – starter combinations and motor controllers such as TeSys U and SIRIUS 3RK
- Soft Starters – controlled ramp-up for 3-phase motors
- Variable Frequency Drives (VFD) – speed control with ABB ACS, Schneider Altivar and Siemens SINAMICS
- Servo Drives & Motion Control – servo motors, drives, controllers and cables
- Industrial Motors – SIMOTICS asynchronous motors
How to choose
- Motor power and rated current at the supply voltage. Size the starter or drive for the nameplate current, not just the kW value.
- Starting method: direct on line, soft start or variable speed. This decides whether you need a contactor, a soft starter or a VFD.
- Duty class, for example AC-3 for squirrel-cage motors under IEC 60947-4-1.
- Protection split: overload relay plus fuses or MCB, or a single MPCB.
- Control interface: coil voltage, fieldbus such as PROFINET, and mounting.
FAQ
What is the difference between a soft starter and a VFD?
A soft starter limits inrush current during start and stop at fixed supply frequency. A VFD changes the output frequency, so it also controls speed while running.
Do I need a contactor and an overload relay, or an MPCB?
An MPCB combines short-circuit and overload protection and works with a contactor. The separate route uses a fuse or MCB, a contactor and an overload relay. Choose by space, coordination type and rating.
Can you ship motor control products outside Turkey?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.