Filter

Molded Case Circuit Breakers (MCCB)

DEMO
Filter
Showing 1 - 40 of 1818 items

ABB 1SDA104895R1 MOE XT6 220...250V AC/DC Motor Operator for Moulded Case Circuit Breaker

Reference No: 1SDA104895R1
Catalog No: MOE XT6 220...250V AC/DC
84 pcs in stock
$730.64

ABB 1SDA100396R1 XT5N 400 Ekip Dip LS/I In=400 4p F F 400A 4-Pole Fixed Moulded Case Circuit Breaker

Reference No: 1SDA100396R1
Catalog No: XT5N 400 Ekip Dip LS/I In=400 4p F F
Rated Current (A): 400
Breaking Capacity (kA): (400 V AC) 36 kA
Number of Poles: 4P
22 pcs in stock
$862.85

ABB 1SDA100491R1 XT5H 630 Ekip Dip LS/I In=630 3p F F 630A 3-Pole Fixed Moulded Case Circuit Breaker

Reference No: 1SDA100491R1
Catalog No: XT5H 630 Ekip Dip LS/I In=630 3p F F
Rated Current (A): 630
Breaking Capacity (kA): (400 V AC) 70 kA
Number of Poles: 3P
5 pcs in stock
$1,040.52

ABB 1SDA100719R1 XT6N 800 Ekip Dip LS/I In=800 3p F F 800A 3-Pole Fixed Moulded Case Circuit Breaker

Reference No: 1SDA100719R1
Catalog No: XT6N 800 Ekip Dip LS/I In=800 3p F F
Rated Current (A): 800
Breaking Capacity (kA): (400 V AC) 36 kA
Number of Poles: 3P
31 pcs in stock
$1,126.36

ABB 1SDA066433R1 AUX-C 2Q+1SY 250Vac/dc XT1...XT6 F/P Auxiliary Contact 2NO+1NO Slow-Action

Reference No: 1SDA066433R1
Catalog No: AUX-C 2Q+1SY 250Vac/dc XT1...XT6 F/P
Rated Voltage (VAC): 250 V AC/DC
96 pcs in stock
$54.59

ABB 1SDA068147R1 XT4N 250 Ekip Dip LS/I In=250A 4p F F 250A 4-Pole Fixed Moulded Case Circuit Breaker

Reference No: 1SDA068147R1
Catalog No: XT4N 250 Ekip Dip LS/I In=250A 4p F F
Rated Current (A): 250
Breaking Capacity (kA): (400 V AC) 36 kA
Number of Poles: 4P
19 pcs in stock
$466.35

ABB 1SDA100467R1 XT5S 630 Ekip Dip LS/I In=630 4p F F 630A 4-Pole Fixed Molded Case Circuit Breaker

Reference No: 1SDA100467R1
Catalog No: XT5S 630 Ekip Dip LS/I In=630 4p F F
Rated Current (A): 630
Breaking Capacity (kA): (400 V AC) 50 kA
Number of Poles: 4P
17 pcs in stock
$1,376.31

ABB 1SDA100397R1 XT5N 630 Ekip Dip LS/I In=630 4p F F 630A 4-Pole Fixed Moulded Case Circuit Breaker

Reference No: 1SDA100397R1
Catalog No: XT5N 630 Ekip Dip LS/I In=630 4p F F
Rated Current (A): 630
Breaking Capacity (kA): (400 V AC) 36 kA
Number of Poles: 4P
40 pcs in stock
$1,196.41

Schneider Electric LV540316 CVS400N 3P 400A 50kA Fixed Moulded Case Circuit Breaker

Reference No: LV540316
Rated Current (A): 400
Rated Voltage (VAC): 380/415 V AC
Number of Poles: 3P
7 pcs in stock
$576.67

ABB 1SDA100740R1 XT6S 800 TMA 800-8000 3p F F 800A 3-Pole Fixed 50kA Moulded Case Circuit Breaker

Reference No: 1SDA100740R1
Catalog No: XT6S 800 TMA 800-8000 3p F F
Rated Current (A): 800
Breaking Capacity (kA): (400 V AC) 50 kA
Number of Poles: 3P
17 pcs in stock
$1,148.08

ABB 1SDA100487R1 XT5H 630 TMA 630-6300 3p F F 630A 3-Pole Fixed Moulded Case Circuit Breaker

Reference No: 1SDA100487R1
Catalog No: XT5H 630 TMA 630-6300 3p F F
Rated Current (A): 630
Breaking Capacity (kA): (400 V AC) 70 kA
Number of Poles: 3P
3 pcs in stock
$958.43

ABB 1SDA100733R1 XT6N 1000 Ekip Dip LS/I In=1000 4p F F 1000A 4-Pole Fixed Moulded Case Circuit Breaker

Reference No: 1SDA100733R1
Catalog No: XT6N 1000 Ekip Dip LS/I In=1000 4p F F
Rated Current (A): 1000
Breaking Capacity (kA): (400 V AC) 36 kA
Number of Poles: 4P
21 pcs in stock
$2,112.00

Schneider Electric C125N420FM ComPacT NS1250N 4P 1250A 50kA Fixed Moulded Case Circuit Breaker

Reference No: C125N420FM
Rated Current (A): 1250
Rated Voltage (VAC): 415 V AC
Number of Poles: 4P
3 pcs in stock
$1,887.87

Schneider Electric C125N320FM ComPacT NS1250N 3P 1250A 50kA Fixed Moulded Case Circuit Breaker

Reference No: C125N320FM
Rated Current (A): 1250
Rated Voltage (VAC): 415 V AC
Number of Poles: 3P
23 pcs in stock
$2,219.07

ABB 1SDA101367R1 XT7S M 1000 Ekip Dip LS/I In1000A 3p F F Moulded Case Circuit Breaker

Reference No: 1SDA101367R1
Catalog No: XT7S M 1000 Ekip Dip LS/I In1000A 3p F F
Rated Current (A): 1000
Breaking Capacity (kA): (400 V AC) 50 kA
Number of Poles: 3P
12 pcs in stock
$1,848.46

ABB 1SDA100829R1 XT7S 1600 Ekip Dip LS/I In=1600A 3p F F Moulded Case Circuit Breaker

Reference No: 1SDA100829R1
Catalog No: XT7S 1600 Ekip Dip LS/I In=1600A 3p F F
Rated Current (A): 1600
Breaking Capacity (kA): (400 V AC) 50 kA
Number of Poles: 3P
61 pcs in stock
$2,404.18

Schneider Electric C100N420FM ComPacT NS1000N 4P 1000A 50kA Fixed Moulded Case Circuit Breaker

Reference No: C100N420FM
Rated Current (A): 1000
Rated Voltage (VAC): 415 V AC
Number of Poles: 4P
2 pcs in stock
$2,533.85

ABB 1SDA101369R1 XT7S M 1600 Ekip Dip LS/I In1600A 3p F F Moulded Case Circuit Breaker

Reference No: 1SDA101369R1
Catalog No: XT7S M 1600 Ekip Dip LS/I In1600A 3p F F
Rated Current (A): 1600
Breaking Capacity (kA): (400 V AC) 50 kA
Number of Poles: 3P
6 pcs in stock
$2,703.93

Schneider Electric C25F32D250 NSX250F 3-Pole 250A 36kA 415V ComPacT Molded Case Circuit Breaker

Reference No: C25F32D250
Rated Current (A): 250
Rated Voltage (VAC): 415 V AC
Number of Poles: 3P
4 pcs in stock
$428.77

ABB 1SDA066786R1 A2N 250 TMF 250-2500 3p F F 250A 3-Pole Fixed Molded Case Circuit Breaker

Reference No: 1SDA066786R1
Catalog No: A2N 250 TMF 250-2500 3p F F
Rated Current (A): 250
Breaking Capacity (kA): (400 V AC) 36 kA
Number of Poles: 3P
1091 pcs in stock
$147.74

Molded case circuit breakers (MCCB) from ABB, Schneider Electric and Siemens protect feeders, motors and distribution boards from about 10 A up to 1600 A. The range covers 3-pole and 4-pole breakers with fixed and adjustable trip units, with more than 1,800 products including accessories. Stoklink ships worldwide from Turkey and quotes project volumes on request.

What's in this range

How to choose

  • Frame size and rated current, with the trip unit set to the load current.
  • Rated breaking capacity (Icu and Ics) at the system voltage, above the prospective short-circuit current.
  • Trip unit: thermal-magnetic for simple feeders, electronic (LSI or LSIG) where selectivity is needed.
  • Poles: 3P or 4P according to the neutral arrangement. Standard: IEC 60947-2.

FAQ

What is the difference between an MCCB and an ACB?

An MCCB is a compact molded-case breaker, typically used from tens of amperes to 1600 A. An ACB is a larger, often draw-out breaker for main incomers from 630 A upward.

What do Icu and Ics mean on an MCCB?

Icu is the ultimate breaking capacity. Ics is the service breaking capacity, the share of Icu after which the breaker stays fit for service.

Do you export MCCBs and their accessories?

Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.