- Home
- All Collections
- Molded Case Circuit Breakers (MCCB)
Molded Case Circuit Breakers (MCCB)
ABB 1SDA100732R1 XT6N 800 Ekip Dip LS/I In=800 4p F F 800A 4-Pole Fixed Moulded Case Circuit Breaker
Schneider Electric G40N3A400 GoPact MCCB 3P 400A 50kA @ 415V AC Molded Case Circuit Breaker
ABB 1SDA100720R1 XT6N 1000 Ekip Dip LS/I In=1000 3p F F 1000A 3-Pole Fixed Moulded Case Circuit Breaker
Schneider Electric G80N3E800 GoPact MCCB 3P 800A 50kA Molded Case Circuit Breaker
Schneider Electric G20F3A160 GoPact MCCB 200 3P 160A 36kA 415V Molded Case Circuit Breaker
ABB 1SDA066784R1 A2N 250 TMF 200-2000 3p F F 200A 3-Pole Fixed Molded Case Circuit Breaker
ABB 1SDA100485R1 XT5H 400 TMA 400-4000 3p F F 400A 3-Pole Fixed Moulded Case Circuit Breaker
ABB 1SDA066460R1 MOD XT1-XT3 220...250V ac/dc Motor Operator for Tmax XT1-XT3 Circuit Breakers
ABB 1SDA100417R1 XT5S 630 TMA 630-6300 3p F F 630A 3-Pole Fixed Moulded Case Circuit Breaker
ABB 1SDA100753R1 XT6S 800 TMA 800-8000 4p F F InN=100%In 4-Pole 800A Fixed Moulded Case Circuit Breaker
ABB 1SDA100731R1 XT6N 800 TMA 800-8000 4p F F InN=100%In Moulded Case Circuit Breaker 800A 4P Fixed
Schneider Electric C080N350FM ComPacT NS800N 3P 800A 50kA Fixed Moulded Case Circuit Breaker
ABB 1SDA066782R1 A2N 250 TMF 160-1600 3p F F 3-Pole 160A Fixed Moulded Case Circuit Breaker
Schneider Electric C63F42D630 NSX630F 4P 630A 36kA 415V Molded Case Circuit Breaker
Schneider Electric LV563310 CVS630F EasyPact CVS 4P 630A 36kA Moulded Case Circuit Breaker
ABB 1SDA101117R1 XT7S 1600 Ekip Dip LS/I In=1600A 4p F F 4-Pole 1600A Fixed Moulded Case Circuit Breaker for Transformer Generator & Installation Protection
ABB 1SDA100424R1 XT5S 400 Ekip Dip LS/I In=400 3p F F Moulded Case Circuit Breaker 400A 3P Fixed 50kA
ABB 1SDA100466R1 XT5S 400 Ekip Dip LS/I In=400 4p F F 400A 4-Pole Fixed Power Circuit Breaker
ABB 1SDA068126R1 XT4N 250 Ekip Dip LS/I In=250A 3p F F Moulded Case Circuit Breaker 250A 3P Fixed
Schneider Electric C40N42D400 NSX400N 4P 400A 50kA Moulded Case Circuit Breaker
Molded case circuit breakers (MCCB) from ABB, Schneider Electric and Siemens protect feeders, motors and distribution boards from about 10 A up to 1600 A. The range covers 3-pole and 4-pole breakers with fixed and adjustable trip units, with more than 1,800 products including accessories. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- ABB Tmax XT MCCBs – XT1 to XT7 frames with thermal-magnetic and Ekip electronic trip units.
- ABB Formula A MCCBs – A1 to A3 frames for general distribution.
- Schneider ComPacT NSX MCCBs – frames from 100 A to 630 A.
- Schneider ComPacT NS MCCBs – breakers from 630 A to 1600 A.
- Schneider GoPact MCCBs – compact breakers up to 800 A.
- Schneider EasyPact CVS MCCBs – CVS100 to CVS630 frames.
- Siemens SENTRON 3VA MCCBs – 3VA1 and 3VA2 breakers up to 1250 A.
- Siemens SENTRON 3VM MCCBs – 3VM1 breakers up to 630 A.
- MCCB Accessories, Releases & Trip Units – releases and trip units.
How to choose
- Frame size and rated current, with the trip unit set to the load current.
- Rated breaking capacity (Icu and Ics) at the system voltage, above the prospective short-circuit current.
- Trip unit: thermal-magnetic for simple feeders, electronic (LSI or LSIG) where selectivity is needed.
- Poles: 3P or 4P according to the neutral arrangement. Standard: IEC 60947-2.
FAQ
What is the difference between an MCCB and an ACB?
An MCCB is a compact molded-case breaker, typically used from tens of amperes to 1600 A. An ACB is a larger, often draw-out breaker for main incomers from 630 A upward.
What do Icu and Ics mean on an MCCB?
Icu is the ultimate breaking capacity. Ics is the service breaking capacity, the share of Icu after which the breaker stays fit for service.
Do you export MCCBs and their accessories?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.