- Home
- All Collections
- Power Contactors (AC-3)
Power Contactors (AC-3)
Schneider Electric LC1E0901M5 EasyPact TVS 3P 9A 440V AC Contactor
Schneider Electric LC1E0901BD Easy TeSys Control LC1E 3P 9A 24VDC Contactor
Schneider Electric LC1E0901B5 Easy TeSys Contactor 3P 3NO AC-3 9 A 4 kW 24 V AC Coil Contactor
Schneider Electric LC1E0610M5 Easy TeSys 3-Pole 6A 440V AC Contactor
Schneider Electric LC1E0610BD Easy TeSys Control LC1E 3P 6A 24VDC Contactor
Schneider Electric LC1E0610B5 Easy TeSys Contactor 3P 3NO AC-3 6 A 2.2 kW 24 V AC Coil Contactor
Schneider Electric LC1E0601M5 TeSys E 3-Pole 6A 440V AC Contactor
Schneider Electric LC1E0601BD Easy TeSys Control LC1E 3P 6A 24VDC Contactor
Schneider Electric A9C22813 iCT 3-Pole 16A 220-240V AC Contactor
Schneider Electric A9C22715 iCT 16A 230-240V AC Contactor
Schneider Electric A9C22712 iCT 16A 230-240V AC Contactor
Schneider Electric A9C22711 iCT 16A 230-240V AC Acti9 Contactor
Schneider Electric A9C20843 iCT 3-Pole 40A 220-240V AC Contactor
Schneider Electric A9C20842 iCT 2-Pole 40A 220-240V AC Contactor
Schneider Electric A9C20833 iCT 3-Pole 25A 220-240V AC Contactor Acti9
Schneider Electric A9C20732 iCT 25A 230-240V AC Contactor
Schneider Electric A9C20731 iCT 25A 230-240V AC Acti9 Contactor
ABB 1SBL351024R8000 UA50-30-00RA 220-230V 50Hz/230-240V 60Hz 3-Pole Contactor
ABB 1SBL281024R8010 UA30-30-10RA 220-230V 50Hz / 230-240V 60Hz 3-Pole Contactor
ABB 1SBL371024R8000 UA63-30-00RA 220-230V50Hz/230-240V60Hz 3-Pole Contactor
Power contactors (AC-3) from ABB, Schneider Electric and Siemens start and stop three-phase motors and switch heavy loads. The range covers over 650 products from 6 A to 2650 A, with motor ratings from 2.2 kW to 450 kW, mostly in 3 and 4 pole versions. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- ABB AF Contactors – 3 and 4 pole AF series with wide-range AC/DC coils.
- Schneider TeSys Deca Contactors – the largest series here, from 9 A to 200 A.
- Schneider TeSys Giga Contactors – high-current frames from 115 A to 800 A.
- Schneider TeSys K Contactors – compact contactors for 6 A to 16 A.
- Schneider Easy TeSys Contactors – general-purpose contactors from 6 A to 630 A.
- Siemens SIRIUS 3RT2 Contactors and Siemens SIRIUS 3RT1 Contactors – SIRIUS frames from small to very large.
How to choose
- Motor power and current in AC-3 at your supply voltage. Do not size from the AC-1 value.
- Pole count: 3P for motors, 4P where the neutral is switched.
- Coil voltage and type, AC or DC, against the control supply.
- Short-circuit protection and overload relay matched to the contactor, following the manufacturer's coordination tables.
- Auxiliary contact needs and whether add-on blocks fit the frame.
FAQ
What does AC-3 mean on a contactor?
AC-3 is the IEC 60947-4-1 category for starting and stopping squirrel-cage motors. Ratings in AC-3 are usually lower than AC-1 for the same frame.
Can I replace a contactor with another brand?
Check rated current in AC-3, pole count, coil voltage and mounting dimensions. Auxiliary contacts and coordination with the overload relay must also match.
Do you ship contactors outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.