Filter
Brand
Product Series
Rated Current (Amphere)
Brand
Product Series
Rated Current (Amphere)

Air Circuit Breakers (ACB)

Filter
Showing 1 - 60 of 404 items

ABB 1SDA071822R1 E4.2N 4000 Ekip Dip LSI 4p F HR 4000A 4P 66kA Air Circuit Breaker

Free Shipping
ABB 1SDA071822R1 E4.2N 4000 Ekip Dip LSI 4p F HR
Reference No: 1SDA071822R1
Catalog No: E4.2N 4000 Ekip Dip LSI 4p F HR
Rated Current (A): 4000 A
Breaking Capacity (kA): (400 V AC) 66 kA
Number of Poles: 4
1 pcs in stock
$9,071.23

ABB 1SDA066560R1 A3N 400 TMF 320-3200 3p F F 320A 3-Pole Fixed Air Circuit Breaker

Reference No: 1SDA066560R1
Catalog No: A3N 400 TMF 320-3200 3p F F
Rated Current (A): 320 A
Breaking Capacity (kA): (400 V AC) 36 kA
Number of Poles: 3
297 pcs in stock
$287.72

ABB 1SDA066547R1 A2N 250 TMF 250-2500 2p F F 250A 2-Pole Fixed Air Circuit Breaker

Reference No: 1SDA066547R1
Catalog No: A2N 250 TMF 250-2500 2p F F
Rated Current (A): 250 A
Breaking Capacity (kA): (400 V AC) 36 kA
Number of Poles: 2
38 pcs in stock
$121.14

ABB 1SDA074172R1 EKIP SUPPLY 110-240VAC/DC E1.2..E6.2-XT Power Supply Module

Reference No: 1SDA074172R1
Catalog No: EKIP SUPPLY 110-240VAC/DC E1.2..E6.2-XT
23 pcs in stock
$97.02

ABB 1SDA070821R1 E1.2B 1250 Ekip Dip LI 3p F F 1250A 3P 42kA Fixed Air Power Circuit Breaker

Free Shipping
ABB 1SDA070821R1 E1.2B 1250 Ekip Dip LI 3p F F Air Circuit Breakers
Reference No: 1SDA070821R1
Catalog No: E1.2B 1250 Ekip Dip LI 3p F F
Rated Current (A): 1250 A
Breaking Capacity (kA): (400 V AC) 42 kA
Number of Poles: 3
22 pcs in stock
$2,111.12

ABB 1SDA073909R1 E2.2 W FP Iu=2000 3p HR HR 2000A 3-Pole Withdrawable Chassis Part Power Circuit Breaker

Reference No: 1SDA073909R1
Catalog No: E2.2 W FP Iu=2000 3p HR HR
Rated Current (A): 2000 A
Number of Poles: 3
10 pcs in stock
$553.17

ABB 1SDA065523R1 ATS021 Automatic Transfer Switch Mutli Voltage Automatic Transfer Switch

Reference No: 1SDA065523R1
Catalog No: ATS021 Automatic Transfer Switch Mutli Voltage
15 pcs in stock
$986.95

ABB 1SDA070741R1 E1.2B 800 Ekip Dip LI 3p F F 800A 3P 42kA Fixed Power Circuit Breaker

Free Shipping
ABB 1SDA070741R1 E1.2B 800 Ekip Dip LI 3p F F Air Circuit Breakers
Reference No: 1SDA070741R1
Catalog No: E1.2B 800 Ekip Dip LI 3p F F
Rated Current (A): 800 A
Breaking Capacity (kA): (400 V AC) 42 kA
Number of Poles: 3
25 pcs in stock
$1,955.29

ABB 1SDA123475R1 AUX 6Q 400Vac E2.2...E6.2 F Auxiliary Contact Block

Reference No: 1SDA123475R1
Catalog No: AUX 6Q 400Vac E2.2...E6.2 F
0 pcs in stock
$143.97

ABB 1SDA065524R1 ATS022 AUTO.TRAN.SWITCH ADVANCED CONTROL Automatic Transfer Switch

Free Shipping
ABB 1SDA065524R1 ATS022 AUTO.TRAN.SWITCH ADVANCED CONTROL
Reference No: 1SDA065524R1
Catalog No: ATS022 AUTO.TRAN.SWITCH ADVANCED CONTROL
2 pcs in stock
$1,185.09

ABB 1SDA071142R1 E4.2N 3200 Ekip Dip LSI 3p F HR 3200A 3P 66kA Fixed Power Circuit Breaker

Free Shipping
ABB 1SDA071142R1 E4.2N 3200 Ekip Dip LSI 3p F HR
Reference No: 1SDA071142R1
Catalog No: E4.2N 3200 Ekip Dip LSI 3p F HR
Rated Current (A): 3200 A
Breaking Capacity (kA): (400 V AC) 66 kA
Number of Poles: 3
8 pcs in stock
$5,107.78

ABB 1SDA073906R1 Terminals term.box E1.2..E6.2-XT7/M 10pz SACE Emax 2 Terminal Box Accessory for Low-Voltage Circuit Breakers

Reference No: 1SDA073906R1
Catalog No: Terminals term.box E1.2..E6.2-XT7/M 10pz
5 pcs in stock
$73.87

ABB 1SDA071662R1 E2.2N 2000 Ekip Dip LSI 4p F HR 2000A 4P 66kA Air Circuit Breaker

Free Shipping
ABB 1SDA071662R1 E2.2N 2000 Ekip Dip LSI 4p F HR
Reference No: 1SDA071662R1
Catalog No: E2.2N 2000 Ekip Dip LSI 4p F HR
Rated Current (A): 2000 A
Breaking Capacity (kA): (400 V AC) 66 kA
Number of Poles: 4
13 pcs in stock
$4,478.02

ABB 1SDA070822R1 E1.2B 1250 Ekip Dip LSI 3p F F 1250A 3P 42kA Fixed Power Circuit Breaker

Free Shipping
ABB 1SDA070822R1 E1.2B 1250 Ekip Dip LSI 3p F F
Reference No: 1SDA070822R1
Catalog No: E1.2B 1250 Ekip Dip LSI 3p F F
Rated Current (A): 1250 A
Breaking Capacity (kA): (400 V AC) 42 kA
Number of Poles: 3
2 pcs in stock
$2,265.38

ABB 1SDA060204R1 T6S 630 TMA 630-6300 3p F F 630A 3-Pole Fixed Air Circuit Breaker

Free Shipping
ABB 1SDA060204R1 T6S 630 TMA 630-6300 3p F F
Reference No: 1SDA060204R1
Catalog No: T6S 630 TMA 630-6300 3p F F
Rated Current (A): 630 A
Breaking Capacity (kA): (400 V AC) 50 kA
Number of Poles: 3
0 pcs in stock
$1,673.05

ABB 1SDA072152R1 E1.2N 1000 Ekip Dip LSI 3p WMP 1000A 3P 66kA Withdrawable Power Circuit Breaker

Free Shipping
ABB 1SDA072152R1 E1.2N 1000 Ekip Dip LSI 3p WMP
Reference No: 1SDA072152R1
Catalog No: E1.2N 1000 Ekip Dip LSI 3p WMP
Rated Current (A): 1000 A
Breaking Capacity (kA): (400 V AC) 66 kA
Number of Poles: 3
2 pcs in stock
$2,549.57

ABB 1SDA068282R1 XT3S 250 MA200 Im=1200...2400 3p F F 200A 3-Pole Fixed Air Circuit Breaker

Reference No: 1SDA068282R1
Catalog No: XT3S 250 MA200 Im=1200...2400 3p F F
Rated Current (A): 200 A
Breaking Capacity (kA): (400 V AC) 50 kA
Number of Poles: 3
46 pcs in stock
$235.61

ABB 1SDA067093R1 XT2N 160 Ekip Dip LS/I In=100A 4p F F 4-Pole 100A Fixed Air Circuit Breaker

Reference No: 1SDA067093R1
Catalog No: XT2N 160 Ekip Dip LS/I In=100A 4p F F
Rated Current (A): 100 A
Breaking Capacity (kA): (400 V AC) 36 kA
Number of Poles: 4
2 pcs in stock
$420.33

ABB 1SDA070871R1 E1.2C 1600 Ekip Dip LI 3p F F 1600A 3P 50kA Fixed Power Circuit Breaker

Free Shipping
ABB 1SDA070871R1 E1.2C 1600 Ekip Dip LI 3p F F
Reference No: 1SDA070871R1
Catalog No: E1.2C 1600 Ekip Dip LI 3p F F
Rated Current (A): 1600 A
Breaking Capacity (kA): (400 V AC) 50 kA
Number of Poles: 3
53 pcs in stock
$2,513.59

ABB 1SDA067095R1 XT2N 160 Ekip Dip LS/I In=160A 4pFF InN=100% 4-Pole 160A Fixed Air Circuit Breaker

Reference No: 1SDA067095R1
Catalog No: XT2N 160 Ekip Dip LS/I In=160A 4pFF InN=100%
Rated Current (A): 160 A
Breaking Capacity (kA): (400 V AC) 36 kA
Number of Poles: 4
14 pcs in stock
$425.59

Air Circuit Breakers (ACB): Ultimate High-Capacity Protection up to ACB 4000A

Air Circuit Breakers (ACBs) are the backbone of electrical power distribution in large commercial, industrial, and utility applications. Serving as the primary protection device in main switchboards, the Air Circuit Breaker is engineered to manage and interrupt extremely high fault currents, often ranging up to 100kA or more. Known also simply as an Air Circuit Breaker, this device utilizes air as the arc-quenching medium, offering reliable safety for systems carrying massive load currents. At Stoklink, we supply top-tier industrial ACB units from world-class manufacturers, including the robust ABB Emax ACB, the sophisticated ACB Schneider MasterPact series, and the precision-engineered Siemens 3WL ACB.

Essential Industrial ACB Breaker Technology and Features

The structural integrity and advanced tripping mechanisms of the Air Circuit Breaker distinguish it from smaller protective devices. Unlike MCCBs, ACBs are typically designed to be modular and often withdrawable, allowing for easier maintenance, testing, and replacement without extended system downtime—a non-negotiable feature in high-power industrial environments.

Selecting ACB Breakers: Superior Current Ratings and Breaking Capacity up to ACB 4000A

The core strength of the ACB breaker lies in its massive current-handling capability. While moulded Case Circuit Breakers typically cap out around 1600A, Air Circuit Breakers routinely operate at higher nominal currents, ensuring protection for main incoming feeders. Stoklink offers a complete range of high-amperage Air Circuit Breaker options, supporting massive power demands. For extremely large facilities and main distribution points, the capacity can extend up to an impressive ACB 4000A or higher. This immense capacity, combined with very high short-circuit breaking capabilities, ensures that the breaker can safely and repeatedly interrupt severe electrical faults without damage to itself or the surrounding infrastructure. Selecting an ACB with a current rating that matches or exceeds peak operational demand is vital for system stability.

ACB vs MCCB Comparison: Choosing the Right Main Distribution Breaker

Understanding the distinction between an ACB vs MCCB is crucial in electrical system design. While both are used for overcurrent protection, they serve different operational tiers based on current and breaking capacity. moulded Case Circuit Breakers (MCCBs) handle intermediate currents and provide primary protection in sub-distribution boards or for large equipment feeders. They operate using fixed enclosures and generally employ thermal-magnetic or basic electronic trip units.

Air Circuit Breakers (ACBs), however, are deployed at the highest levels of the electrical network—at the point of power entry or primary busbar distribution. They manage much higher fault currents and nominal currents (up to 4000A or 6300A). ACBs always feature advanced electronic trip units, extensive connectivity options for energy management, and often utilize a robust, withdrawable design. If your requirement involves large-scale distribution or high fault currents, an Air Circuit Breaker is the necessary technology to protect your primary system.

Leading ACB Brands: ABB Emax ACB, Schneider MasterPact, and Siemens 3WL ACB Solutions

Global leaders in power management provide the most reliable ACB technology, each with signature features for distinct industrial requirements.

  • ABB Emax ACB: The ABB Emax ACB series, such as the Emax 2, is distinguished by its digital integration. These breakers go beyond protection, acting as smart power managers that monitor energy consumption and provide local and remote control, making them a crucial component for modern, connected industrial grids.

  • ACB Schneider MasterPact: The ACB Schneider MasterPact range, including the MasterPact MTZ series, is known for its advanced connectivity and digital modularity. Features often include embedded power meters and digital modules that allow for immediate upgrades and maintenance, enhancing operational flexibility and reducing maintenance complexity.

  • Siemens 3WL ACB: The Siemens 3WL ACB product family is engineered for flexibility and standardized integration across global applications. These breakers are known for their easy retrofitting capabilities and their comprehensive range of accessories and digital functionality, ensuring high performance and a compact footprint in switchgear assemblies.

Find ACB Breaker at Stoklink 

For mission-critical applications, large industrial plants, and main distribution infrastructure, the Air Circuit Breaker provides the definitive standard for high-capacity protection. Stoklink offers a superior range of ACB breaker products, supporting crucial functions and diverse current demands, including solutions up to ACB 4000A. Our inventory is backed by the innovation of ABB Emax ACB, the connectivity of ACB Schneider MasterPact, and the reliable engineering of Siemens 3WL ACB. You can also ensure the long-term resilience and safety of your most valuable electrical assets with Air Circuit Breaker collection at Stoklink.